Calculation of thermal transient condition in the biperiodic accelerating structure

RF power distribution as well as deformation and resonance frequency of the structure after stepped changing of RF power or cooling water temperature were investigated. Transient process is not exponential. Effective time constant corresponding to 90% level of resonant frequency is equal to 16/19 s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Вопросы атомной науки и техники
Datum:2004
1. Verfasser: Zavadtsev, D.A.
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2004
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/79353
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Calculation of thermal transient condition in the biperiodic accelerating structure / D.A. Zavadtsev // Вопросы атомной науки и техники. — 2004. — № 2. — С. 87-89. — Бібліогр.: 4 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-79353
record_format dspace
spelling Zavadtsev, D.A.
2015-03-31T14:16:54Z
2015-03-31T14:16:54Z
2004
Calculation of thermal transient condition in the biperiodic accelerating structure / D.A. Zavadtsev // Вопросы атомной науки и техники. — 2004. — № 2. — С. 87-89. — Бібліогр.: 4 назв. — англ.
1562-6016
PACS: 29.17.+w
https://nasplib.isofts.kiev.ua/handle/123456789/79353
RF power distribution as well as deformation and resonance frequency of the structure after stepped changing of RF power or cooling water temperature were investigated. Transient process is not exponential. Effective time constant corresponding to 90% level of resonant frequency is equal to 16/19 sec at power/temperature changing. Effective time constant corresponding to derivative value in the control region is equal to 11/21 sec at power/temperature changing.
Отримано часові залежності власної частоти прискорюючої структури при східчастій зміні потужності НВЧ втрат і зміні температури і потоку води. Процеси – не експонентні. Ефективна постійна часу, оцінена за рівнем частоти 0,9, дорівнює 16 с при зміні НВЧ потужності втрат і 19 с при зміні температури води, що протікає. Ефективна постійна часу, оцінена за значенням похідної в області регулювання, дорівнює 11 с при зміні НВЧ потужності втрат і 21 с при зміні температури води, що протікає.
Получены временные зависимости собственной частоты ускоряющей структуры при ступенчатом изменении мощности СВЧ потерь и изменении температуры и потока воды. Процессы – не экспоненциальные. Эффективная постоянная времени, оцененная по уровню частоты 0,9, равна 16 с при изменении СВЧ мощности потерь и 19 с при изменении температуры протекающей воды. Эффективная постоянная времени, оцененная по значению производной в области регулирования, равна 11 с при изменении СВЧ мощности потерь и 21 с при изменении температуры протекающей воды.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Элементы ускорителей
Calculation of thermal transient condition in the biperiodic accelerating structure
Розрахунок теплових перехідних режимів у біпериодичній прискорюючий структурі
Расчет тепловых переходных режимов в бипериодической ускоряющей структуре
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Calculation of thermal transient condition in the biperiodic accelerating structure
spellingShingle Calculation of thermal transient condition in the biperiodic accelerating structure
Zavadtsev, D.A.
Элементы ускорителей
title_short Calculation of thermal transient condition in the biperiodic accelerating structure
title_full Calculation of thermal transient condition in the biperiodic accelerating structure
title_fullStr Calculation of thermal transient condition in the biperiodic accelerating structure
title_full_unstemmed Calculation of thermal transient condition in the biperiodic accelerating structure
title_sort calculation of thermal transient condition in the biperiodic accelerating structure
author Zavadtsev, D.A.
author_facet Zavadtsev, D.A.
topic Элементы ускорителей
topic_facet Элементы ускорителей
publishDate 2004
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Розрахунок теплових перехідних режимів у біпериодичній прискорюючий структурі
Расчет тепловых переходных режимов в бипериодической ускоряющей структуре
description RF power distribution as well as deformation and resonance frequency of the structure after stepped changing of RF power or cooling water temperature were investigated. Transient process is not exponential. Effective time constant corresponding to 90% level of resonant frequency is equal to 16/19 sec at power/temperature changing. Effective time constant corresponding to derivative value in the control region is equal to 11/21 sec at power/temperature changing. Отримано часові залежності власної частоти прискорюючої структури при східчастій зміні потужності НВЧ втрат і зміні температури і потоку води. Процеси – не експонентні. Ефективна постійна часу, оцінена за рівнем частоти 0,9, дорівнює 16 с при зміні НВЧ потужності втрат і 19 с при зміні температури води, що протікає. Ефективна постійна часу, оцінена за значенням похідної в області регулювання, дорівнює 11 с при зміні НВЧ потужності втрат і 21 с при зміні температури води, що протікає. Получены временные зависимости собственной частоты ускоряющей структуры при ступенчатом изменении мощности СВЧ потерь и изменении температуры и потока воды. Процессы – не экспоненциальные. Эффективная постоянная времени, оцененная по уровню частоты 0,9, равна 16 с при изменении СВЧ мощности потерь и 19 с при изменении температуры протекающей воды. Эффективная постоянная времени, оцененная по значению производной в области регулирования, равна 11 с при изменении СВЧ мощности потерь и 21 с при изменении температуры протекающей воды.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/79353
citation_txt Calculation of thermal transient condition in the biperiodic accelerating structure / D.A. Zavadtsev // Вопросы атомной науки и техники. — 2004. — № 2. — С. 87-89. — Бібліогр.: 4 назв. — англ.
work_keys_str_mv AT zavadtsevda calculationofthermaltransientconditioninthebiperiodicacceleratingstructure
AT zavadtsevda rozrahunokteplovihperehídnihrežimívubíperiodičníipriskorûûčiistrukturí
AT zavadtsevda rasčetteplovyhperehodnyhrežimovvbiperiodičeskoiuskorâûŝeistrukture
first_indexed 2025-12-07T15:35:14Z
last_indexed 2025-12-07T15:35:14Z
_version_ 1850864267253776384