КОРИГУВАННЯ РЕЖИМУ СЛАБКОЇ ЕЛЕКТРИЧНОЇ МЕРЕЖІ ПРИ ЗАПУСКУ ВІД НЕЇ ЕЛЕКТРОДВИГУНА ЗІСТАВНОЇ ПОТУЖНОСТІ

The regime of a weak electric network  when starting the electric motor is considered when its power is comparable with the power of the network.To compensate the starting currents of the electric motor, it is proposed to use a device containing a bridge thyristor controlled reactive power...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2017
Hauptverfasser: Чиженко, О.І., Трач, І.В.
Format: Artikel
Sprache:Ukrainian
Veröffentlicht: Інститут електродинаміки Національної академії наук України 2017
Schlagworte:
Online Zugang:https://prc.ied.org.ua/index.php/proceedings/article/view/227
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Proceedings of the Institute of Electrodynamics of the National Academy of Sciences of Ukraine

Institution

Proceedings of the Institute of Electrodynamics of the National Academy of Sciences of Ukraine
Beschreibung
Zusammenfassung:The regime of a weak electric network  when starting the electric motor is considered when its power is comparable with the power of the network.To compensate the starting currents of the electric motor, it is proposed to use a device containing a bridge thyristor controlled reactive power compensator  and LC filters of higher current harmonics. A model of an electric network with an active-inductive load is considered, from which a direct start of an induction motor is carried out in the absence of a mechanical load on its shaft.The parameters of the TRK filter are selected.The currents and voltages on the elements of the model are analyzed. The advantages of using the" reactive power compensator-filter" device for the purpose of protecting the electrical equipment from starting currents and voltage drops, as well as guaranteed start of the electric motor are shown. References 8, figures 4, table.