Оцінка еквівалентної дози на руки маніпуляційного персоналу відділення ПЕТ/КТ
The paper compares information on the values of the equivalent dose to hands that are read from ring DXT-RAD thermoluminescent dosimeters of the manipulation nurse in the Positron Emission Computed Tomography Department of the All-Ukrainian Center for Radiosurgery at the Feofania Clinical Hospital w...
Збережено в:
Дата: | 2022 |
---|---|
Автори: | , , , |
Формат: | Стаття |
Мова: | Ukrainian |
Опубліковано: |
State Scientific and Technical Center for Nuclear and Radiation Safety
2022
|
Онлайн доступ: | https://nuclear-journal.com/index.php/journal/article/view/1009 |
Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
Назва журналу: | Nuclear and Radiation Safety |
Репозитарії
Nuclear and Radiation Safetyid |
oai:ojs2.nuclear-journal.com:article-1009 |
---|---|
record_format |
ojs |
institution |
Nuclear and Radiation Safety |
collection |
OJS |
language |
Ukrainian |
format |
Article |
author |
Kudriashova, Ye. Bondar, B. Kmetyuk, Ya. Viskov, O. |
spellingShingle |
Kudriashova, Ye. Bondar, B. Kmetyuk, Ya. Viskov, O. Оцінка еквівалентної дози на руки маніпуляційного персоналу відділення ПЕТ/КТ |
author_facet |
Kudriashova, Ye. Bondar, B. Kmetyuk, Ya. Viskov, O. |
author_sort |
Kudriashova, Ye. |
title |
Оцінка еквівалентної дози на руки маніпуляційного персоналу відділення ПЕТ/КТ |
title_short |
Оцінка еквівалентної дози на руки маніпуляційного персоналу відділення ПЕТ/КТ |
title_full |
Оцінка еквівалентної дози на руки маніпуляційного персоналу відділення ПЕТ/КТ |
title_fullStr |
Оцінка еквівалентної дози на руки маніпуляційного персоналу відділення ПЕТ/КТ |
title_full_unstemmed |
Оцінка еквівалентної дози на руки маніпуляційного персоналу відділення ПЕТ/КТ |
title_sort |
оцінка еквівалентної дози на руки маніпуляційного персоналу відділення пет/кт |
title_alt |
Evaluation of the Nursing PET-CT Staff Hand Dose Equivalent |
description |
The paper compares information on the values of the equivalent dose to hands that are read from ring DXT-RAD thermoluminescent dosimeters of the manipulation nurse in the Positron Emission Computed Tomography Department of the All-Ukrainian Center for Radiosurgery at the Feofania Clinical Hospital with calculations of the equivalent dose to hands that are performed using the VARSKIN+ computer code.
Personnel who manipulate radiopharmaceuticals in the Positron Emission Computed Tomography Department are under permanent individual dosimetric control using thermoluminescent dosimeters to determine the effective dose from beta and secondary photon radiation created by the 18F radionuclide in the 2-[18F] -2-deoxy-D-glucose, as well as ring dosimeters to determine the equivalent dose to the hands for comparison with category A dose limits.
During the study, information from the ring dosimeters of three manipulation nurses of the Positron Emission Computed Tomography Department was used regarding the dose accumulated over ten months. Over this period, information was extracted from the department's documents, in particular from journal entries, about the daily number of manipulations performed, the amount of activity administered to each patient, the total activity of radiopharmaceuticals, the evidence of the use of protective equipment during the manipulations, reports of cases involving radioactive substance contact with skin, gloves, etc., which can affect the measured dose on hands. The average time spent on each stage of manipulation with 18F-FDG was determined experimentally.
Comparison of the calculated data and data obtained in the processing of thermoluminescent dosimeters for the same time, taking into account the number of operations performed by the staff and the amount of activity prepared for administration to patients, allowed determining the possibility and effectiveness of using calculations for planning and evaluation of the equivalent dose in manipulations at the Positron Emission Computed Tomography Department, assessing the need for additional local protection against ionizing radiation for hands during injections or optimization of manipulation procedures and determining the obligation to evaluate equivalent doses using thermoluminescent dosimeters. |
publisher |
State Scientific and Technical Center for Nuclear and Radiation Safety |
publishDate |
2022 |
url |
https://nuclear-journal.com/index.php/journal/article/view/1009 |
work_keys_str_mv |
AT kudriashovaye evaluationofthenursingpetctstaffhanddoseequivalent AT bondarb evaluationofthenursingpetctstaffhanddoseequivalent AT kmetyukya evaluationofthenursingpetctstaffhanddoseequivalent AT viskovo evaluationofthenursingpetctstaffhanddoseequivalent AT kudriashovaye ocínkaekvívalentnoídozinarukimanípulâcíjnogopersonaluvíddílennâpetkt AT bondarb ocínkaekvívalentnoídozinarukimanípulâcíjnogopersonaluvíddílennâpetkt AT kmetyukya ocínkaekvívalentnoídozinarukimanípulâcíjnogopersonaluvíddílennâpetkt AT viskovo ocínkaekvívalentnoídozinarukimanípulâcíjnogopersonaluvíddílennâpetkt |
first_indexed |
2024-09-01T17:41:38Z |
last_indexed |
2024-09-01T17:41:38Z |
_version_ |
1809016420820844544 |
spelling |
