High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches

The special calorimeter for measuring total energy of HF-wakefields excited in plasma or dielectric by relativistic electron bunches has been elaborated. Simple by design calorimeter operates in the energy range from 0.02 J up to 780 J. Water is used as an absorbing material. For measuring irradiate...

Full description

Saved in:
Bibliographic Details
Published in:Вопросы атомной науки и техники
Date:2005
Main Authors: Kiselev, V.A., Linnik, A.F., Onishchenko, N.I., Uskov, V.V.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2005
Subjects:
Online Access:https://nasplib.isofts.kiev.ua/handle/123456789/79819
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Cite this:High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches / V.A. Kiselev, A.F. Linnik, N.I. Onishchenko, V.V. Uskov // Вопросы атомной науки и техники. — 2005. — № 2. — С. 232-234. — Бібліогр.: 10 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-79819
record_format dspace
spelling Kiselev, V.A.
Linnik, A.F.
Onishchenko, N.I.
Uskov, V.V.
2015-04-04T20:36:32Z
2015-04-04T20:36:32Z
2005
High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches / V.A. Kiselev, A.F. Linnik, N.I. Onishchenko, V.V. Uskov // Вопросы атомной науки и техники. — 2005. — № 2. — С. 232-234. — Бібліогр.: 10 назв. — англ.
1562-6016
PACS: 41.75.Lx, 41.85.Ja, 41.60.Bq
https://nasplib.isofts.kiev.ua/handle/123456789/79819
The special calorimeter for measuring total energy of HF-wakefields excited in plasma or dielectric by relativistic electron bunches has been elaborated. Simple by design calorimeter operates in the energy range from 0.02 J up to 780 J. Water is used as an absorbing material. For measuring irradiated water volume change the capacitive ferroceramic sensor was applied. Sensor sensitivity is 8.7 pF/J that two orders exceeds sensitivity of capacitor-sensor used in our experiments before. The calorimeter is not sensitive to nonuniformity of radiation field, and its response on HFradiation is high enough. Calorimeter design allows along with measuring radiation energy simultaneously controlling the current of bunches sequence.
Розроблено спеціальний калориметр для виміру енергії НВЧ–кільватерних полів, збуджуваних в плазмі або діелектрику релятивістськими електронними згустками. Простий по конструкції калориметр працює в діапазоні енергій 0,02-780 Дж. Як поглинаючий матеріал використана вода. Зміна її об’єму вимірюється ємнісним сегнетокерамічним датчиком, чутливість якого складає 8,7 пФ/Дж, що на два порядки перевищує чутливість ємнісних датчиків, які використовувались раніше.
Разработан специальный калориметр для измерения полной энергии СВЧ–кильватерных полей, возбуждаемых в плазме или диэлектрике релятивистскими электронными сгустками. Простой по конструкции калориметр работает в диапазоне энергий 0,02-780 Дж. В качестве поглощающего материала использована вода. Для измерения изменения ее объема применен емкостной сегнетокерамический датчик, чувствительность которого составляет 8,7 пФ/Дж, что на два порядка превышает чувствительность применявшихся ранее емкостных датчиков.
This work was supported by grants CRDF UP2-2569- KH-04 and DFFD №02.07/325
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Plasma diagnostics
High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches
Калориметр високої чутливості для виміру енергії кільватерних полів, збуджуваних послідовністю електронних згустків
Калориметр высокой чувствительности для измерения энергии кильватерных полей, возбуждаемых последовательностью электронных сгустков
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches
spellingShingle High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches
Kiselev, V.A.
Linnik, A.F.
Onishchenko, N.I.
Uskov, V.V.
Plasma diagnostics
title_short High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches
title_full High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches
title_fullStr High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches
title_full_unstemmed High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches
