Prolongation of Safe Operation of the K-1000-60/3000 Turbine Power Unit after Damage to the HPC Rotor
Currently, when large-scale military actions are taking place on the territory of Ukraine, the inclusion of the domestic energy system in the European one is a reliable component of providing electricity to the country's energy market. However, according to experts, uninterrupted and safe opera...
Saved in:
| Date: | 2024 |
|---|---|
| Main Authors: | Черноусенко, О. Ю., Пешко, В. А., Усатий, О. П. |
| Format: | Article |
| Language: | English Ukrainian |
| Published: |
Інститут енергетичних машин і систем ім. А. М. Підгорного Національної академії наук України
2024
|
| Online Access: | https://journals.uran.ua/jme/article/view/302410 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Energy Technologies & Resource Saving |
Institution
Energy Technologies & Resource SavingSimilar Items
-
Prolongation of Safe Operation of the K-1000-60/3000 Turbine Power Unit after Damage to the HPC Rotor
by: Черноусенко, О. Ю., et al.
Published: (2024) -
Changes in the Thermal and Stress-Strain State of the HPC Rotor of a Powerful NPP Turbine after the Blades Damage
by: Черноусенко, О. Ю., et al.
Published: (2023) -
Changes in the Thermal and Stress-Strain State of the HPC Rotor of a Powerful NPP Turbine after the Blades Damage
by: Черноусенко, О. Ю., et al.
Published: (2023) -
Changes in the Thermal and Stress-Strain State of the HPC Rotor of a Powerful NPP Turbine after the Blades Damage
by: O. Y. Chernousenko, et al.
Published: (2023) -
Assessment of Resource Parameters of the Extended Operation High-Pressure Rotor of the K-1000-60/3000 Turbine
by: Chernousenko, Olha Yu., et al.
Published: (2019)