CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure

The procedure of the device under HF heating and turbulent liquid cooling displacement analysis by means of existent program code is presented. The spatial computational cell size and other requirements ensuring the needed computational accuracy are formulated. In order to illustrate the procedure...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Вопросы атомной науки и техники
Datum:2006
Hauptverfasser: Zhelezov, S.A., Nazarenko, S.T., Porkhaev, V.V., Telnov, A.V.
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2006
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/78860
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure / S.A. Zhelezov, S.T. Nazarenko, V.V. Porkhaev, A.V. Telnov // Вопросы атомной науки и техники. — 2006. — № 2. — С. 103-105. — Бібліогр.: 2 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-78860
record_format dspace
spelling Zhelezov, S.A.
Nazarenko, S.T.
Porkhaev, V.V.
Telnov, A.V.
2015-03-22T08:38:35Z
2015-03-22T08:38:35Z
2006
CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure / S.A. Zhelezov, S.T. Nazarenko, V.V. Porkhaev, A.V. Telnov // Вопросы атомной науки и техники. — 2006. — № 2. — С. 103-105. — Бібліогр.: 2 назв. — англ.
1562-6016
PACS: 29.17.+w
https://nasplib.isofts.kiev.ua/handle/123456789/78860
The procedure of the device under HF heating and turbulent liquid cooling displacement analysis by means of existent program code is presented. The spatial computational cell size and other requirements ensuring the needed computational accuracy are formulated. In order to illustrate the procedure developed an example analysis of the Electron Resonance Accelerator of a mean beam power up to 300 kW cooling efficiency and deformation is provided.
Представлена методика подготовки заданий по расчету в существующих программных комплексах деформации конструкций, подверженных нагреву токами высокой частоты и охлаждению турбулентным течением жидкости. Определены требования к размеру пространственной счётной ячейки и другие условия, обеспечивающие необходимую точность расчётов. Приведен расчет эффективности охлаждения и деформаций корпуса электронного ускорителя непрерывного действия со средней мощностью пучка до 300 кВт, основанный на связанном анализе протекающих процессов и иллюстрирующий применение представленной методики.
Представлено методику підготовки завдань по розрахунку в діючих програмних комплексах деформації конструкцій, що схильні до нагріву струмами високої частоти та охолодженню турбулентною течією рідини. Визначені вимоги щодо розміру просторової розрахункової комірки та інші умови, що гарантують потрібну точність розрахунку. Приведено розрахунок ефективності охолоджування та деформації корпусу електронного прискорювача безперервної дії з середньою потужністю пучка до 300 кВт, оснований на зв’язаному аналізу перебігу процесів та ілюструючий застосування представленої методики.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Линейные ускорители заряженных частиц
CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure
Электронный ускоритель непрерывного действия. Методика подготовки заданий по расчету эффективности охлаждения и деформации резонатора
Електронний прискорювач безперервної дії. Методика підготовки завдань по розрахунку ефективності охолоджування та деформації резонатору
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure
spellingShingle CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure
Zhelezov, S.A.
Nazarenko, S.T.
Porkhaev, V.V.
Telnov, A.V.
Линейные ускорители заряженных частиц
title_short CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure
title_full CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure
title_fullStr CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure
title_full_unstemmed CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure
title_sort cw electron accelerator. resonator cooling efficiency and thermal strain coupled analysis procedure
author Zhelezov, S.A.
Nazarenko, S.T.
Porkhaev, V.V.
Telnov, A.V.
author_facet Zhelezov, S.A.
Nazarenko, S.T.
Porkhaev, V.V.
