Magnetic diagnostics for torsatron U-2M

The features of application of magnetic diagnostics in torsatron U-2M are described. The methods to account for the
 influence of the metal environment and induced magnetic fields on the results of magnetic measurements are presented.
 During the experimental program on torsatron U-2...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Вопросы атомной науки и техники
Datum:2011
Hauptverfasser: Pashnev, V.K., Petrushenya, A.A., Sorokovoy, E.L., Krasnyj, V.V.
Format: Artikel
Sprache:Englisch
Veröffentlicht: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2011
Schlagworte:
Online Zugang:https://nasplib.isofts.kiev.ua/handle/123456789/91069
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Zitieren:Magnetic diagnostics for torsatron U-2M / V.K. Pashnev, A.A. Petrushenya, E.L. Sorokovoy, V.V. Krasnyj // Вопросы атомной науки и техники. — 2011. — № 1. — С. 176-178. — Бібліогр.: 6 назв. — англ.

Institution

Digital Library of Periodicals of National Academy of Sciences of Ukraine
_version_ 1862698788973445120
author Pashnev, V.K.
Petrushenya, A.A.
Sorokovoy, E.L.
Krasnyj, V.V.
author_facet Pashnev, V.K.
Petrushenya, A.A.
Sorokovoy, E.L.
Krasnyj, V.V.
citation_txt Magnetic diagnostics for torsatron U-2M / V.K. Pashnev, A.A. Petrushenya, E.L. Sorokovoy, V.V. Krasnyj // Вопросы атомной науки и техники. — 2011. — № 1. — С. 176-178. — Бібліогр.: 6 назв. — англ.
collection DSpace DC
container_title Вопросы атомной науки и техники
description The features of application of magnetic diagnostics in torsatron U-2M are described. The methods to account for the
 influence of the metal environment and induced magnetic fields on the results of magnetic measurements are presented.
 During the experimental program on torsatron U-2M with help of magnetic diagnostics, the most important
 characteristics of the plasma, such as the value of the plasma energy content, the energy confinement time, the power
 inputted in the plasma, the value of Pfirsch-Schluter currents, the presence of magnetic islands, the shift of magnetic
 surfaces, the structure of MHD instabilities will be determined Описано особливості застосування магнітної діагностики в торсатроні U-2M. Представлено методи врахування впливу металевого оточення на результатах магнітних вимірювань. У ході експериментальної програми на торсатроні U-2M за допомогою магнітної діагностики визначатимуться найбільш важливі характеристики плазми, такі, як величина енерговмісту плазми, енергетичний час життя, введена в плазму потужність, величина струмів Пфірша-Шлюттера, наявність магнітних островів, зсув магнітних поверхонь, структура МГД-нестійкостей. Описаны особенности применения магнитной диагностики в торсатроне U-2M. Представлены методы учета влияния металлического окружения на результаты магнитных измерений. В ходе экспериментальной программы на торсатроне U-2M с помощью магнитной диагностики будут определяться наиболее важные характеристики плазмы, такие, как величина энергосодержания плазмы, энергетическое время жизни, введенная в плазму мощность, величина токов Пфирша-Шлюттера, наличие магнитных островов, смещение магнитных поверхностей, структура МГД-неустойчивостей.
first_indexed 2025-12-07T16:33:54Z
format Article
fulltext
id nasplib_isofts_kiev_ua-123456789-91069
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
issn 1562-6016
language English
last_indexed 2025-12-07T16:33:54Z
publishDate 2011
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
record_format dspace
spelling Pashnev, V.K.
Petrushenya, A.A.
Sorokovoy, E.L.
Krasnyj, V.V.
