Detectors for selective registration of charged particles and gamma-quanta
A new design is proposed and described of a combined detector (CD) for simultaneous detection of charged particles and gamma-quanta. The CD comprises a single crystalline plate of ZnSe(Te) placed onto the output window of a scintillating transparent light transducer made of CsI(Tl) and Al₂O₃(Ti) in...
Saved in:
| Published in: | Вопросы атомной науки и техники |
|---|---|
| Date: | 2002 |
| Main Authors: | Ryzhikov, V., Starzhinskiy, N., Katrunov, K., Gal’chinetskiy, L., Chernikov, V., Zelenskaya, O., Krivonosov, E., Litvinov, L., Galkin, S., Loseva, E. |
| Format: | Article |
| Language: | English |
| Published: |
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
2002
|
| Subjects: | |
| Online Access: | https://nasplib.isofts.kiev.ua/handle/123456789/80097 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Cite this: | Detectors for selective registration of charged particles and gamma-quanta / V. Ryzhikov, N. Starzhinskiy, K. Katrunov, L. Gal’chinetskiy, V. Chernikov, O. Zelenskaya, E. Krivonosov, L. Litvinov, S. Galkin, E. Loseva // Вопросы атомной науки и техники. — 2002. — № 3. — С. 130-132. — Бібліогр.: 6 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of UkraineSimilar Items
Detectors of charged particles and low-energy gamma-quanta on the basis of Ticor single crystals
by: Litvinov, L.A., et al.
Published: (2004)
by: Litvinov, L.A., et al.
Published: (2004)
Registration of the thermal neutrons using uncooled Si planar detector
by: Bochek, G.L., et al.
Published: (2016)
by: Bochek, G.L., et al.
Published: (2016)
Применение полупроводниковых детекторов для учета и контроля РАО
by: Давыдов, Л.Н., et al.
Published: (2002)
by: Давыдов, Л.Н., et al.
Published: (2002)
Transmission of gamma-quanta through vibrating target
by: Ya. Dzyublik
Published: (2015)
by: Ya. Dzyublik
Published: (2015)
Combined detectors of charged particles based on zinc selenide scintillators and silicon photodiodes
by: Ryzhikov, V.D., et al.
Published: (2001)
by: Ryzhikov, V.D., et al.
Published: (2001)
Sensitivity studies of beta-radiation detector based on small-crystalline scintillator ZnSe(Te)
by: Gavrylyuk, V., et al.
Published: (2001)
by: Gavrylyuk, V., et al.
Published: (2001)
Detectors based on Cd(Zn)Te semiconductors for x-ray and gamma radiation registration
by: S. M. Levytskyi
Published: (2020)
by: S. M. Levytskyi
Published: (2020)
Spectrometric registration of x-ray and gamma radiation by detecting modules “silicon planar detector - scintillator”
by: Bochek, G.L., et al.
Published: (2022)
by: Bochek, G.L., et al.
Published: (2022)
CdZnTe- and TlBr-detectors response simulation for registration of the mixed beta- and gamma-radiation
by: A. I. Skrypnik
Published: (2015)
by: A. I. Skrypnik
Published: (2015)
Радиационная повреждаемость нанокристаллических CrN-покрытий
by: Василенко, Р.Л., et al.
Published: (2005)
by: Василенко, Р.Л., et al.
Published: (2005)
Механические и оптические свойства хрома, деформированного в области температур 77…300 К
by: Метолиди, Э.Н., et al.
Published: (2005)
by: Метолиди, Э.Н., et al.
Published: (2005)
Исследовательский комплекс для изучения процессов диффузии в металлах и сплавах радиоактивным методом
by: Азаренков, Н.А., et al.
Published: (2005)
by: Азаренков, Н.А., et al.
Published: (2005)
ИК-метод диагностики электрического заряда в облучаемом диэлектрике
by: Базалеев, Н.И., et al.
Published: (2005)
by: Базалеев, Н.И., et al.
Published: (2005)
Alpha-, beta-, gamma-radiometric measurements using semiconductor detectors
by: Grigoryev, A.N., et al.
Published: (2014)
by: Grigoryev, A.N., et al.
Published: (2014)
Radiation-induced pocesses in A²B⁶ oxide compounds under proton and gamma-irradiation
by: Starzhinskiy, N.G., et al.
Published: (2005)
by: Starzhinskiy, N.G., et al.
Published: (2005)
Optimization of technology for fabrication of sectional nuclear radiation detectors based on high-resistance silicon
by: Gaidar, G.P., et al.
Published: (2017)
by: Gaidar, G.P., et al.
Published: (2017)
Method for energy scale calibration of the scintillation detector at registration of recoil protons
by: Bozhko, V.P., et al.
Published: (2009)
by: Bozhko, V.P., et al.
Published: (2009)
Simulation of characteristics of gamma-radiation detectors based on mercury compounds
by: Skrypnyk, A.I., et al.
Published: (2013)
by: Skrypnyk, A.I., et al.
Published: (2013)
Gamma flaw-detectors for radiographic and radiometric testing of quality of industrial products
by: V. N. Khoroshev, et al.
