Image quality as a possible method of in situ monitoring the in-vessel mirrors
The plasma facing mirrors (FM) in ITER will be subjected to sputtering and / or contamination with the rates
 depending on mirror locations. The result of influence of both these factors will be reduce of mirror reflectance (R) and
 worsen the quality of transmitted image (IQ). This...
Gespeichert in:
| Veröffentlicht in: | Вопросы атомной науки и техники |
|---|---|
| Datum: | 2006 |
| Hauptverfasser: | , , , , , , , , , , |
| Format: | Artikel |
| Sprache: | Englisch |
| Veröffentlicht: |
2006
|
| Schlagworte: | |
| Online Zugang: | https://nasplib.isofts.kiev.ua/handle/123456789/82354 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| Zitieren: | Image quality as a possible method of in situ monitoring the in-vessel mirrors / V.G. Konovalov, M.N. Makhov, A.N. Shapoval, N. Ashikawa, S. Masuzaki, A. Sagara, D.I. Naidenkova, I.V. Ryzhkov, A.F. Shtan’, S.I. Solodovchenko, V.S. Voitsenya // Вопросы атомной науки и техники. — 2006. — № 6. — С. 244-246. — Бібліогр.: 3 назв. — англ. |
Institution
Digital Library of Periodicals of National Academy of Sciences of Ukraine| _version_ | 1862645282779430912 |
|---|---|
| author | Konovalov, V.G. Makhov, M.N. Shapoval, A.N. Ashikawa, N. Masuzaki, S. Sagara, A. Naidenkova, D.I. Ryzhkov, I.V. Shtan, A.F. Solodovchenko, S.I. Voitsenya, V.S. |
| author_facet | Konovalov, V.G. Makhov, M.N. Shapoval, A.N. Ashikawa, N. Masuzaki, S. Sagara, A. Naidenkova, D.I. Ryzhkov, I.V. Shtan, A.F. Solodovchenko, S.I. Voitsenya, V.S. |
| citation_txt | Image quality as a possible method of in situ monitoring the in-vessel mirrors / V.G. Konovalov, M.N. Makhov, A.N. Shapoval, N. Ashikawa, S. Masuzaki, A. Sagara, D.I. Naidenkova, I.V. Ryzhkov, A.F. Shtan’, S.I. Solodovchenko, V.S. Voitsenya // Вопросы атомной науки и техники. — 2006. — № 6. — С. 244-246. — Бібліогр.: 3 назв. — англ. |
| collection | DSpace DC |
| container_title | Вопросы атомной науки и техники |
| description | The plasma facing mirrors (FM) in ITER will be subjected to sputtering and / or contamination with the rates
depending on mirror locations. The result of influence of both these factors will be reduce of mirror reflectance (R) and
worsen the quality of transmitted image (IQ). This implies that control of the mirror quality in- situ is an actual
problem, and this work is an attempt to approach to its solution. The method suggested for evaluation of IQ was applied
to mirrors exposed in LHD, TRIAM-1M, TS and in the DSM-2 stand (IPP NSC KIPT).
|
| first_indexed | 2025-12-01T10:35:25Z |
| format | Article |
| fulltext | |
| id | nasplib_isofts_kiev_ua-123456789-82354 |
| institution | Digital Library of Periodicals of National Academy of Sciences of Ukraine |
| language | English |
| last_indexed | 2025-12-01T10:35:25Z |
| publishDate | 2006 |
| record_format | dspace |
| spelling | Konovalov, V.G. Makhov, M.N. Shapoval, A.N. Ashikawa, N. Masuzaki, S. Sagara, A. Naidenkova, D.I. Ryzhkov, I.V. Shtan, A.F. Solodovchenko, S.I. Voitsenya, V.S. 2015-05-28T19:04:04Z 2015-05-28T19:04:04Z 2006 Image quality as a possible method of in situ monitoring the in-vessel mirrors / V.G. Konovalov, M.N. Makhov, A.N. Shapoval, N. Ashikawa, S. Masuzaki, A. Sagara, D.I. Naidenkova, I.V. Ryzhkov, A.F. Shtan’, S.I. Solodovchenko, V.S. Voitsenya // Вопросы атомной науки и техники. — 2006. — № 6. — С. 244-246. — Бібліогр.: 3 назв. — англ. PACS: 52.40.Hf ; 78.68.+m; 79.20.Rf https://nasplib.isofts.kiev.ua/handle/123456789/82354 The plasma facing mirrors (FM) in ITER will be subjected to sputtering and / or contamination with the rates
 depending on mirror locations. The result of influence of both these factors will be reduce of mirror reflectance (R) and
 worsen the quality of transmitted image (IQ). This implies that control of the mirror quality in- situ is an actual
 problem, and this work is an attempt to approach to its solution. The method suggested for evaluation of IQ was applied
 to mirrors exposed in LHD, TRIAM-1M, TS and in the DSM-2 stand (IPP NSC KIPT). en Вопросы атомной науки и техники Plasma diagnostics Image quality as a possible method of in situ monitoring the in-vessel mirrors Article published earlier |
| spellingShingle | Image quality as a possible method of in situ monitoring the in-vessel mirrors Konovalov, V.G. Makhov, M.N. Shapoval, A.N. Ashikawa, N. Masuzaki, S. Sagara, A. Naidenkova, D.I. Ryzhkov, I.V. Shtan, A.F. Solodovchenko, S.I. Voitsenya, V.S. Plasma diagnostics |
| title | Image quality as a possible method of in situ monitoring the in-vessel mirrors |
| title_full | Image quality as a possible method of in situ monitoring the in-vessel mirrors |
| title_fullStr | Image quality as a possible method of in situ monitoring the in-vessel mirrors |
| title_full_unstemmed | Image quality as a possible method of in situ monitoring the in-vessel mirrors |
| title_short | Image quality as a possible method of in situ monitoring the in-vessel mirrors |
| title_sort | image quality as a possible method of in situ monitoring the in-vessel mirrors |
| topic | Plasma diagnostics |
| topic_facet | Plasma diagnostics |
| url | https://nasplib.isofts.kiev.ua/handle/123456789/82354 |
| work_keys_str_mv | AT konovalovvg imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors AT makhovmn imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors AT shapovalan imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors AT ashikawan imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors AT masuzakis imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors AT sagaraa imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors AT naidenkovadi imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors AT ryzhkoviv imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors AT shtanaf imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors AT solodovchenkosi imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors AT voitsenyavs imagequalityasapossiblemethodofinsitumonitoringtheinvesselmirrors |