ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ
The idea of distributed active filtration is to compensate for the currents of higher harmonics and undesirable components of the power of the main network with inverters of renewable energy converters of the connected microgrid, which have reserves of apparent power. For the convenience of distribu...
Saved in:
| Date: | 2022 |
|---|---|
| Main Authors: | , , , , |
| Format: | Article |
| Language: | English |
| Published: |
Інститут електродинаміки НАН України, Київ
2022
|
| Subjects: | |
| Online Access: | https://techned.org.ua/index.php/techned/article/view/381 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Technical Electrodynamics |
Institution
Technical Electrodynamics| id |
oai:ojs2.ted.new-point.com.ua:article-381 |
|---|---|
| record_format |
ojs |
| institution |
Technical Electrodynamics |
| baseUrl_str |
|
| datestamp_date |
2022-03-21T19:39:03Z |
| collection |
OJS |
| language |
English |
| topic |
потужність небалансу мікромережа стратегія керування паралельним активним фільтром розподілена фільтрація |
| spellingShingle |
потужність небалансу мікромережа стратегія керування паралельним активним фільтром розподілена фільтрація Артеменко, М.Ю. Чопик, В.В. Михальський, В.М. Шаповал, І.А. Поліщук, С.Й. ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ |
| topic_facet |
imbalance power microgrid shunt active filter control strategy distributed filtering потужність небалансу мікромережа стратегія керування паралельним активним фільтром розподілена фільтрація |
| format |
Article |
| author |
Артеменко, М.Ю. Чопик, В.В. Михальський, В.М. Шаповал, І.А. Поліщук, С.Й. |
| author_facet |
Артеменко, М.Ю. Чопик, В.В. Михальський, В.М. Шаповал, І.А. Поліщук, С.Й. |
| author_sort |
Артеменко, М.Ю. |
| title |
ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ |
| title_short |
ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ |
| title_full |
ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ |
| title_fullStr |
ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ |
| title_full_unstemmed |
ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ |
| title_sort |
ідентифікація потужності небалансу трифазної чотирипровідної системи живлення для потреб її розподіленої компенсації |
| title_alt |
THE UNBALANCE POWER IDENTIFICATION IN THE THREE-PHASE FOUR-WIRE POWER SUPPLY SYSTEM FOR THE NEEDS OF ITS DISTRIBUTED COMPENSATION |
| description |
The idea of distributed active filtration is to compensate for the currents of higher harmonics and undesirable components of the power of the main network with inverters of renewable energy converters of the connected microgrid, which have reserves of apparent power. For the convenience of distributed compensation, it is proposed to identify the sinusoidal mode of the three-phase four-wire power system, provided that the symmetric source is six mutually orthogonal components of the three-coordinate vector of line currents. The power of imbalance is shown to be due to four mutually orthogonal components of the three-coordinate vector of line currents with defined reference voltage vectors, each of which is proportional to a separate orthogonal component of the power of imbalance. Integral formulas for determining the scalar values of the four specified orthogonal components of imbalance powers have been obtained, which open the possibility of accounting for their contribution to the deterioration of the quality of electrical energy and the synthesis of control signals for active distributed filtration. The connection between the four specified orthogonal components of the power of imbalance and the parameters of the linear unbalanced load was established, which made it possible to verify these integral formulas using a computer experiment. It is analytically established and experimentally confirmed that the squares of the two orthogonal components of the imbalance powers associated with the current of the neutral wire are included in the decomposition of the square of apparent power and power losses with the multiplier, depending on the ratio of the resistances of the transmission line of the three-phase four-wire power system. References 17, figures 3. |
| publisher |
Інститут електродинаміки НАН України, Київ |
| publishDate |
2022 |
| url |
https://techned.org.ua/index.php/techned/article/view/381 |
| work_keys_str_mv |
