An active charge –exchange q measurements in ITER based upon the diagnostic hydrogen beam
The active charge exchange technique based upon Secondary Charge Exchange effect (SCX) is proposed for safety factor measurements in ITER. The performed numerical modeling shows that measurements of the magnetic pitch angle are possible up to the plasma center with radial resolution of 5 cm and in...
Saved in:
| Published in: | Вопросы атомной науки и техники |
|---|---|
| Date: | 2006 |
| Main Authors: | , |
| Format: | Article |
| Language: | English |
| Published: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2006
|
| Subjects: | |
| Online Access: | https://nasplib.isofts.kiev.ua/handle/123456789/79733 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Cite this: | An active charge –exchange q measurements in ITER based upon the diagnostic hydrogen beam / A.A. Medvedev, V.S. Strelkov // Вопросы атомной науки и техники. — 2006. — № 3. — С. 107-109. — Бібліогр.: 7 назв. — англ. |