Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions

In this article (first part of one) we investigated efficiency dependence of gyro-BWO on oscillation frequencies f=7.7…10 GHz under fixed injection energy of an electron beam γ0=2. We obtained efficiency increasing of gyro-BWO from ~10 up to ~30% at above mentioned oscillation frequency band f=7.7…1...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Вопросы атомной науки и техники
Datum:2015
1. Verfasser: Khoruzhiy, V.
Sprache:English
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2015
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/82233
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions / V. Khoruzhiy // Вопросы атомной науки и техники. — 2015. — № 1. — С.134-136. — Бібліогр.: 4 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-82233
record_format dspace
spelling Khoruzhiy, V.
2015-05-27T04:47:56Z
2015-05-27T04:47:56Z
2015
Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions / V. Khoruzhiy // Вопросы атомной науки и техники. — 2015. — № 1. — С.134-136. — Бібліогр.: 4 назв. — англ.
1562-6016
PACS: 84.30.Ng
https://nasplib.isofts.kiev.ua/handle/123456789/82233
In this article (first part of one) we investigated efficiency dependence of gyro-BWO on oscillation frequencies f=7.7…10 GHz under fixed injection energy of an electron beam γ0=2. We obtained efficiency increasing of gyro-BWO from ~10 up to ~30% at above mentioned oscillation frequency band f=7.7…10 GHz. Then (second part) we investigated efficiency dependence on longitudinal and transversal waveguide dimensions under the same oscillation frequencies and fixed energy injection of an electron beam. High efficiency η~ 0.3 still remains the same under fixed distance between radii of coaxial waveguide. High efficiency η takes place too under varying length L of space interaction 60сm ≥ L ≥ 30 сm due to form changing like-a-bell guiding magnetic field.
Исследовали (первая часть статьи) зависимость КПД гиро-ЛОВ от частоты колебаний в диапазоне F = 7.7…10 ГГц при фиксированной энергии инжекции пучка электронов γ0 = 2. Получили увеличение КПД гиро-ЛОВ от ~ 10 до ~ 30% для неоднородного распределения ведущего магнитного поля. Исследовали (вторая часть статьи) зависимость КПД от продольных и поперечных размеров волновода в том же диапазоне частот и при фиксированной энергии инжекции электронного пучка. Высокое значение КПД (~ 0,3) не меняется при таком изменении поперечных размеров волновода, при котором расстояние между радиусами коаксиального волновода остается неизменным. Высокое значение КПД имеет место при изменении длины пространства взаимодействия 60 см ≥ L ≥ 30 см в случае соответствующего изменения формы и амплитуды ведущего магнитного поля.
Досліджували (перша частина статті) залежність ККД гіро-ЛЗХ від частоти коливань у діапазоні F = (7.7…10) ГГц при фіксованій енергії інжекції пучка електронів γ0=2. Отримали збільшення ККД гіро-ЛЗХ від ~ 10 до ~ 30% для неоднорідного розподілу ведучого магнітного поля. Досліджували (друга частина статті) залежність ККД від поздовжніх і поперечних розмірів хвилеводу в тому ж діапазоні частот і при фіксованій енергії інжекції електронного пучка. Високе значення ККД (~ 0,3) не змінюється при такій зміні поперечних розмірів хвилеводу, при якому відстань між радіусами коаксіального хвилеводу залишається незмінною між радіусами коаксіального хвилеводу. Високе значення ККД має місце при зміні довжини простору взаємодії 60 см ≥ L ≥ 30 см у разі відповідної зміни форми і амплітуди ведучого магнітного поля.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Плазменная электроника
Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions
Компьютерное исследование КПД коаксиальной гиро-ЛОВ от частоты колебаний и продольных размеров волновода
Комп'ютерне дослідження ККД коаксіальної гіро-ЛЗХ від частоти коливань і поздовжніх розмірів хвилеводу
published earlier
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
title Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions
spellingShingle Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions
Khoruzhiy, V.