Telnov, A.V.
topic Линейные ускорители заряженных частиц
topic_facet Линейные ускорители заряженных частиц
publishDate 2006
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Электронный ускоритель непрерывного действия. Методика подготовки заданий по расчету эффективности охлаждения и деформации резонатора
Електронний прискорювач безперервної дії. Методика підготовки завдань по розрахунку ефективності охолоджування та деформації резонатору
description The procedure of the device under HF heating and turbulent liquid cooling displacement analysis by means of existent program code is presented. The spatial computational cell size and other requirements ensuring the needed computational accuracy are formulated. In order to illustrate the procedure developed an example analysis of the Electron Resonance Accelerator of a mean beam power up to 300 kW cooling efficiency and deformation is provided. Представлена методика подготовки заданий по расчету в существующих программных комплексах деформации конструкций, подверженных нагреву токами высокой частоты и охлаждению турбулентным течением жидкости. Определены требования к размеру пространственной счётной ячейки и другие условия, обеспечивающие необходимую точность расчётов. Приведен расчет эффективности охлаждения и деформаций корпуса электронного ускорителя непрерывного действия со средней мощностью пучка до 300 кВт, основанный на связанном анализе протекающих процессов и иллюстрирующий применение представленной методики. Представлено методику підготовки завдань по розрахунку в діючих програмних комплексах деформації конструкцій, що схильні до нагріву струмами високої частоти та охолодженню турбулентною течією рідини. Визначені вимоги щодо розміру просторової розрахункової комірки та інші умови, що гарантують потрібну точність розрахунку. Приведено розрахунок ефективності охолоджування та деформації корпусу електронного прискорювача безперервної дії з середньою потужністю пучка до 300 кВт, оснований на зв’язаному аналізу перебігу процесів та ілюструючий застосування представленої методики.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/78860
citation_txt CW electron accelerator. Resonator cooling efficiency and thermal strain coupled analysis procedure / S.A. Zhelezov, S.T. Nazarenko, V.V. Porkhaev, A.V. Telnov // Вопросы атомной науки и техники. — 2006. — № 2. — С. 103-105. — Бібліогр.: 2 назв. — англ.
work_keys_str_mv AT zhelezovsa cwelectronacceleratorresonatorcoolingefficiencyandthermalstraincoupledanalysisprocedure
AT nazarenkost cwelectronacceleratorresonatorcoolingefficiencyandthermalstraincoupledanalysisprocedure
AT porkhaevvv cwelectronacceleratorresonatorcoolingefficiencyandthermalstraincoupledanalysisprocedure
AT telnovav cwelectronacceleratorresonatorcoolingefficiencyandthermalstraincoupledanalysisprocedure
AT zhelezovsa élektronnyiuskoritelʹnepreryvnogodeistviâmetodikapodgotovkizadaniiporasčetuéffektivnostiohlaždeniâideformaciirezonatora
AT nazarenkost élektronnyiuskoritelʹnepreryvnogodeistviâmetodikapodgotovkizadaniiporasčetuéffektivnostiohlaždeniâideformaciirezonatora
AT porkhaevvv élektronnyiuskoritelʹnepreryvnogodeistviâmetodikapodgotovkizadaniiporasčetuéffektivnostiohlaždeniâideformaciirezonatora
AT telnovav élektronnyiuskoritelʹnepreryvnogodeistviâmetodikapodgotovkizadaniiporasčetuéffektivnostiohlaždeniâideformaciirezonatora
AT zhelezovsa elektronniipriskorûvačbezperervnoídíímetodikapídgotovkizavdanʹporozrahunkuefektivnostíoholodžuvannâtadeformacíírezonatoru
AT nazarenkost elektronniipriskorûvačbezperervnoídíímetodikapídgotovkizavdanʹporozrahunkuefektivnostíoholodžuvannâtadeformacíírezonatoru
AT porkhaevvv elektronniipriskorûvačbezperervnoídíímetodikapídgotovkizavdanʹporozrahunkuefektivnostíoholodžuvannâtadeformacíírezonatoru
AT telnovav elektronniipriskorûvačbezperervnoídíímetodikapídgotovkizavdanʹporozrahunkuefektivnostíoholodžuvannâtadeformacíírezonatoru
first_indexed 2025-11-24T11:37:29Z
last_indexed 2025-11-24T11:37:29Z
_version_ 1850845404923428864
