Full depletion voltage and separation voltage for a double-sided microstrip detector
The results of investigation of the full depletion and separation voltages are presented. It is shown that these voltages do not always have similar values. The explanation of this effect is suggested. Представлены результаты исследования напряжения полного обеднения и напряжения разделения. Показа...
Saved in:
| Published in: | Вопросы атомной науки и техники |
|---|---|
| Date: | 2006 |
| Main Authors: | , |
| Format: | Article |
| Language: | English |
| Published: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2006
|
| Subjects: | |
| Online Access: | https://nasplib.isofts.kiev.ua/handle/123456789/78861 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Cite this: | Full depletion voltage and separation voltage for a double-sided microstrip detector / N. Maslov, O. Starodubtsev // Вопросы атомной науки и техники. — 2006. — № 2. — С. 160-162. — Бібліогр.: 11 назв. — англ. |