A new Krakow scanning nuclear microprobe: performance tests and early application experienc
A new scanning nuclear microprobe (MP) with a short-length probe forming system was designed, installed and tested at the 3MV Van de Graaff accelerator in Krakow. The MP resolution of 3.3mm was reached for a 2.4 MeV proton beam in the high-current mode (≥100pA). The MP facility provides a local, non...
Saved in:
| Published in: | Вопросы атомной науки и техники |
|---|---|
| Date: | 2001 |
| Main Authors: | , , , , , , |
| Format: | Article |
| Language: | English |
| Published: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2001
|
| Online Access: | https://nasplib.isofts.kiev.ua/handle/123456789/79241 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Cite this: | A new Krakow scanning nuclear microprobe: performance tests and early application experienc / S. Lebed, J. Lekki, M. Paszkowski, W. Polak, A. Potempa, Z. Stachura, J. Styczen // Вопросы атомной науки и техники. — 2001. — № 3. — С. 71-73. — Бібліогр.: 9 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| _version_ | 1862565044180484096 |
|---|---|
| author | Lebed, S. Lekki, J. Paszkowski, M. Polak, W. Potempa, A. Stachura, Z. Styczen, J. |
| author_facet | Lebed, S. Lekki, J. Paszkowski, M. Polak, W. Potempa, A. Stachura, Z. Styczen, J. |
| citation_txt | A new Krakow scanning nuclear microprobe: performance tests and early application experienc / S. Lebed, J. Lekki, M. Paszkowski, W. Polak, A. Potempa, Z. Stachura, J. Styczen // Вопросы атомной науки и техники. — 2001. — № 3. — С. 71-73. — Бібліогр.: 9 назв. — англ. |
| collection | DSpace DC |
| container_title | Вопросы атомной науки и техники |
| description | A new scanning nuclear microprobe (MP) with a short-length probe forming system was designed, installed and tested at the 3MV Van de Graaff accelerator in Krakow. The MP resolution of 3.3mm was reached for a 2.4 MeV proton beam in the high-current mode (≥100pA). The MP facility provides a local, non-destructive, quantitative elemental microanalysis using a Proton Induced X-ray Emission (PIXE) technique. As example of possible applications an analysis of a geological sample containing monazite crystals investigated by PIXE method is presented.
|
| first_indexed | 2025-11-25T23:52:34Z |
| format | Article |
| fulltext | |
| id | nasplib_isofts_kiev_ua-123456789-79241 |
| institution | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| issn | 1562-6016 |
| language | English |
| last_indexed | 2025-11-25T23:52:34Z |
| publishDate | 2001 |
| publisher | Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
| record_format | dspace |
| spelling | Lebed, S. Lekki, J. Paszkowski, M. Polak, W. Potempa, A. Stachura, Z. Styczen, J. 2015-03-30T07:34:07Z 2015-03-30T07:34:07Z 2001 A new Krakow scanning nuclear microprobe: performance tests and early application experienc / S. Lebed, J. Lekki, M. Paszkowski, W. Polak, A. Potempa, Z. Stachura, J. Styczen // Вопросы атомной науки и техники. — 2001. — № 3. — С. 71-73. — Бібліогр.: 9 назв. — англ. 1562-6016 PACS numbers: 29.27.Eg, 32.30.Rj, 91.65.Dt, 91.70.-c https://nasplib.isofts.kiev.ua/handle/123456789/79241 A new scanning nuclear microprobe (MP) with a short-length probe forming system was designed, installed and tested at the 3MV Van de Graaff accelerator in Krakow. The MP resolution of 3.3mm was reached for a 2.4 MeV proton beam in the high-current mode (≥100pA). The MP facility provides a local, non-destructive, quantitative elemental microanalysis using a Proton Induced X-ray Emission (PIXE) technique. As example of possible applications an analysis of a geological sample containing monazite crystals investigated by PIXE method is presented. The work has been supported by the State Committee of Scientific Research (KBN) in Poland (contract No.1438/IA/620/95) and the Ministry of Education and Science in Ukraine (contract No. 2M/289-99). en Національний науковий центр «Харківський фізико-технічний інститут» НАН України Вопросы атомной науки и техники A new Krakow scanning nuclear microprobe: performance tests and early application experienc Новый краковский сканирующий ядерный микрозонд: испытание в рабочих условиях и первый опыт применения Article published earlier |
| spellingShingle | A new Krakow scanning nuclear microprobe: performance tests and early application experienc Lebed, S. Lekki, J. Paszkowski, M. Polak, W. Potempa, A. Stachura, Z. Styczen, J. |
| title | A new Krakow scanning nuclear microprobe: performance tests and early application experienc |
| title_alt | Новый краковский сканирующий ядерный микрозонд: испытание в рабочих условиях и первый опыт применения |
| title_full | A new Krakow scanning nuclear microprobe: performance tests and early application experienc |
| title_fullStr | A new Krakow scanning nuclear microprobe: performance tests and early application experienc |
| title_full_unstemmed | A new Krakow scanning nuclear microprobe: performance tests and early application experienc |
| title_short | A new Krakow scanning nuclear microprobe: performance tests and early application experienc |
| title_sort | new krakow scanning nuclear microprobe: performance tests and early application experienc |
| url | https://nasplib.isofts.kiev.ua/handle/123456789/79241 |
| work_keys_str_mv | AT lebeds anewkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT lekkij anewkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT paszkowskim anewkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT polakw anewkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT potempaa anewkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT stachuraz anewkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT styczenj anewkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT lebeds novyikrakovskiiskaniruûŝiiâdernyimikrozondispytanievrabočihusloviâhipervyiopytprimeneniâ AT lekkij novyikrakovskiiskaniruûŝiiâdernyimikrozondispytanievrabočihusloviâhipervyiopytprimeneniâ AT paszkowskim novyikrakovskiiskaniruûŝiiâdernyimikrozondispytanievrabočihusloviâhipervyiopytprimeneniâ AT polakw novyikrakovskiiskaniruûŝiiâdernyimikrozondispytanievrabočihusloviâhipervyiopytprimeneniâ AT potempaa novyikrakovskiiskaniruûŝiiâdernyimikrozondispytanievrabočihusloviâhipervyiopytprimeneniâ AT stachuraz novyikrakovskiiskaniruûŝiiâdernyimikrozondispytanievrabočihusloviâhipervyiopytprimeneniâ AT styczenj novyikrakovskiiskaniruûŝiiâdernyimikrozondispytanievrabočihusloviâhipervyiopytprimeneniâ AT lebeds newkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT lekkij newkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT paszkowskim newkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT polakw newkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT potempaa newkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT stachuraz newkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc AT styczenj newkrakowscanningnuclearmicroprobeperformancetestsandearlyapplicationexperienc |