Clipper circuit of pulse modulator used for Klystron-5045 power supply

While the operation of modulator to the pulsed transformer of klystron-5045, current through the primary winding of the pulse transformer (PT) continues to flow even upon the end of the klystron voltage operating pulse. This is determined by an energy stored in magnetizing inductance. The prolongati...

Full description

Saved in:
Bibliographic Details
Published in:Вопросы атомной науки и техники
Date:2001
ISSN:1562-6016
Main Authors: Akimov, A.V., Kazarezov, I.V.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2001
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/79017
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Clipper circuit of pulse modulator used for Klystron-5045 power supply / A.V. Akimov, I.V. Kazarezov // Вопросы атомной науки и техники. — 2001. — № 5. — С. 122-124. — Бібліогр.: 2 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
_version_ 1862711824085942272
author Akimov, A.V.
Kazarezov, I.V.
author_facet Akimov, A.V.
Kazarezov, I.V.
citation_txt Clipper circuit of pulse modulator used for Klystron-5045 power supply / A.V. Akimov, I.V. Kazarezov // Вопросы атомной науки и техники. — 2001. — № 5. — С. 122-124. — Бібліогр.: 2 назв. — англ.
collection DSpace DC
container_title Вопросы атомной науки и техники
description While the operation of modulator to the pulsed transformer of klystron-5045, current through the primary winding of the pulse transformer (PT) continues to flow even upon the end of the klystron voltage operating pulse. This is determined by an energy stored in magnetizing inductance. The prolongation of magnetizing current passing process simultaneously with the premature choking of thyratron can cause high voltage of inverse polarity at the klystron, which cause the destruction of the cathode. We have considered the possibility of shortening time of magnetizing current passage for the charge of reasonable choice of clipper circuit parameters. The behavior of clipper circuit was studied in modulators used for the VEPP-5 (BINP, Russia) preinjector klystron power supply. The optimum operation run of the circuit was selected and its design features are described.
first_indexed 2025-12-07T17:32:28Z
format Article
fulltext
id nasplib_isofts_kiev_ua-123456789-79017
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
issn 1562-6016
language English
last_indexed 2025-12-07T17:32:28Z
publishDate 2001
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
record_format dspace
spelling Akimov, A.V.
Kazarezov, I.V.
2015-03-24T17:28:19Z
2015-03-24T17:28:19Z
2001
Clipper circuit of pulse modulator used for Klystron-5045 power supply / A.V. Akimov, I.V. Kazarezov // Вопросы атомной науки и техники. — 2001. — № 5. — С. 122-124. — Бібліогр.: 2 назв. — англ.
1562-6016
PACS number: 29.17.+w
https://nasplib.isofts.kiev.ua/handle/123456789/79017
While the operation of modulator to the pulsed transformer of klystron-5045, current through the primary winding of the pulse transformer (PT) continues to flow even upon the end of the klystron voltage operating pulse. This is determined by an energy stored in magnetizing inductance. The prolongation of magnetizing current passing process simultaneously with the premature choking of thyratron can cause high voltage of inverse polarity at the klystron, which cause the destruction of the cathode. We have considered the possibility of shortening time of magnetizing current passage for the charge of reasonable choice of clipper circuit parameters. The behavior of clipper circuit was studied in modulators used for the VEPP-5 (BINP, Russia) preinjector klystron power supply. The optimum operation run of the circuit was selected and its design features are described.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Clipper circuit of pulse modulator used for Klystron-5045 power supply
Клипперная цепь импульсного модулятора, используемого для питания Клистрона 5045
Article
published earlier
spellingShingle Clipper circuit of pulse modulator used for Klystron-5045 power supply
Akimov, A.V.
Kazarezov, I.V.
title Clipper circuit of pulse modulator used for Klystron-5045 power supply
title_alt Клипперная цепь импульсного модулятора, используемого для питания Клистрона 5045
title_full Clipper circuit of pulse modulator used for Klystron-5045 power supply
title_fullStr Clipper circuit of pulse modulator used for Klystron-5045 power supply
title_full_unstemmed Clipper circuit of pulse modulator used for Klystron-5045 power supply
title_short Clipper circuit of pulse modulator used for Klystron-5045 power supply
title_sort clipper circuit of pulse modulator used for klystron-5045 power supply
url https://nasplib.isofts.kiev.ua/handle/123456789/79017
work_keys_str_mv AT akimovav clippercircuitofpulsemodulatorusedforklystron5045powersupply
AT kazarezoviv clippercircuitofpulsemodulatorusedforklystron5045powersupply
AT akimovav klippernaâcepʹimpulʹsnogomodulâtoraispolʹzuemogodlâpitaniâklistrona5045
AT kazarezoviv klippernaâcepʹimpulʹsnogomodulâtoraispolʹzuemogodlâpitaniâklistrona5045