High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches
The special calorimeter for measuring total energy of HF-wakefields excited in plasma or dielectric by relativistic electron bunches has been elaborated. Simple by design calorimeter operates in the energy range from 0.02 J up to 780 J. Water is used as an absorbing material. For measuring irradiate...
Saved in:
| Published in: | Вопросы атомной науки и техники |
|---|---|
| Date: | 2005 |
| Main Authors: | , , , |
| Format: | Article |
| Language: | English |
| Published: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2005
|
| Subjects: | |
| Online Access: | https://nasplib.isofts.kiev.ua/handle/123456789/79819 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Cite this: | High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches / V.A. Kiselev, A.F. Linnik, N.I. Onishchenko, V.V. Uskov // Вопросы атомной науки и техники. — 2005. — № 2. — С. 232-234. — Бібліогр.: 10 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| id |
nasplib_isofts_kiev_ua-123456789-79819 |
|---|---|
| record_format |
dspace |
| spelling |
Kiselev, V.A. Linnik, A.F. Onishchenko, N.I. Uskov, V.V. 2015-04-04T20:36:32Z 2015-04-04T20:36:32Z 2005 High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches / V.A. Kiselev, A.F. Linnik, N.I. Onishchenko, V.V. Uskov // Вопросы атомной науки и техники. — 2005. — № 2. — С. 232-234. — Бібліогр.: 10 назв. — англ. 1562-6016 PACS: 41.75.Lx, 41.85.Ja, 41.60.Bq https://nasplib.isofts.kiev.ua/handle/123456789/79819 The special calorimeter for measuring total energy of HF-wakefields excited in plasma or dielectric by relativistic electron bunches has been elaborated. Simple by design calorimeter operates in the energy range from 0.02 J up to 780 J. Water is used as an absorbing material. For measuring irradiated water volume change the capacitive ferroceramic sensor was applied. Sensor sensitivity is 8.7 pF/J that two orders exceeds sensitivity of capacitor-sensor used in our experiments before. The calorimeter is not sensitive to nonuniformity of radiation field, and its response on HFradiation is high enough. Calorimeter design allows along with measuring radiation energy simultaneously controlling the current of bunches sequence. Розроблено спеціальний калориметр для виміру енергії НВЧ–кільватерних полів, збуджуваних в плазмі або діелектрику релятивістськими електронними згустками. Простий по конструкції калориметр працює в діапазоні енергій 0,02-780 Дж. Як поглинаючий матеріал використана вода. Зміна її об’єму вимірюється ємнісним сегнетокерамічним датчиком, чутливість якого складає 8,7 пФ/Дж, що на два порядки перевищує чутливість ємнісних датчиків, які використовувались раніше. Разработан специальный калориметр для измерения полной энергии СВЧ–кильватерных полей, возбуждаемых в плазме или диэлектрике релятивистскими электронными сгустками. Простой по конструкции калориметр работает в диапазоне энергий 0,02-780 Дж. В качестве поглощающего материала использована вода. Для измерения изменения ее объема применен емкостной сегнетокерамический датчик, чувствительность которого составляет 8,7 пФ/Дж, что на два порядка превышает чувствительность применявшихся ранее емкостных датчиков. This work was supported by grants CRDF UP2-2569- KH-04 and DFFD №02.07/325 en Національний науковий центр «Харківський фізико-технічний інститут» НАН України Вопросы атомной науки и техники Plasma diagnostics High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches Калориметр високої чутливості для виміру енергії кільватерних полів, збуджуваних послідовністю електронних згустків Калориметр высокой чувствительности для измерения энергии кильватерных полей, возбуждаемых последовательностью электронных сгустков Article published earlier |
| institution |
Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| collection |
DSpace DC |
| title |
High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches |
| spellingShingle |
High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches Kiselev, V.A. Linnik, A.F. Onishchenko, N.I. Uskov, V.V. Plasma diagnostics |
| title_short |
High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches |
| title_full |
High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches |
| title_fullStr |
High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches |
| title_full_unstemmed |
High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches |
| title_sort |
high sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches |
| author |
Kiselev, V.A. Linnik, A.F. Onishchenko, N.I. Uskov, V.V. |
| author_facet |
Kiselev, V.A. Linnik, A.F. Onishchenko, N.I. Uskov, V.V. |
| topic |
Plasma diagnostics |
| topic_facet |
Plasma diagnostics |
| publishDate |
2005 |
| language |
English |
| container_title |
Вопросы атомной науки и техники |
| publisher |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України |
| format |
Article |
| title_alt |
Калориметр високої чутливості для виміру енергії кільватерних полів, збуджуваних послідовністю електронних згустків Калориметр высокой чувствительности для измерения энергии кильватерных полей, возбуждаемых последовательностью электронных сгустков |
| description |
The special calorimeter for measuring total energy of HF-wakefields excited in plasma or dielectric by relativistic electron bunches has been elaborated. Simple by design calorimeter operates in the energy range from 0.02 J up to 780 J. Water is used as an absorbing material. For measuring irradiated water volume change the capacitive ferroceramic sensor was applied. Sensor sensitivity is 8.7 pF/J that two orders exceeds sensitivity of capacitor-sensor used in our experiments before. The calorimeter is not sensitive to nonuniformity of radiation field, and its response on HFradiation is high enough. Calorimeter design allows along with measuring radiation energy simultaneously controlling the current of bunches sequence.