fulltext CW ELECTRON ACCELERATOR. RESONATOR COOLING EFFICIEN- CY AND THERMAL STRAIN COUPLED ANALYSIS PROCEDURE S.A. Zhelezov, S.T. Nazarenko, V.V. Porkhaev, A.V. Telnov RNFC-VNIIEF 37 Mir ave., Sarov, Nizhniy Novgorod region, 607190, Russia E-mail: Zhelezov@expd.vniief.ru The procedure of the device under HF heating and turbulent liquid cooling displacement analysis by means of existent program code is presented. The spatial computational cell size and other requirements ensuring the needed computational accuracy are formulated. In order to illustrate the procedure developed an example analysis of the Electron Resonance Accelerator of a mean beam power up to 300 kW cooling efficiency and deformation is provid- ed. PACS: 29.17.+w INTRODUCTION To accelerate electrons in the resonator of the accel- erator developed by VNIIEF [1], proper electromagnetic oscillations with 100 MHz frequency are excited. Dissi- pative losses of high-frequency electromagnetic field (HF field) are related to induction of the high-frequency currents (HFC) in resonator walls. Under the action of currents the resonator walls are heated. This leads to displacement of the resonator case, violation of field distribution inside it, change of resonance frequency and decrease of Q-factor. Heat from the resonator walls is removed through washing of its outer surface by dem- ineralized water flow pumped through the channels of the cooling jacket. The described process is modeled by performing the coupled analysis cycle depicted in Fig.1. Fig.1. Coupled analysis cycle Heat flux distribution is calculated from the current distribution known on the basis of electromagnetic (EМ) analysis. Heat fluxes serve as loads in the thermal analysis. Temperatures calculated in the thermal analy- sis are transferred to the structural one. In the latter there are calculated coordinates of displaced geometry for the repeated EМ analysis. The proposed coupled analysis cycle is realized as a sequence of four calculation stages. Each stage is solved with the aid of common-purpose software available at VNIIEF. At the first stage, a problem of high-frequency elec- tromagnetic analysis of the accelerating structure is solved. The specific features of this calculation are pre- sented in ref. [1]. At the stage of the thermal analysis the cooling channel distribution over the model surface is optimized and the required film coefficients are estimated. Tem- perature field in the structure is calculated. During thermohydraulic analysis the parameters of cooling agent able to provide the required film coeffi- cients are calculated. In the structural analysis, the structure displacement due to its thermal expansion is determined. 1. THERMAL ANALYSIS Within the bounds of thermal analysis the problem of steady-state heat conduction is solved by means of fi- nite element technique. Heat fluxes of loss power serve as loads. Heat is removed through specifying the con- vection conditions for each cooled surface. In the course of a series of thermal analysis the film coefficients are selected. The goal is that the maximum temperature at any model point should not exceed the specified ulti- mate value Tmax. Heat fluxes are applied elementwise. The closest node of EM model is searched for each finite element of the heated surface. Basing upon the value of the surface current J in the node the mean heat flux per finite ele- ment is calculated: 2 2 3 4 0iq K K K J fτ π ρ µўў= (1) Here the factor K2 averages the value of sinusoidal signal over time; K3 takes into account resonator filling by radiofrequency power; K4 is the loss power safety factor. In order to check the adequacy of inter-model trans- lation of the heat load total loss power on the whole ap- plication surface is calculated. In the case of its signifi- cant deviation from the value known from the EM anal- ysis, the size of the finite element decreases, and the process of heat load application is repeated. 