Published: (2011)
by: V. N. Khoroshev, et al.
Published: (2011)
Large area detector of low-energy gamma radiation
by: Nepokupnaya, T.A., et al.
Published: (2017)
by: Nepokupnaya, T.A., et al.
Published: (2017)
Detectors for Registration of Electron Radiation Fluxes in Near- Earth Space
by: Bazaleev, M. I., et al.
Published: (2012)
by: Bazaleev, M. I., et al.
Published: (2012)
Review of Characteristics of Electric Coolers for HPGe Gamma Radiation Detectors
by: A. D. Sokolov, et al.
Published: (2015)
by: A. D. Sokolov, et al.
Published: (2015)
Schottky structures nZnSe(O,Te)/Ni as candidates for selective ultraviolet detectors
by: Katrunov, K., et al.
Published: (2008)
by: Katrunov, K., et al.
Published: (2008)
Эффективные сцинтилляционные материалы на основе твердых растворов ZnS1–xTex и перспективы их применения
by: Katrunov, K. A., et al.
Published: (2011)
by: Katrunov, K. A., et al.
Published: (2011)
Thin-film termoacoustic detector for a registration of microwave pulses of nanosecond duration
by: Andreev, V., et al.
Published: (2004)
by: Andreev, V., et al.
Published: (2004)
Theory of radiation and absorption of deformed field quanta
by: Vakarchuk, I.O.
Published: (2008)
by: Vakarchuk, I.O.
Published: (2008)
Optimal choice of semiconductor gamma detector for determining radionuclide content genesis of Chornobyl
by: A. K. Kalinovskij
Published: (2014)
by: A. K. Kalinovskij
Published: (2014)
Computation of response function of multi-detector device for gamma radiation angular distribution measuring
by: Batiy, V.G., et al.
Published: (2004)
by: Batiy, V.G., et al.
Published: (2004)
Excitation cross cection of the 11/2– isomeric state of 137Ce nucleus in (γ, n) reaction in the 11–18-MeV energy interval of gamma quanta
by: V. M. Mazur, et al.
Published: (2016)
by: V. M. Mazur, et al.
Published: (2016)
Excitation Cross Section of the 11/2– Isomeric State of 137Ce Nucleus in (γ, n) Reaction in the 11–18-MeV Energy Interval of Gamma Quanta
by: V. M. Mazur, et al.
Published: (2016)
by: V. M. Mazur, et al.
Published: (2016)
On radiation-induced optical and luminescence phenomena in thermally pretreated GSO:Ce crystals
by: Nagornaya, L., et al.
Published: (2005)
by: Nagornaya, L., et al.
Published: (2005)
On the optimum geometric shapes of ZnSe-based scintillation elements
by: Katrunov, K., et al.
Published: (2004)
by: Katrunov, K., et al.
Published: (2004)
Особенности диагностики функционального состояния одноклеточных водорослей в жидких средах люминесцентными методами
by: Вакуленко, О.В., et al.
Published: (2013)
by: Вакуленко, О.В., et al.
Published: (2013)
Методы анализа реакции организма человека на изменения солнечной и геомагнитной активности
by: Грабко, Н.В., et al.
Published: (2008)
by: Грабко, Н.В., et al.
Published: (2008)
Метод прижизненной морфометрии ядерных эритроцитов рыб
by: Андреева, А.Ю., et al.
Published: (2012)
by: Андреева, А.Ю., et al.
Published: (2012)
Количественные показатели зоопланктона Куршского залива при разных способах отбора проб
by: Семенова, А.С.
Published: (2011)
by: Семенова, А.С.
Published: (2011)
Инфузории Stylonichia mytilus как объект для автоматизированного экспресс-анализа энтеротоксинов Escherichia coli
by: Сухарев, Ю.С.
Published: (2013)
by: Сухарев, Ю.С.
Published: (2013)
Методические особенности пробоподготовки взвешенных веществ и донных отложений
by: Жежеря, В.А., et al.
Published: (2015)
by: Жежеря, В.А., et al.
Published: (2015)
Influence of the quantum dots bandgap and their dispersion on the loss of luminescent quanta
by: M. R. Kulish, et al.
Published: (2020)
by: M. R. Kulish, et al.
Published: (2020)
Influence of the quantum dots' bandgap and their dispersion on the loss of luminescent quanta
by: Kulish, M.R., et al.
Published: (2020)
by: Kulish, M.R., et al.
Published: (2020)
Similar Items
-
Detectors of charged particles and low-energy gamma-quanta on the basis of Ticor single crystals
by: Litvinov, L.A., et al.
Published: (2004) -
Registration of the thermal neutrons using uncooled Si planar detector
by: Bochek, G.L., et al.
Published: (2016) -
Применение полупроводниковых детекторов для учета и контроля РАО
by: Давыдов, Л.Н., et al.
Published: (2002) -
Transmission of gamma-quanta through vibrating target
by: Ya. Dzyublik
Published: (2015) -
Combined detectors of charged particles based on zinc selenide scintillators and silicon photodiodes
by: Ryzhikov, V.D., et al.
Published: (2001)