Use of electrostatic gridded lenses in the laser ion source at CERN

The GEL LEBT provides high efficiency beam transport and matching to the RFQ acceptance in the 4-dimensional phase space. The rms emittance growth is relatively small even for 60 kV extraction voltage. The number of particles occupying the 4-D RFQ acceptance strongly depends from the beam emittance...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Вопросы атомной науки и техники
Datum:1999
Hauptverfasser: Derbilov, V.I., Ostroumov, P.N., Kugler, H., Lisi, N., Meyer, C., Scrivens, R.
Format: Artikel
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 1999
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/81149
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Use of electrostatic gridded lenses in the laser ion source at CERN / V. Derbilov, P. Ostroumov, H. Kugler, N. Lisi, C. Meyer, R. Scrivens // Вопросы атомной науки и техники. — 1999. — № 3. — С. 33-35. — Бібліогр.: 4 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-81149
record_format dspace
spelling Derbilov, V.I.
Ostroumov, P.N.
Kugler, H.
Lisi, N.
Meyer, C.
Scrivens, R.
2015-05-11T18:24:24Z
2015-05-11T18:24:24Z
1999
Use of electrostatic gridded lenses in the laser ion source at CERN / V. Derbilov, P. Ostroumov, H. Kugler, N. Lisi, C. Meyer, R. Scrivens // Вопросы атомной науки и техники. — 1999. — № 3. — С. 33-35. — Бібліогр.: 4 назв. — англ.
1562-6016
https://nasplib.isofts.kiev.ua/handle/123456789/81149
The GEL LEBT provides high efficiency beam transport and matching to the RFQ acceptance in the 4-dimensional phase space. The rms emittance growth is relatively small even for 60 kV extraction voltage. The number of particles occupying the 4-D RFQ acceptance strongly depends from the beam emittance at the entrance of the GEL LEBT. In most realistic case with the input emittance equal to the measured one, which is 320 p×mm×mrad (4×rms emittance) the number of particles inside the 4-D space with the projection emittance of 200 p×mm×mrad is 38% at the entrance and 35% at the output of GEL LEBT, which means that LEBT does not practically destroy beam emittance. The experimental value of the yield to the double aperture is 35% and confirms the expected performance of the GEL LEBT.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Use of electrostatic gridded lenses in the laser ion source at CERN
Использование электростатических сеточных линз в ионном источнике церн
Article
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Use of electrostatic gridded lenses in the laser ion source at CERN
spellingShingle Use of electrostatic gridded lenses in the laser ion source at CERN
Derbilov, V.I.
Ostroumov, P.N.
Kugler, H.
Lisi, N.
Meyer, C.
Scrivens, R.
title_short Use of electrostatic gridded lenses in the laser ion source at CERN
title_full Use of electrostatic gridded lenses in the laser ion source at CERN
title_fullStr Use of electrostatic gridded lenses in the laser ion source at CERN
title_full_unstemmed Use of electrostatic gridded lenses in the laser ion source at CERN
title_sort use of electrostatic gridded lenses in the laser ion source at cern
author Derbilov, V.I.
Ostroumov, P.N.
Kugler, H.
Lisi, N.
Meyer, C.
Scrivens, R.
author_facet Derbilov, V.I.
Ostroumov, P.N.
Kugler, H.
Lisi, N.
Meyer, C.
Scrivens, R.
publishDate 1999
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
format Article
title_alt Использование электростатических сеточных линз в ионном источнике церн
description The GEL LEBT provides high efficiency beam transport and matching to the RFQ acceptance in the 4-dimensional phase space. The rms emittance growth is relatively small even for 60 kV extraction voltage. The number of particles occupying the 4-D RFQ acceptance strongly depends from the beam emittance at the entrance of the GEL LEBT. In most realistic case with the input emittance equal to the measured one, which is 320 p×mm×mrad (4×rms emittance) the number of particles inside the 4-D space with the projection emittance of 200 p×mm×mrad is 38% at the entrance and 35% at the output of GEL LEBT, which means that LEBT does not practically destroy beam emittance. The experimental value of the yield to the double aperture is 35% and confirms the expected performance of the GEL LEBT.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/81149
citation_txt Use of electrostatic gridded lenses in the laser ion source at CERN / V. Derbilov, P. Ostroumov, H. Kugler, N. Lisi, C. Meyer, R. Scrivens // Вопросы атомной науки и техники. — 1999. — № 3. — С. 33-35. — Бібліогр.: 4 назв. — англ.
work_keys_str_mv AT derbilovvi useofelectrostaticgriddedlensesinthelaserionsourceatcern
AT ostroumovpn useofelectrostaticgriddedlensesinthelaserionsourceatcern
AT kuglerh useofelectrostaticgriddedlensesinthelaserionsourceatcern
AT lisin useofelectrostaticgriddedlensesinthelaserionsourceatcern
AT meyerc useofelectrostaticgriddedlensesinthelaserionsourceatcern
AT scrivensr useofelectrostaticgriddedlensesinthelaserionsourceatcern
AT derbilovvi ispolʹzovanieélektrostatičeskihsetočnyhlinzvionnomistočnikecern
AT ostroumovpn ispolʹzovanieélektrostatičeskihsetočnyhlinzvionnomistočnikecern
AT kuglerh ispolʹzovanieélektrostatičeskihsetočnyhlinzvionnomistočnikecern
AT lisin ispolʹzovanieélektrostatičeskihsetočnyhlinzvionnomistočnikecern
AT meyerc ispolʹzovanieélektrostatičeskihsetočnyhlinzvionnomistočnikecern
AT scrivensr ispolʹzovanieélektrostatičeskihsetočnyhlinzvionnomistočnikecern
first_indexed 2025-12-07T15:38:21Z
last_indexed 2025-12-07T15:38:21Z
_version_ 1850864463043887105