Вплив дозування цинку на потужність дози від петель першого контуру для енергоблоків PWR і прогнозні оцінки для ВВЕР-1000

The paper analyzed the advisability of zinc injection into the VVER primary system coolant in order to minimize radioactive fields of equipment. In the western NPPs with PWR, zinc injection into the coolant leads to permanent decrease of dose rates caused by radioactive cobalt. Zinc is introduced in...

Full description

Saved in:
Bibliographic Details
Date:2017
Main Authors: Maltseva, T., Horpinchenko, O., Gumenyuk, D.
Format: Article
Language:English
Published: State Scientific and Technical Center for Nuclear and Radiation Safety 2017
Online Access:https://nuclear-journal.com/index.php/journal/article/view/134
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Nuclear and Radiation Safety

Institution

Nuclear and Radiation Safety