A РС-controlled beam scanning system at the technological electron LINAC
The regulatory documents for a number of technological processes (sterilization and others) require that a continuous control and archiving of beam scanning regime should be provided. To meet these conditions at the radiation-technological facility with the electron linear accelerator LU-10 (10 Me...
Gespeichert in:
| Datum: | 2006 |
|---|---|
| Hauptverfasser: | , , , , , |
| Format: | Artikel |
| Sprache: | English |
| Veröffentlicht: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2006
|
| Schriftenreihe: | Вопросы атомной науки и техники |
| Schlagworte: | |
| Online Zugang: | https://nasplib.isofts.kiev.ua/handle/123456789/79888 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Zitieren: | A РС-controlled beam scanning system at the technological electron LINAC / S.P. Karasyov, R.I. Pomatsalyuk, A.Eh. Tenishev, V.L. Uvarov, V.A. Shevchenko, I.N. Shlyakhov // Вопросы атомной науки и техники. — 2006. — № 3. — С. 191-193. — Бібліогр.: 3 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| Zusammenfassung: | The regulatory documents for a number of technological processes (sterilization and others) require that a continuous
control and archiving of beam scanning regime should be provided. To meet these conditions at the radiation-technological
facility with the electron linear accelerator LU-10 (10 MeV, 10 kW), an automated complex of
scanner control was designed and put into operation. The complex is a CAMAC-based autonomous system controlled
by a computer. It provides a programmed control of the beam scanning zone width proceeding from the assigned
dimensions of the object under treatment, within 20 to 60 cm, with an automatic setting of the center of the
zone in the middle of the object. The complex control also includes the possibility of correcting the position of the
beam-scanning center in order to compensate the angle of beam entrance into the scanner electromagnet. |
|---|