2. THERMOHYDRAULIC ANALYSIS The averaged parameters of the cooling agent pro- viding the film coefficients selected in the thermal anal- ysis are preliminarily estimated with the aid of the known empirical relations. For short we will name this type of calculation “thermohydraulic analysis – method 1”. In the course of the calculation series, among others, the initial flow rate and temperature of cooling agent are determined. These values are used as the initial conditions for refined thermo-hydrodynamic check-up of the developed design. ____________________________________________________________ PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY. 2006. № 2. Series: Nuclear Physics Investigations (46), p.103-105. 103 Surface Current Temperature Heat Flux Displacement Within the frames of the refined thermohydraulic analysis (“Method 2”) a thermo-hydrodynamic problem of the steady-state incompressible fluid flow is solved by the finite element technique. As a result of this solu- tion temperature distribution in both solid and hydrody- namic model areas as well as pressures and velocities in the hydrodynamic area are determined. The thermo-hydrodynamic problem is highly non- linear one. As the applied software provides the first or- der finite element only for hydrodynamic problem solv- ing, the accuracy of Nusselt number Nu computation is closely related to the discretization of the model bound- ary layer (Fig.2). For the thermo-hydrodynamic analysis of the accel- erator under development, discretization degree corre- sponding to Nu calculation accuracy not worse than 10% was selected. Fig.2. Influence of boundary layer thickness discretiza- tion on Nusselt number computation accuracy Eddy viscosity of cooling agent is calculated using a turbulence model SST [2], allowing rather an accurate computation of Nu within a wide range of Reynolds numbers. Fig.3. Oscillations of the absolute average values of de- gree of freedom PRES Decision on hydrodynamic problem completion is taken basing upon the magnitude of oscillation of the absolute average values of the degrees of freedom (DOF) less than 1% (Fig.3). 3. STRUCTURAL ANALYSIS Within the frames of the structural analysis the steady-state problem of thermal expansion is solved by the finite element technique. Nodal temperatures calcu- lated in the thermal analysis serve as the loads at this stage. If necessary, additional loads, for example, ambi- ent pressure, hydrodynamic pressure, gravity force etc. can be taken into account. The field of displacements calculated from the struc- tural analysis is output as a table and is available as ini- tial geometry in the repeated EM analysis. 4. PROCEDURE APPLICATION In conclusion, in order to illustrate the presented procedure application, let us present a typical computa- tion of cooling efficiency and displacements of one of the variants of the developed accelerator case. In this variant (Fig.4), the cooling agent (demineral- ized water) enters into the cooling jacket through the central pipe along the resonator axis and washes the case going through the annular cooling channel. Heat flux of the loss power is distributed along the resonator internal surface. Fig.4. Resonator problem sketch The heat load is calculated according to formula (1) and is shown in Fig.5 with arrows. Irregularity of heat load is almost four orders: the longest length of the ar- row corresponds to the heat flux of about 80 kW/m2 and the shortest one to that less than 14 W/m2. Fig.5. Heat flux distribution along the case The analysis has been performed using the cooling agent flow rate of 100 l/min. Water temperature at the entrance was 15°С. Additionally, ambient pressure of 1 atmosphere was taken into account. Calculation has shown that the cooling agent when passing the coolant loop will warm up by about 15°. The resonator case will warm up irregularly. The maxi- mum temperature will reach ~135ºC on the inner case __________________________________________________________ PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY. 2005. № 8. Series: Nuclear Physics Investigations (46), p.94-96. 