ДОСЛІДЖЕННЯ ВПЛИВУ ВИПАДАННЯ ВОЛОГИ НА ПОВЕРХНІ ЦИЛІНДРА НА ВИЗНАЧЕННЯ КОЕФІЦІЄНТА ТЕПЛОВІДДАЧІ ПОВІТРЯ ПРИ ЗАСТОСУВАННІ МЕТОДУ ТАНЕННЯ ЛЬОДУ
Circular cylinders with cross-flow are a component of many technical devices in power engineering, heat engineering and chemical technology. For the intensification of external heat exchange, various types of ribs are widely used, the use of which is associated with a large metal capacity of the equ...
Saved in:
| Date: | 2018 |
|---|---|
| Main Authors: | , , , |
| Format: | Article |
| Language: | Ukrainian |
| Published: |
Institute of Engineering Thermophysics of NAS of Ukraine
2018
|
| Online Access: | https://ihe.nas.gov.ua/index.php/journal/article/view/319 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Thermophysics and Thermal Power Engineering |
Institution
Thermophysics and Thermal Power Engineering| id |
oai:ojs2.ihenasgovua.s43.yourdomain.com.ua:article-319 |
|---|---|
| record_format |
ojs |
| institution |
Thermophysics and Thermal Power Engineering |
| baseUrl_str |
|
| datestamp_date |
2019-04-07T05:08:20Z |
| collection |
OJS |
| language |
Ukrainian |
| format |
Article |
| author |
Khalatov, A. A. Kovalenko, G.V. Mulyarchuk, M. A. Stepanyuk, O. Yu. |
| spellingShingle |
Khalatov, A. A. Kovalenko, G.V. Mulyarchuk, M. A. Stepanyuk, O. Yu. ДОСЛІДЖЕННЯ ВПЛИВУ ВИПАДАННЯ ВОЛОГИ НА ПОВЕРХНІ ЦИЛІНДРА НА ВИЗНАЧЕННЯ КОЕФІЦІЄНТА ТЕПЛОВІДДАЧІ ПОВІТРЯ ПРИ ЗАСТОСУВАННІ МЕТОДУ ТАНЕННЯ ЛЬОДУ |
| author_facet |
Khalatov, A. A. Kovalenko, G.V. Mulyarchuk, M. A. Stepanyuk, O. Yu. |
| author_sort |
Khalatov, A. A. |
| title |
ДОСЛІДЖЕННЯ ВПЛИВУ ВИПАДАННЯ ВОЛОГИ НА ПОВЕРХНІ ЦИЛІНДРА НА ВИЗНАЧЕННЯ КОЕФІЦІЄНТА ТЕПЛОВІДДАЧІ ПОВІТРЯ ПРИ ЗАСТОСУВАННІ МЕТОДУ ТАНЕННЯ ЛЬОДУ |
| title_short |
ДОСЛІДЖЕННЯ ВПЛИВУ ВИПАДАННЯ ВОЛОГИ НА ПОВЕРХНІ ЦИЛІНДРА НА ВИЗНАЧЕННЯ КОЕФІЦІЄНТА ТЕПЛОВІДДАЧІ ПОВІТРЯ ПРИ ЗАСТОСУВАННІ МЕТОДУ ТАНЕННЯ ЛЬОДУ |
| title_full |
ДОСЛІДЖЕННЯ ВПЛИВУ ВИПАДАННЯ ВОЛОГИ НА ПОВЕРХНІ ЦИЛІНДРА НА ВИЗНАЧЕННЯ КОЕФІЦІЄНТА ТЕПЛОВІДДАЧІ ПОВІТРЯ ПРИ ЗАСТОСУВАННІ МЕТОДУ ТАНЕННЯ ЛЬОДУ |
| title_fullStr |
ДОСЛІДЖЕННЯ ВПЛИВУ ВИПАДАННЯ ВОЛОГИ НА ПОВЕРХНІ ЦИЛІНДРА НА ВИЗНАЧЕННЯ КОЕФІЦІЄНТА ТЕПЛОВІДДАЧІ ПОВІТРЯ ПРИ ЗАСТОСУВАННІ МЕТОДУ ТАНЕННЯ ЛЬОДУ |
| title_full_unstemmed |
ДОСЛІДЖЕННЯ ВПЛИВУ ВИПАДАННЯ ВОЛОГИ НА ПОВЕРХНІ ЦИЛІНДРА НА ВИЗНАЧЕННЯ КОЕФІЦІЄНТА ТЕПЛОВІДДАЧІ ПОВІТРЯ ПРИ ЗАСТОСУВАННІ МЕТОДУ ТАНЕННЯ ЛЬОДУ |
| title_sort |
дослідження впливу випадання вологи на поверхні циліндра на визначення коефіцієнта тепловіддачі повітря при застосуванні методу танення льоду |
| title_alt |
INFLUENCE MOISTURE FORMATION ON CYLINDER SURFACE ON THE DETERMINATION OF HEAT TRANSFER COEFFICIENT AIR DURING APPLICATION OF THE METHOD OF MELTING ICE ВЛИЯНИЕ ВЫПАДЕНИЕ ВЛАГИ НА ПОВЕРХНОСТИ ЦИЛИНДРА НА ОПРЕДЕЛЕНИЯ КОЭФФИЦИЕНТОВ ТЕПЛООТДАЧИ ВОЗДУХА ПРИ ПРИМЕНЕНИИ МЕТОДА ТАЯНИЯ ЛЬДА |
| description |
Circular cylinders with cross-flow are a component of many technical devices in power engineering, heat engineering and chemical technology.