title_sort high sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches
author Kiselev, V.A.
Linnik, A.F.
Onishchenko, N.I.
Uskov, V.V.
author_facet Kiselev, V.A.
Linnik, A.F.
Onishchenko, N.I.
Uskov, V.V.
topic Plasma diagnostics
topic_facet Plasma diagnostics
publishDate 2005
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Калориметр високої чутливості для виміру енергії кільватерних полів, збуджуваних послідовністю електронних згустків
Калориметр высокой чувствительности для измерения энергии кильватерных полей, возбуждаемых последовательностью электронных сгустков
description The special calorimeter for measuring total energy of HF-wakefields excited in plasma or dielectric by relativistic electron bunches has been elaborated. Simple by design calorimeter operates in the energy range from 0.02 J up to 780 J. Water is used as an absorbing material. For measuring irradiated water volume change the capacitive ferroceramic sensor was applied. Sensor sensitivity is 8.7 pF/J that two orders exceeds sensitivity of capacitor-sensor used in our experiments before. The calorimeter is not sensitive to nonuniformity of radiation field, and its response on HFradiation is high enough. Calorimeter design allows along with measuring radiation energy simultaneously controlling the current of bunches sequence. Розроблено спеціальний калориметр для виміру енергії НВЧ–кільватерних полів, збуджуваних в плазмі або діелектрику релятивістськими електронними згустками. Простий по конструкції калориметр працює в діапазоні енергій 0,02-780 Дж. Як поглинаючий матеріал використана вода. Зміна її об’єму вимірюється ємнісним сегнетокерамічним датчиком, чутливість якого складає 8,7 пФ/Дж, що на два порядки перевищує чутливість ємнісних датчиків, які використовувались раніше. Разработан специальный калориметр для измерения полной энергии СВЧ–кильватерных полей, возбуждаемых в плазме или диэлектрике релятивистскими электронными сгустками. Простой по конструкции калориметр работает в диапазоне энергий 0,02-780 Дж. В качестве поглощающего материала использована вода. Для измерения изменения ее объема применен емкостной сегнетокерамический датчик, чувствительность которого составляет 8,7 пФ/Дж, что на два порядка превышает чувствительность применявшихся ранее емкостных датчиков.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/79819
fulltext
citation_txt High sensitivity calorimeter for measuring wakefields energy excited by a train of electron bunches / V.A. Kiselev, A.F. Linnik, N.I. Onishchenko, V.V. Uskov // Вопросы атомной науки и техники. — 2005. — № 2. — С. 232-234. — Бібліогр.: 10 назв. — англ.
work_keys_str_mv AT kiselevva highsensitivitycalorimeterformeasuringwakefieldsenergyexcitedbyatrainofelectronbunches
AT linnikaf highsensitivitycalorimeterformeasuringwakefieldsenergyexcitedbyatrainofelectronbunches
AT onishchenkoni highsensitivitycalorimeterformeasuringwakefieldsenergyexcitedbyatrainofelectronbunches
AT uskovvv highsensitivitycalorimeterformeasuringwakefieldsenergyexcitedbyatrainofelectronbunches
AT kiselevva kalorimetrvisokoíčutlivostídlâvimíruenergííkílʹvaternihpolívzbudžuvanihposlídovnístûelektronnihzgustkív
AT linnikaf kalorimetrvisokoíčutlivostídlâvimíruenergííkílʹvaternihpolívzbudžuvanihposlídovnístûelektronnihzgustkív
AT onishchenkoni kalorimetrvisokoíčutlivostídlâvimíruenergííkílʹvaternihpolívzbudžuvanihposlídovnístûelektronnihzgustkív
AT uskovvv kalorimetrvisokoíčutlivostídlâvimíruenergííkílʹvaternihpolívzbudžuvanihposlídovnístûelektronnihzgustkív
AT kiselevva kalorimetrvysokoičuvstvitelʹnostidlâizmereniâénergiikilʹvaternyhpoleivozbuždaemyhposledovatelʹnostʹûélektronnyhsgustkov
AT linnikaf kalorimetrvysokoičuvstvitelʹnostidlâizmereniâénergiikilʹvaternyhpoleivozbuždaemyhposledovatelʹnostʹûélektronnyhsgustkov
AT onishchenkoni kalorimetrvysokoičuvstvitelʹnostidlâizmereniâénergiikilʹvaternyhpoleivozbuždaemyhposledovatelʹnostʹûélektronnyhsgustkov
AT uskovvv kalorimetrvysokoičuvstvitelʹnostidlâizmereniâénergiikilʹvaternyhpoleivozbuždaemyhposledovatelʹnostʹûélektronnyhsgustkov
first_indexed 2025-11-24T08:19:24Z
last_indexed 2025-11-24T08:19:24Z
_version_ 1850844460985876480