ЗАСТОСУВАННЯ ЗАГЛИБЛЕНЬ ТА ГВИНТОВИХ КАНАВОК НА ЗОВНІШНІЙ ПОВЕРХНІ ТРУБ ДЛЯ ПІДВИЩЕННЯ ТЕПЛОГІДРАВЛІЧНОЇ ЕФЕКТИВНОСТІ ТРУБНИХ ПУЧКІВ ПРИ ПОПЕРЕЧНОМУ ОБТІКАННІ

The flow structure and thermo-hydraulic efficiency of cross flow of tube bundles with dimples and helical grooves have been analyzed. The Reynolds number range (103-104) was typical for industrial heat exсhangers. It was found that dimples and grooves decrease scientifically the cylinder wake area a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2022
Hauptverfasser: Khalatov, А.А., Borisov, І.І., Kovalenko, G., Muliarchuk, M.
Format: Artikel
Sprache:Ukrainian
Veröffentlicht: Institute of Engineering Thermophysics of NAS of Ukraine 2022
Online Zugang:https://ihe.nas.gov.ua/index.php/journal/article/view/497
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Thermophysics and Thermal Power Engineering

Institution

Thermophysics and Thermal Power Engineering
Beschreibung
Zusammenfassung:The flow structure and thermo-hydraulic efficiency of cross flow of tube bundles with dimples and helical grooves have been analyzed. The Reynolds number range (103-104) was typical for industrial heat exсhangers. It was found that dimples and grooves decrease scientifically the cylinder wake area and reduces the hydraulic losses. The heat transfer augmentation in five-row tube bundle by dimples is 35-40% while pressure drop increase by 10-15%. The hydraulic resistance of two-row bundle of tube with helical grooves is 20% lower than that of a smooth tube bundle, while heat transfer augmentation is absent. The value of Reynolds analogy factor for tube bundles with dimples and helical grooves exceeds unity. The high thermo-hydraulic efficiency of tube bundles with dimples and helical grooves, allows us to recommend it for practical use in the development of modern heat exchange equipment of the tubular type.