oai:ojs2.nuclear-journal.com:article-10092023-01-17T11:37:33Z Evaluation of the Nursing PET-CT Staff Hand Dose Equivalent Оцінка еквівалентної дози на руки маніпуляційного персоналу відділення ПЕТ/КТ Kudriashova, Ye. Bondar, B. Kmetyuk, Ya. Viskov, O. The paper compares information on the values of the equivalent dose to hands that are read from ring DXT-RAD thermoluminescent dosimeters of the manipulation nurse in the Positron Emission Computed Tomography Department of the All-Ukrainian Center for Radiosurgery at the Feofania Clinical Hospital with calculations of the equivalent dose to hands that are performed using the VARSKIN+ computer code. Personnel who manipulate radiopharmaceuticals in the Positron Emission Computed Tomography Department are under permanent individual dosimetric control using thermoluminescent dosimeters to determine the effective dose from beta and secondary photon radiation created by the 18F radionuclide in the 2-[18F] -2-deoxy-D-glucose, as well as ring dosimeters to determine the equivalent dose to the hands for comparison with category A dose limits. During the study, information from the ring dosimeters of three manipulation nurses of the Positron Emission Computed Tomography Department was used regarding the dose accumulated over ten months. Over this period, information was extracted from the department's documents, in particular from journal entries, about the daily number of manipulations performed, the amount of activity administered to each patient, the total activity of radiopharmaceuticals, the evidence of the use of protective equipment during the manipulations, reports of cases involving radioactive substance contact with skin, gloves, etc., which can affect the measured dose on hands. The average time spent on each stage of manipulation with 18F-FDG was determined experimentally. Comparison of the calculated data and data obtained in the processing of thermoluminescent dosimeters for the same time, taking into account the number of operations performed by the staff and the amount of activity prepared for administration to patients, allowed determining the possibility and effectiveness of using calculations for planning and evaluation of the equivalent dose in manipulations at the Positron Emission Computed Tomography Department, assessing the need for additional local protection against ionizing radiation for hands during injections or optimization of manipulation procedures and determining the obligation to evaluate equivalent doses using thermoluminescent dosimeters. У статті порівняно інформацію щодо значень еквівалентної дози на руки, зчитаних з кільцевих термолюмінесцентних дозиметрів маніпуляційних медичних сестер відділення позитронно-емісійної комп’ютерної томографії Всеукраїнського центру радіохірургії Клінічної лікарні «Феофанія» Державного управління справами, із розрахунками еквівалентної дози на руки, виконаних за допомогою комп’ютерного коду VARSKIN+. Персонал, який здійснює маніпуляції із радіофармпрепаратом у відділенні позитронно-емісійної комп’ютерної томографії, знаходиться на постійному індивідуальному дозиметричному контролі із використанням термолюмінесцентних дозиметрів для визначення ефективної дози від бета- та вторинного фотонного випромінювання, що створюється радіонуклідом 18F у складі радіофармпрепарату 2-[18F]Fluoro-2-deoxy-D-glucose, а також кільцевих дозиметрів для визначення еквівалентної дози на руки для порівняння із дозовими лімітами персоналу категорії А. Під час дослідження була використана інформація з дозиметрів-кілець трьох маніпуляційних медичних сестер відділення позитронно-емісійної комп’ютерної томографії Всеукраїнського центру радіохірургії Клінічної лікарні «Феофанія» Державного управління справами щодо дози, накопиченої за десять місяців. За цей період із документації відділення, зокрема із записів в журналах, була виокремлена інформація про щоденну кількість проведених маніпуляцій, як-то введеної активності кожному пацієнту, загальної активності радіофармпрепарату, факту використання захисних засобів при проведенні маніпуляцій, повідомлень про випадки контакту радіоактивної речовини зі шкірою, рукавичками, інше, що може вплинути на значення виміряної дози на кисті рук. Експериментально було визначено усереднений час, що витрачається на кожний етап маніпуляції з радіофармпрепаратом. Порівняння розрахункових даних та даних, отриманих під час обробки термолюмінесцентних дозиметрів за один і той самий час, враховуючи кількість операцій, що були проведені персоналом, та величину активності, підготовленої для введення пацієнтам, дозволило визначитись із можливістю та ефективністю використання розрахунків для планування та оцінки еквівалентної дози під час проведення маніпуляцій у відділенні позитронно-емісійної комп’ютерної томографії медичних центрів, оцінити потребу в додатковому локальному захисті від іонізуючого випромінювання для рук під час проведення ін’єкцій чи оптимізації процедур маніпуляції, визначитись з обов’язковістю оцінювання еквівалентних доз за допомогою термолюмінесцентних дозиметрів. State Scientific and Technical Center for Nuclear and Radiation Safety 2022-12-21 Article Article application/pdf https://nuclear-journal.com/index.php/journal/article/view/1009 10.32918/nrs.2022.4(96).09 Nuclear and Radiation Safety; No 4(96) (2022): Nuclear and Radiation Safety; 71-82 Ядерна та радіаційна безпека; № 4(96) (2022): Ядерна та радіаційна безпека; 71-82 2073-6231 uk https://nuclear-journal.com/index.php/journal/article/view/1009/739 |