Розроблено спеціальний калориметр для виміру енергії НВЧ–кільватерних полів, збуджуваних в плазмі або діелектрику релятивістськими електронними згустками. Простий по конструкції калориметр працює в діапазоні енергій 0,02-780 Дж. Як поглинаючий матеріал використана вода. Зміна її об’єму вимірюється ємнісним сегнетокерамічним датчиком, чутливість якого складає 8,7 пФ/Дж, що на два порядки перевищує чутливість ємнісних датчиків, які використовувались раніше.
Разработан специальный калориметр для измерения полной энергии СВЧ–кильватерных полей, возбуждаемых в плазме или диэлектрике релятивистскими электронными сгустками. Простой по конструкции калориметр работает в диапазоне энергий 0,02-780 Дж. В качестве поглощающего материала использована вода. Для измерения изменения ее объема применен емкостной сегнетокерамический датчик, чувствительность которого составляет 8,7 пФ/Дж, что на два порядка превышает чувствительность применявшихся ранее емкостных датчиков.
|
| issn |
1562-6016 |
| url |
https://nasplib.isofts.kiev.ua/handle/123456789/79819 |
| fulltext |
|
| citation_txt |
High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches / V.A. Kiselev, A.F. Linnik, N.I. Onishchenko, V.V. Uskov // Вопросы атомной науки и техники. — 2005. — № 2. — С. 232-234. — Бібліогр.: 10 назв. — англ. |
| work_keys_str_mv |
AT kiselevva highsensitivitycalorimeterformeasuringwakefieldsenergyexcitedbyatrainofelectronbunches AT linnikaf highsensitivitycalorimeterformeasuringwakefieldsenergyexcitedbyatrainofelectronbunches AT onishchenkoni highsensitivitycalorimeterformeasuringwakefieldsenergyexcitedbyatrainofelectronbunches AT uskovvv highsensitivitycalorimeterformeasuringwakefieldsenergyexcitedbyatrainofelectronbunches AT kiselevva kalorimetrvisokoíčutlivostídlâvimíruenergííkílʹvaternihpolívzbudžuvanihposlídovnístûelektronnihzgustkív AT linnikaf kalorimetrvisokoíčutlivostídlâvimíruenergííkílʹvaternihpolívzbudžuvanihposlídovnístûelektronnihzgustkív AT onishchenkoni kalorimetrvisokoíčutlivostídlâvimíruenergííkílʹvaternihpolívzbudžuvanihposlídovnístûelektronnihzgustkív AT uskovvv kalorimetrvisokoíčutlivostídlâvimíruenergííkílʹvaternihpolívzbudžuvanihposlídovnístûelektronnihzgustkív AT kiselevva kalorimetrvysokoičuvstvitelʹnostidlâizmereniâénergiikilʹvaternyhpoleivozbuždaemyhposledovatelʹnostʹûélektronnyhsgustkov AT linnikaf kalorimetrvysokoičuvstvitelʹnostidlâizmereniâénergiikilʹvaternyhpoleivozbuždaemyhposledovatelʹnostʹûélektronnyhsgustkov AT onishchenkoni kalorimetrvysokoičuvstvitelʹnostidlâizmereniâénergiikilʹvaternyhpoleivozbuždaemyhposledovatelʹnostʹûélektronnyhsgustkov AT uskovvv kalorimetrvysokoičuvstvitelʹnostidlâizmereniâénergiikilʹvaternyhpoleivozbuždaemyhposledovatelʹnostʹûélektronnyhsgustkov |
| first_indexed |
2025-11-24T08:19:24Z |
| last_indexed |
2025-11-24T08:19:24Z |
| _version_ |
1850844460985876480 |