ІМІТАЦІЙНА МОДЕЛЬ ТА АЛГОРИТМ КЕРУВАННЯ АВТОНОМНОЮ ГІДРО-ВІТРОВОЮ СИСТЕМОЮ ЕЛЕКТРОЖИВЛЕННЯ

A new configuration of a three-phase isolated hydro-wind system (IHWS) is considered. The IHWS contains a driven by a regulated hydraulic turbine synchronous generator with electromagnetic excitation, an induction generator with a short circuit rotor driven by an unregulated wind turbine, compensati...

Full description

Saved in:
Bibliographic Details
Date:2020
Main Authors: Мазуренко, Л.І., Василів, К.М., Джура, О.В., Коцюруба, А.В.
Format: Article
Language:Ukrainian
Published: Інститут електродинаміки НАН України, Київ 2020
Subjects:
Online Access:https://techned.org.ua/index.php/techned/article/view/235
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Technical Electrodynamics

Institution

Technical Electrodynamics
Description
Summary:A new configuration of a three-phase isolated hydro-wind system (IHWS) is considered. The IHWS contains a driven by a regulated hydraulic turbine synchronous generator with electromagnetic excitation, an induction generator with a short circuit rotor driven by an unregulated wind turbine, compensating capacitor bank and regulated dump load fed through an active rectifier. An algorithm for two-level stabilization of the electric frequency in the system is developed. Using the developed simulation model of IHWS, a mathematical simulation of the IHWS electromechanical processes has been performed for a load step and fixed wind speed. The simulation results showed the stable operation of the system in steady-state operating modes and tracking the reference electric frequency levels. References 17, fig. 5, table 1.