For the intensification of external heat exchange, various types of ribs are widely used, the use of which is associated with a large metal capacity of the equipment. Application of holes on the heat exchange surface can significantly improve the thermohydraulic and mass-grossing characteristics of heat and mass equipment. A simple and effective way of intensifying heat transfer is the spiral groove on the outer surface of the pipe.
The purpose of this work is to develop a method for determining the average coefficient of heat transfer by the method of melting ice, taking into account the moisture that falls on the surface of the cylinder-calorimeter. The research was carried out in the range of the Reynolds number change, calculated from the outside diameter of the pipe, from 2000 to 17000.
In this paper, the method of determining the average coefficient of heat transfer by the method of melting of ice at the cross-flow of a round cylinder is specified. It is shown that ignoring the air humidity flowing through the cylinder-calorimeter can lead to a large error in determining the average coefficient of heat transfer, especially when air humidity is more than 53%. |
| publisher |
Institute of Engineering Thermophysics of NAS of Ukraine |
| publishDate |
2018 |
| url |
https://ihe.nas.gov.ua/index.php/journal/article/view/319 |
| work_keys_str_mv |
AT khalatovaa influencemoistureformationoncylindersurfaceonthedeterminationofheattransfercoefficientairduringapplicationofthemethodofmeltingice AT kovalenkogv influencemoistureformationoncylindersurfaceonthedeterminationofheattransfercoefficientairduringapplicationofthemethodofmeltingice AT mulyarchukma influencemoistureformationoncylindersurfaceonthedeterminationofheattransfercoefficientairduringapplicationofthemethodofmeltingice AT stepanyukoyu influencemoistureformationoncylindersurfaceonthedeterminationofheattransfercoefficientairduringapplicationofthemethodofmeltingice AT khalatovaa vliânievypadenievlaginapoverhnosticilindranaopredeleniâkoéfficientovteplootdačivozduhapriprimeneniimetodataâniâlʹda AT kovalenkogv vliânievypadenievlaginapoverhnosticilindranaopredeleniâkoéfficientovteplootdačivozduhapriprimeneniimetodataâniâlʹda AT mulyarchukma vliânievypadenievlaginapoverhnosticilindranaopredeleniâkoéfficientovteplootdačivozduhapriprimeneniimetodataâniâlʹda AT stepanyukoyu vliânievypadenievlaginapoverhnosticilindranaopredeleniâkoéfficientovteplootdačivozduhapriprimeneniimetodataâniâlʹda AT khalatovaa doslídžennâvplivuvipadannâvologinapoverhnícilíndranaviznačennâkoefícíêntateplovíddačípovítrâprizastosuvannímetodutanennâlʹodu AT kovalenkogv doslídžennâvplivuvipadannâvologinapoverhnícilíndranaviznačennâkoefícíêntateplovíddačípovítrâprizastosuvannímetodutanennâlʹodu AT mulyarchukma doslídžennâvplivuvipadannâvologinapoverhnícilíndranaviznačennâkoefícíêntateplovíddačípovítrâprizastosuvannímetodutanennâlʹodu AT stepanyukoyu doslídžennâvplivuvipadannâvologinapoverhnícilíndranaviznačennâkoefícíêntateplovíddačípovítrâprizastosuvannímetodutanennâlʹodu |
| first_indexed |
2025-12-17T13:55:18Z |
| last_indexed |
2025-12-17T13:55:18Z |
| _version_ |
1851763949275447296 |
| spelling |
oai:ojs2.ihenasgovua.s43.yourdomain.com.ua:article-3192019-04-07T05:08:20Z INFLUENCE MOISTURE FORMATION ON CYLINDER SURFACE ON THE DETERMINATION OF HEAT TRANSFER COEFFICIENT AIR DURING APPLICATION OF THE METHOD OF MELTING ICE ВЛИЯНИЕ ВЫПАДЕНИЕ ВЛАГИ НА ПОВЕРХНОСТИ ЦИЛИНДРА НА ОПРЕДЕЛЕНИЯ КОЭФФИЦИЕНТОВ ТЕПЛООТДАЧИ ВОЗДУХА ПРИ ПРИМЕНЕНИИ МЕТОДА ТАЯНИЯ ЛЬДА ДОСЛІДЖЕННЯ ВПЛИВУ ВИПАДАННЯ ВОЛОГИ НА ПОВЕРХНІ ЦИЛІНДРА НА ВИЗНАЧЕННЯ КОЕФІЦІЄНТА ТЕПЛОВІДДАЧІ ПОВІТРЯ ПРИ ЗАСТОСУВАННІ МЕТОДУ ТАНЕННЯ ЛЬОДУ Khalatov, A. A. Kovalenko, G.V. Mulyarchuk, M. A. Stepanyuk, O. Yu. Circular cylinders with cross-flow are a component of many technical devices in power engineering, heat engineering and chemical technology. For the intensification of external heat exchange, various types of ribs are widely used, the use of which is associated with a large metal capacity of the equipment. Application