94 surface in the vicinity of cross-section 2 (Fig.4). The minimal temperature will be ~16ºC on the horizontal symmetry plane in the vicinity of the smaller radius of the case. In this case the maximal axial displacement of the case will be about 1.5 mm, the diametric one – about 0.9 mm. The water temperature in the thin boundary layer in the vicinity of cross-section 2 reaches the boil- ing-point. Fig.6. Resonator case displacement The pressure difference required to ensure the pre- scribed flow rate is about 0.04 atm. The character of the case displacement under the action of the HF field loss power and atmospheric pressure is shown in Fig.6. CONCLUSION A procedure of related Thermo-Hydro-Structural analysis of the accelerator being developed by VNIIEF is proposed. A technique for translation of the surface current distribution to the distribution of heat fluxes is proposed. The dependence of the calculation of Nu cri- terion on the degree of discretization of the thermo-hy- draulic model boundary layer is found. To solve the de- veloped accelerator problems, a discretization degree is selected that corresponds to accuracy of hydrodynamic computation no worse than 10%. It is suggested that the turbulence model SST should be used for calculation of induced cooling fluid viscosity. It is suggested that the decision on the hydrodynamic problem completion should be made when the absolute average degree of freedom oscillation is less than 1%. Using the proposed calculation cycle is demonstrated by a practical example of Thermo-Hydro-Structural analysis of the developed accelerator resonator case. REFERENCES 1. N.V. Zavyalov et al. CW electron accelerator. De- sign and electro-physics characteristics // this issue, p.8-10. 2. F.R. Menter. Two-Equation Eddy-Viscosity Turbu- lence Models for Engineering Applications // AIAA Journal. 1994, v.32, p.1598-1605. ЭЛЕКТРОННЫЙ УСКОРИТЕЛЬ НЕПРЕРЫВНОГО ДЕЙСТВИЯ. МЕТОДИКА ПОДГОТОВКИ ЗА- ДАНИЙ ПО РАСЧЕТУ ЭФФЕКТИВНОСТИ ОХЛАЖДЕНИЯ И ДЕФОРМАЦИИ РЕЗОНАТОРА С.А. Железов, С.Т. Назаренко, В.В. Порхаев, А.В. Тельнов Представлена методика подготовки заданий по расчету в существующих программных комплексах де- формации конструкций, подверженных нагреву токами высокой частоты и охлаждению турбулентным тече- нием жидкости. Определены требования к размеру пространственной счётной ячейки и другие условия, обеспечивающие необходимую точность расчётов. Приведен расчет эффективности охлаждения и деформа- ций корпуса электронного ускорителя непрерывного действия со средней мощностью пучка до 300 кВт, основанный на связанном анализе протекающих процессов и иллюстрирующий применение представленной методики. ЕЛЕКТРОННИЙ ПРИСКОРЮВАЧ БЕЗПЕРЕРВНОЇ ДІЇ. МЕТОДИКА ПІДГОТОВКИ ЗАВДАНЬ ПО РОЗРАХУНКУ ЕФЕКТИВНОСТІ ОХОЛОДЖУВАННЯ ТА ДЕФОРМАЦІЇ РЕЗОНАТОРУ С.А. Жєлєзов, С.Т. Назарєнко, В.В. Порхаєв, А.В. Тєльнов Представлено методику підготовки завдань по розрахунку в діючих програмних комплексах деформації конструкцій, що схильні до нагріву струмами високої частоти та охолодженню турбулентною течією рідини. Визначені вимоги щодо розміру просторової розрахункової комірки та інші умови, що гарантують потрібну точність розрахунку. Приведено розрахунок ефективності охолоджування та деформації корпусу електронного прискорювача безперервної дії з середньою потужністю пучка до 300 кВт, оснований на зв’язаному аналізу перебігу процесів та ілюструючий застосування представленої методики. ____________________________________________________________ PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY. 2006. № 2. Series: Nuclear Physics Investigations (46), p.103-105. 103 ЭЛЕКТРОННЫЙ УСКОРИТЕЛЬ НЕПРЕРЫВНОГО ДЕЙСТВИЯ. МЕТОДИКА ПОДГОТОВКИ ЗАДАНИЙ ПО РАСЧЕТУ ЭФФЕКТИВНОСТИ ОХЛАЖДЕНИЯ И ДЕФОРМАЦИИ РЕЗОНАТОРА електронний прискорювач безперервної дії. методика підготовки завдань по розрахунку ефективності охолоджування та деформації резонатору