A pulse transformer for a 10 MW klystron power supply

The design and test results of the Pulse Transformer (PT) for the klystron with a voltage of 120 kV, klystron current of 130 A and a pulse duration of 1.4 ms is presented. The PT design was realized with taking into account the following requirements: no edge effect on the secondary winding; no over...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Вопросы атомной науки и техники
Datum:2001
Hauptverfasser: Bak, P.A., Kazarezov, I.V., Kobets, V.V., Korepanov, A.A., Krainov, G.S., Radchenko, V.I., Severilo, V.S., Tuvik, A.A.
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2001
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/79018
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:A pulse transformer for a 10 MW klystron power supply / P.A. Bak, I.V. Kazarezov, V.V. Kobets, A.A. Korepanov, G.S. Krainov, V.I. Radchenko, V.S. Severilo, A.A. Tuvik // Вопросы атомной науки и техники. — 2001. — № 5. — С. 125-127. — Бібліогр.: 1 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-79018
record_format dspace
spelling Bak, P.A.
Kazarezov, I.V.
Kobets, V.V.
Korepanov, A.A.
Krainov, G.S.
Radchenko, V.I.
Severilo, V.S.
Tuvik, A.A.
2015-03-24T17:30:08Z
2015-03-24T17:30:08Z
2001
A pulse transformer for a 10 MW klystron power supply / P.A. Bak, I.V. Kazarezov, V.V. Kobets, A.A. Korepanov, G.S. Krainov, V.I. Radchenko, V.S. Severilo, A.A. Tuvik // Вопросы атомной науки и техники. — 2001. — № 5. — С. 125-127. — Бібліогр.: 1 назв. — англ.
1562-6016
PACS number: 29.17.+w
https://nasplib.isofts.kiev.ua/handle/123456789/79018
The design and test results of the Pulse Transformer (PT) for the klystron with a voltage of 120 kV, klystron current of 130 A and a pulse duration of 1.4 ms is presented. The PT design was realized with taking into account the following requirements: no edge effect on the secondary winding; no overvoltage along the secondary winding at the klystron breakdown; random high voltage breakdowns may occur only between metal parts, not on the windings; the sharp voltage edge applied to the primary winding should not cause a turn-to-turn overvoltage.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
A pulse transformer for a 10 MW klystron power supply
Импульсный трансформатор для питания 10 МВт-ного клистрона
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title A pulse transformer for a 10 MW klystron power supply
spellingShingle A pulse transformer for a 10 MW klystron power supply
Bak, P.A.
Kazarezov, I.V.
Kobets, V.V.
Korepanov, A.A.
Krainov, G.S.
Radchenko, V.I.
Severilo, V.S.
Tuvik, A.A.
title_short A pulse transformer for a 10 MW klystron power supply
title_full A pulse transformer for a 10 MW klystron power supply
title_fullStr A pulse transformer for a 10 MW klystron power supply
title_full_unstemmed A pulse transformer for a 10 MW klystron power supply
title_sort pulse transformer for a 10 mw klystron power supply
author Bak, P.A.
Kazarezov, I.V.
Kobets, V.V.
Korepanov, A.A.
Krainov, G.S.
Radchenko, V.I.
Severilo, V.S.
Tuvik, A.A.
author_facet Bak, P.A.
Kazarezov, I.V.
Kobets, V.V.
Korepanov, A.A.
Krainov, G.S.
Radchenko, V.I.
Severilo, V.S.
Tuvik, A.A.
publishDate 2001
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Импульсный трансформатор для питания 10 МВт-ного клистрона
description The design and test results of the Pulse Transformer (PT) for the klystron with a voltage of 120 kV, klystron current of 130 A and a pulse duration of 1.4 ms is presented. The PT design was realized with taking into account the following requirements: no edge effect on the secondary winding; no overvoltage along the secondary winding at the klystron breakdown; random high voltage breakdowns may occur only between metal parts, not on the windings; the sharp voltage edge applied to the primary winding should not cause a turn-to-turn overvoltage.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/79018
citation_txt A pulse transformer for a 10 MW klystron power supply / P.A. Bak, I.V. Kazarezov, V.V. Kobets, A.A. Korepanov, G.S. Krainov, V.I. Radchenko, V.S. Severilo, A.A. Tuvik // Вопросы атомной науки и техники. — 2001. — № 5. — С. 125-127. — Бібліогр.: 1 назв. — англ.
work_keys_str_mv AT bakpa apulsetransformerfora10mwklystronpowersupply
AT kazarezoviv apulsetransformerfora10mwklystronpowersupply
AT kobetsvv apulsetransformerfora10mwklystronpowersupply
AT korepanovaa apulsetransformerfora10mwklystronpowersupply
AT krainovgs apulsetransformerfora10mwklystronpowersupply
AT radchenkovi apulsetransformerfora10mwklystronpowersupply
AT severilovs apulsetransformerfora10mwklystronpowersupply
AT tuvikaa apulsetransformerfora10mwklystronpowersupply
AT bakpa impulʹsnyitransformatordlâpitaniâ10mvtnogoklistrona
AT kazarezoviv impulʹsnyitransformatordlâpitaniâ10mvtnogoklistrona
AT kobetsvv impulʹsnyitransformatordlâpitaniâ10mvtnogoklistrona
AT korepanovaa impulʹsnyitransformatordlâpitaniâ10mvtnogoklistrona
AT krainovgs impulʹsnyitransformatordlâpitaniâ10mvtnogoklistrona
AT radchenkovi impulʹsnyitransformatordlâpitaniâ10mvtnogoklistrona
AT severilovs impulʹsnyitransformatordlâpitaniâ10mvtnogoklistrona
AT tuvikaa impulʹsnyitransformatordlâpitaniâ10mvtnogoklistrona
AT bakpa pulsetransformerfora10mwklystronpowersupply
AT kazarezoviv pulsetransformerfora10mwklystronpowersupply
AT kobetsvv pulsetransformerfora10mwklystronpowersupply
AT korepanovaa pulsetransformerfora10mwklystronpowersupply
AT krainovgs pulsetransformerfora10mwklystronpowersupply
AT radchenkovi pulsetransformerfora10mwklystronpowersupply
AT severilovs pulsetransformerfora10mwklystronpowersupply
AT tuvikaa pulsetransformerfora10mwklystronpowersupply
first_indexed 2025-12-07T21:08:20Z
last_indexed 2025-12-07T21:08:20Z
_version_ 1850885224140898304