Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc

The constriction of an argon arc caused by electronegative and molecular impurities is considered at atmospheric pressure. It is shown that the presence of electronegative and molecular impurities leads to an additional diminution of sizes of field occupied by discharge. The action of molecular vapo...

Full description

Saved in:
Bibliographic Details
Published in:Вопросы атомной науки и техники
Date:2002
Main Author: Porytskyy, P.V.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2002
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/79278
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc / P.V. Porytskyy // Вопросы атомной науки и техники. — 2002. — № 5. — С. 130-132. — Бібліогр.: 7 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-79278
record_format dspace
spelling Porytskyy, P.V.
2015-03-30T09:18:50Z
2015-03-30T09:18:50Z
2002
Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc / P.V. Porytskyy // Вопросы атомной науки и техники. — 2002. — № 5. — С. 130-132. — Бібліогр.: 7 назв. — англ.
1562-6016
PACS: 52.80.-s
https://nasplib.isofts.kiev.ua/handle/123456789/79278
The constriction of an argon arc caused by electronegative and molecular impurities is considered at atmospheric pressure. It is shown that the presence of electronegative and molecular impurities leads to an additional diminution of sizes of field occupied by discharge. The action of molecular vapors and electronegative species causes also the split of arc column in the layers, which may be characterized by the different effective temperatures. Spatial characteristics of the arc are calculated and then ones are compared with experimental data.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Low temperature plasma and plasma technologies
Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc
spellingShingle Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc
Porytskyy, P.V.
Low temperature plasma and plasma technologies
title_short Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc
title_full Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc
title_fullStr Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc
title_full_unstemmed Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc
title_sort influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc
author Porytskyy, P.V.
author_facet Porytskyy, P.V.
topic Low temperature plasma and plasma technologies
topic_facet Low temperature plasma and plasma technologies
publishDate 2002
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
description The constriction of an argon arc caused by electronegative and molecular impurities is considered at atmospheric pressure. It is shown that the presence of electronegative and molecular impurities leads to an additional diminution of sizes of field occupied by discharge. The action of molecular vapors and electronegative species causes also the split of arc column in the layers, which may be characterized by the different effective temperatures. Spatial characteristics of the arc are calculated and then ones are compared with experimental data.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/79278
fulltext
citation_txt Influence of molecular and electronegative impurities on the contraction of the plasma column of an argon arc / P.V. Porytskyy // Вопросы атомной науки и техники. — 2002. — № 5. — С. 130-132. — Бібліогр.: 7 назв. — англ.
work_keys_str_mv AT porytskyypv influenceofmolecularandelectronegativeimpuritiesonthecontractionoftheplasmacolumnofanargonarc