of holes on the heat exchange surface can significantly improve the thermohydraulic and mass-grossing characteristics of heat and mass equipment. A simple and effective way of intensifying heat transfer is the spiral groove on the outer surface of the pipe. The purpose of this work is to develop a method for determining the average coefficient of heat transfer by the method of melting ice, taking into account the moisture that falls on the surface of the cylinder-calorimeter. The research was carried out in the range of the Reynolds number change, calculated from the outside diameter of the pipe, from 2000 to 17000. In this paper, the method of determining the average coefficient of heat transfer by the method of melting of ice at the cross-flow of a round cylinder is specified. It is shown that ignoring the air humidity flowing through the cylinder-calorimeter can lead to a large error in determining the average coefficient of heat transfer, especially when air humidity is more than 53%. Круглые цилиндры при поперечном обтекании является составным элементом многих технических устройств в энергетике, теплотехнике и химической технологии. Для интенсификации внешнего теплообмена широко применяются различные виды ребер, использование которых связано с большой металлоемкостью оборудования. Применение углублений на теплообменной поверхности позволяет существенно улучшить теплогидравлические и массогабаритные характеристики тепломассообменного оборудования. Простым и эффективным способом интенсификации теплообмена является спиральная канавка на внешней поверхности трубы. Целью данной работы является разработка методики определения среднего коэффициента теплоотдачи методом таяния льда с учетом влаги, которая выпадает на поверхности цилиндра-калориметра. Исследование выполнялось в диапазоне изменения числа Рейнольдса, рассчитанного по наружному диаметру трубы, от 2000 до 17000. В данной работе уточнено методику определения среднего коэффициента теплоотдачи методом таяния льда при поперечном обтекании круглого цилиндра. Показано, что неучет влажности воздуха обтекает цилиндр-калориметр, может привести к большой погрешности при определении среднего коэффициента теплоотдачи, особенно при влажности воздуха более 53%. Круглі циліндри при поперечному обтіканні є складовим елементом багатьох технічних пристроїв в енергетиці, теплотехніці і хімічній технології. Для інтенсифікації зовнішнього теплообміну широко застосовуються різні види ребер, використання яких пов'язане з великою металоємністю обладнання. Застосування заглиблень на теплообмінній поверхні дозволяє істотно поліпшити теплогідравлічні і масогабаритні характеристики тепломасообмінного обладнання. Простим і ефективним способом інтенсифікації теплообміну є спіральна канавка на зовнішній поверхні труби. Метою даної роботи є розробка методики визначення середнього коефіцієнта тепловіддачі методом танення льоду з урахуванням вологи, яка випадає на поверхні циліндра-калориметра. Дослідження виконувалось в діапазоні зміни числа Рейнольдса, розрахованого по зовнішньому діаметру труби, від 2000 до 17000. У даній роботі Уточнено методику визначення середнього коефіцієнту тепловіддачі методом танення льоду при поперечному обтіканні круглого циліндра. Показано, що неврахування вологості повітря, що обтікає циліндр-калориметр, може привести до великої похибки при визначенні середнього коефіцієнту тепловіддачі, особливо при вологості повітря більше 53%. Institute of Engineering Thermophysics of NAS of Ukraine 2018-12-20 Article Article application/pdf https://ihe.nas.gov.ua/index.php/journal/article/view/319 10.31472/ttpe.1.2019.1 Thermophysics and Thermal Power Engineering; Vol 41 No 1 (2019): Thermophysics and Thermal Power Engineering; 5-10 Теплофизика и Теплоэнергетика; Vol 41 No 1 (2019): Thermophysics and Thermal Power Engineering; 5-10 Теплофізика та Теплоенергетика; Vol 41 No 1 (2019): Thermophysics and Thermal Power Engineering; 5-10 2663-7235 10.31472/ttpe.1.2019 uk https://ihe.nas.gov.ua/index.php/journal/article/view/319/262 |