2016-01-06T16:17:08Z
2016-01-06T16:17:08Z
2011
Magnetic diagnostics for torsatron U-2M / V.K. Pashnev, A.A. Petrushenya, E.L. Sorokovoy, V.V. Krasnyj // Вопросы атомной науки и техники. — 2011. — № 1. — С. 176-178. — Бібліогр.: 6 назв. — англ.
1562-6016
PACS: 52.55.Dy, 52.55.Hc
https://nasplib.isofts.kiev.ua/handle/123456789/91069
The features of application of magnetic diagnostics in torsatron U-2M are described. The methods to account for the
 influence of the metal environment and induced magnetic fields on the results of magnetic measurements are presented.
 During the experimental program on torsatron U-2M with help of magnetic diagnostics, the most important
 characteristics of the plasma, such as the value of the plasma energy content, the energy confinement time, the power
 inputted in the plasma, the value of Pfirsch-Schluter currents, the presence of magnetic islands, the shift of magnetic
 surfaces, the structure of MHD instabilities will be determined
Описано особливості застосування магнітної діагностики в торсатроні U-2M. Представлено методи врахування впливу металевого оточення на результатах магнітних вимірювань. У ході експериментальної програми на торсатроні U-2M за допомогою магнітної діагностики визначатимуться найбільш важливі характеристики плазми, такі, як величина енерговмісту плазми, енергетичний час життя, введена в плазму потужність, величина струмів Пфірша-Шлюттера, наявність магнітних островів, зсув магнітних поверхонь, структура МГД-нестійкостей.
Описаны особенности применения магнитной диагностики в торсатроне U-2M. Представлены методы учета влияния металлического окружения на результаты магнитных измерений. В ходе экспериментальной программы на торсатроне U-2M с помощью магнитной диагностики будут определяться наиболее важные характеристики плазмы, такие, как величина энергосодержания плазмы, энергетическое время жизни, введенная в плазму мощность, величина токов Пфирша-Шлюттера, наличие магнитных островов, смещение магнитных поверхностей, структура МГД-неустойчивостей.
en
Національний науковий центр «Харківський фізико-технічний інститут» НАН України
Вопросы атомной науки и техники
Диагностика плазмы
Magnetic diagnostics for torsatron U-2M
Магнітна діагностика для торсатрона У-2М
Магнитная диагностика для торсатрона У-2М
Article
published earlier
spellingShingle Magnetic diagnostics for torsatron U-2M
Pashnev, V.K.
Petrushenya, A.A.
Sorokovoy, E.L.
Krasnyj, V.V.
Диагностика плазмы
title Magnetic diagnostics for torsatron U-2M
title_alt Магнітна діагностика для торсатрона У-2М
Магнитная диагностика для торсатрона У-2М
title_full Magnetic diagnostics for torsatron U-2M
title_fullStr Magnetic diagnostics for torsatron U-2M
title_full_unstemmed Magnetic diagnostics for torsatron U-2M
title_short Magnetic diagnostics for torsatron U-2M
title_sort magnetic diagnostics for torsatron u-2m
topic Диагностика плазмы
topic_facet Диагностика плазмы
url https://nasplib.isofts.kiev.ua/handle/123456789/91069
work_keys_str_mv AT pashnevvk magneticdiagnosticsfortorsatronu2m
AT petrushenyaaa magneticdiagnosticsfortorsatronu2m
AT sorokovoyel magneticdiagnosticsfortorsatronu2m
AT krasnyjvv magneticdiagnosticsfortorsatronu2m
AT pashnevvk magnítnadíagnostikadlâtorsatronau2m
AT petrushenyaaa magnítnadíagnostikadlâtorsatronau2m
AT sorokovoyel magnítnadíagnostikadlâtorsatronau2m
AT krasnyjvv magnítnadíagnostikadlâtorsatronau2m
AT pashnevvk magnitnaâdiagnostikadlâtorsatronau2m
AT petrushenyaaa magnitnaâdiagnostikadlâtorsatronau2m
AT sorokovoyel magnitnaâdiagnostikadlâtorsatronau2m
AT krasnyjvv magnitnaâdiagnostikadlâtorsatronau2m