Thermal state of the rotor winding of the turbogenerator with direct hydrogen cooling
The temperature field of the rotor of the synchronous turbogenerator is investigated. The temperature distributions in rotor windings of 300 and 550-MW turbogenerators with direct hydrogen cooling of rotor winding are obtained. The transition to more power is implemented by increasing the hydrogen p...
Gespeichert in:
| Datum: | 2015 |
|---|---|
| Hauptverfasser: | Кобзарь, К. А., Гакал, П. Г., Овсянникова, Е. А., Третьяк, А. В. |
| Format: | Artikel |
| Sprache: | Russian |
| Veröffentlicht: |
Інститут енергетичних машин і систем ім. А. М. Підгорного Національної академії наук України
2015
|
| Schlagworte: | |
| Online Zugang: | https://journals.uran.ua/jme/article/view/57507 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Energy Technologies & Resource Saving |
Institution
Energy Technologies & Resource SavingÄhnliche Einträge
-
Thermal state of the rotor winding of the turbogenerator with direct hydrogen cooling
von: Кобзарь, К. А., et al.
Veröffentlicht: (2015) -
Development Thermal state of the rotor of the turbogenerator with direct hydrogen cooling
von: Овсянникова, Е. А.
Veröffentlicht: (2017) -
Development Thermal state of the rotor of the turbogenerator with direct hydrogen cooling
von: Овсянникова, Е. А.
Veröffentlicht: (2017) -
TURBOGENERATOR ROTOR HEATING IN PRESENCE OF ROTOR WINDING DEFECTS AND EXCITATION CURRENT FORCING
von: Vaskovskyi, Yu. M., et al.
Veröffentlicht: (2020) -
Recognition of emergency situations of large hydrogenerators and turbogenerators by multi factors analysis of complicated stressed states of units and component parts
von: Вакуленко, А. Н., et al.
Veröffentlicht: (2015)