ПРОБЛЕМЫ ОХЛАЖДЕНИЯ ТУРБОГЕНЕРАТОРОВ БОЛЬШОЙ И СРЕДНЕЙ МОЩНОСТИ

Turbogenerators large and medium power cooling system disadvantages are identified. The main problems of the stator core cooling are identified also. The variant of heat transfer enhancement in the stator core is proposed. The variant bases on the cooling channels design, taking into account the air...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2012
Hauptverfasser: Грубой, А.П., Третьяк, А.В.
Format: Artikel
Sprache:Ukrainian
Veröffentlicht: Інститут електродинаміки НАН України, Київ 2012
Schlagworte:
Online Zugang:https://techned.org.ua/index.php/techned/article/view/1260
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Technical Electrodynamics

Institution

Technical Electrodynamics
Beschreibung
Zusammenfassung:Turbogenerators large and medium power cooling system disadvantages are identified. The main problems of the stator core cooling are identified also. The variant of heat transfer enhancement in the stator core is proposed. The variant bases on the cooling channels design, taking into account the air distribution and heat load in the bars. As a result, proposed design provides the maximal bars temperature decreasing on the 5oC and insulation lifetime As the bars have minimum lifetime in turbogenerator design, that is why given improvement makes better reliability of the design. References 2, figure 1.