ВПЛИВ ТЕМПЕРАТУРИ ВОДИ НА ВХОДІ В ПАРОГЕНЕРУЧИЙ КАНАЛ НА СТІЙКІСТЬ ДВОХФАЗНОГО ПОТОКУ

The paper considers the influence of the coolant temperature on stability of the flow in the closed loop of thermal-hydraulic test bench in the natural circulation mode. The loop includes a lifting section with a heated and unheated zone, condenser and lowering section where the single-phase coolant...

Full description

Saved in:
Bibliographic Details
Date:2019
Main Author: Kovetskaya, M.M.
Format: Article
Language:Russian
Published: Institute of Engineering Thermophysics of NAS of Ukraine 2019
Online Access:https://ihe.nas.gov.ua/index.php/journal/article/view/335
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Thermophysics and Thermal Power Engineering

Institution

Thermophysics and Thermal Power Engineering