Axial internal forces in power transformer active part elements after short circuit
The paper studies core type transformers, in which radial and axial electromagnetic short circuit forces act upon winding coils. In the conductors, these forces cause stresses due to bending in the radial and axial directions, as well as tensile or compressive stresses. Due to plastic deformations o...
Saved in:
| Date: | 2015 |
|---|---|
| Main Author: | Лазарев, И. В. |
| Format: | Article |
| Language: | Russian |
| Published: |
Інститут енергетичних машин і систем ім. А. М. Підгорного Національної академії наук України
2015
|
| Subjects: | |
| Online Access: | https://journals.uran.ua/jme/article/view/46685 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Energy Technologies & Resource Saving |
Institution
Energy Technologies & Resource SavingSimilar Items
-
Axial internal forces in power transformer active part elements after short circuit
by: Лазарев, И. В.
Published: (2015) -
Axial internal forces in power transformer active part elements after short circuit
by: Лазарев, И. В., et al.
Published: (2015) -
Axial internal forces in power transformer active part elements after short circuit
by: Лазарев, И. В., et al.
Published: (2015) -
Axial internal forces in power transformer active part elements under windings clamping, variation of temperature and insulating materials moisture content
by: Лазарев, И. В.
Published: (2014) -
Axial internal forces in power transformer active part elements under windings clamping, variation of temperature and insulating materials moisture content
by: Лазарев, И. В.
Published: (2014)