Плазменная электроника
title_short Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions
title_full Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions
title_fullStr Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions
title_full_unstemmed Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions
title_sort computer investigation of coaxial gyro-bwo efficiency depending on oscillation frequency and longitudinal waveguide dimensions
author Khoruzhiy, V.
author_facet Khoruzhiy, V.
topic Плазменная электроника
topic_facet Плазменная электроника
publishDate 2015
language English
container_title Вопросы атомной науки и техники
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
title_alt Компьютерное исследование КПД коаксиальной гиро-ЛОВ от частоты колебаний и продольных размеров волновода
Комп'ютерне дослідження ККД коаксіальної гіро-ЛЗХ від частоти коливань і поздовжніх розмірів хвилеводу
description In this article (first part of one) we investigated efficiency dependence of gyro-BWO on oscillation frequencies f=7.7…10 GHz under fixed injection energy of an electron beam γ0=2. We obtained efficiency increasing of gyro-BWO from ~10 up to ~30% at above mentioned oscillation frequency band f=7.7…10 GHz. Then (second part) we investigated efficiency dependence on longitudinal and transversal waveguide dimensions under the same oscillation frequencies and fixed energy injection of an electron beam. High efficiency η~ 0.3 still remains the same under fixed distance between radii of coaxial waveguide. High efficiency η takes place too under varying length L of space interaction 60сm ≥ L ≥ 30 сm due to form changing like-a-bell guiding magnetic field. Исследовали (первая часть статьи) зависимость КПД гиро-ЛОВ от частоты колебаний в диапазоне F = 7.7…10 ГГц при фиксированной энергии инжекции пучка электронов γ0 = 2. Получили увеличение КПД гиро-ЛОВ от ~ 10 до ~ 30% для неоднородного распределения ведущего магнитного поля. Исследовали (вторая часть статьи) зависимость КПД от продольных и поперечных размеров волновода в том же диапазоне частот и при фиксированной энергии инжекции электронного пучка. Высокое значение КПД (~ 0,3) не меняется при таком изменении поперечных размеров волновода, при котором расстояние между радиусами коаксиального волновода остается неизменным. Высокое значение КПД имеет место при изменении длины пространства взаимодействия 60 см ≥ L ≥ 30 см в случае соответствующего изменения формы и амплитуды ведущего магнитного поля. Досліджували (перша частина статті) залежність ККД гіро-ЛЗХ від частоти коливань у діапазоні F = (7.7…10) ГГц при фіксованій енергії інжекції пучка електронів γ0=2. Отримали збільшення ККД гіро-ЛЗХ від ~ 10 до ~ 30% для неоднорідного розподілу ведучого магнітного поля. Досліджували (друга частина статті) залежність ККД від поздовжніх і поперечних розмірів хвилеводу в тому ж діапазоні частот і при фіксованій енергії інжекції електронного пучка. Високе значення ККД (~ 0,3) не змінюється при такій зміні поперечних розмірів хвилеводу, при якому відстань між радіусами коаксіального хвилеводу залишається незмінною між радіусами коаксіального хвилеводу. Високе значення ККД має місце при зміні довжини простору взаємодії 60 см ≥ L ≥ 30 см у разі відповідної зміни форми і амплітуди ведучого магнітного поля.
issn 1562-6016
url https://nasplib.isofts.kiev.ua/handle/123456789/82233
citation_txt Computer investigation of coaxial gyro-BWO efficiency depending on oscillation frequency and longitudinal waveguide dimensions / V. Khoruzhiy // Вопросы атомной науки и техники. — 2015. — № 1. — С.134-136. — Бібліогр.: 4 назв. — англ.
work_keys_str_mv AT khoruzhiyv computerinvestigationofcoaxialgyrobwoefficiencydependingonoscillationfrequencyandlongitudinalwaveguidedimensions
AT khoruzhiyv kompʹûternoeissledovaniekpdkoaksialʹnoigirolovotčastotykolebaniiiprodolʹnyhrazmerovvolnovoda
AT khoruzhiyv kompûternedoslídžennâkkdkoaksíalʹnoígírolzhvídčastotikolivanʹípozdovžníhrozmírívhvilevodu
first_indexed 2025-12-07T21:01:20Z
last_indexed 2025-12-07T21:01:20Z
_version_ 1850884783215738880