AT artemenkomû theunbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation AT čopikvv theunbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation AT mihalʹsʹkijvm theunbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation AT šapovalía theunbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation AT políŝuksj theunbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation AT artemenkomû ídentifíkacíâpotužnostínebalansutrifaznoíčotiriprovídnoísistemiživlennâdlâpotrebíírozpodílenoíkompensacíí AT čopikvv ídentifíkacíâpotužnostínebalansutrifaznoíčotiriprovídnoísistemiživlennâdlâpotrebíírozpodílenoíkompensacíí AT mihalʹsʹkijvm ídentifíkacíâpotužnostínebalansutrifaznoíčotiriprovídnoísistemiživlennâdlâpotrebíírozpodílenoíkompensacíí AT šapovalía ídentifíkacíâpotužnostínebalansutrifaznoíčotiriprovídnoísistemiživlennâdlâpotrebíírozpodílenoíkompensacíí AT políŝuksj ídentifíkacíâpotužnostínebalansutrifaznoíčotiriprovídnoísistemiživlennâdlâpotrebíírozpodílenoíkompensacíí AT artemenkomû unbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation AT čopikvv unbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation AT mihalʹsʹkijvm unbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation AT šapovalía unbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation AT políŝuksj unbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation |
| first_indexed |
2025-09-24T17:38:02Z |
| last_indexed |
2025-09-24T17:38:02Z |
| _version_ |
1844167817573695488 |
| spelling |
oai:ojs2.ted.new-point.com.ua:article-3812022-03-21T19:39:03Z THE UNBALANCE POWER IDENTIFICATION IN THE THREE-PHASE FOUR-WIRE POWER SUPPLY SYSTEM FOR THE NEEDS OF ITS DISTRIBUTED COMPENSATION ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ Артеменко, М.Ю. Чопик, В.В. Михальський, В.М. Шаповал, І.А. Поліщук, С.Й. imbalance power microgrid shunt active filter control strategy distributed filtering потужність небалансу мікромережа стратегія керування паралельним активним фільтром розподілена фільтрація The idea of distributed active filtration is to compensate for the currents of higher harmonics and undesirable components of the power of the main network with inverters of renewable energy converters of the connected microgrid, which have reserves of apparent power. For the convenience of distributed compensation, it is proposed to identify the sinusoidal mode of the three-phase four-wire power system, provided that the symmetric source is six mutually orthogonal components of the three-coordinate vector of line currents. The power of imbalance is shown to be due to four mutually orthogonal components of the three-coordinate vector of line currents with defined reference voltage vectors, each of which is proportional to a separate orthogonal component of the power of imbalance. Integral formulas for determining the scalar values of the four specified orthogonal components of imbalance powers have been obtained, which open the possibility of accounting for their contribution to the deterioration of the quality of electrical energy and the synthesis of control signals for active distributed filtration. The connection between the four specified orthogonal components of the power of imbalance and the parameters of the linear unbalanced load was established, which made it possible to verify these integral formulas using a computer experiment. It is analytically established and experimentally confirmed that the squares of the two orthogonal components of the imbalance powers associated with the current of the neutral wire are included in the decomposition of the square of apparent power and power losses with the multiplier, depending on the ratio of the resistances of the transmission line of the three-phase four-wire power system. References 17, figures 3. Ідея розподіленої активної фільтрації полягає в компенсації струмів вищих гармонік та небажаних складових потужності основної мережі інверторами перетворювачів відновлюваної енергії приєднаної мікромережі, що мають резерви повної потужності. Для зручності розподіленої компенсації запропоновано ідентифікувати синусоїдний режим трифазної чотирипровідної системи живлення за умови симетричного джерела шістьма взаємно ортогональними складовими трикоординатного вектора лінійних струмів. Показано, що потужність небалансу зумовлена чотирма взаємно ортогональними складовими трикоординатного вектора лінійних струмів з визначеними опорними векторами напруг, кожен з яких пропорційний окремій ортогональній складовій потужності небалансу. Отримано інтегральні формули для визначення скалярних значень чотирьох зазначених ортогональних складових потужностей небалансу, що відкривають можливість обліку їх внеску у погіршення якості електричної енергії та синтезу керуючих сигналів для активної розподіленої фільтрації. Встановлено зв’язок між чотирма зазначеними ортогональними складовими потужності небалансу та параметрами лінійного незбалансованого навантаження, що дозволило верифікувати ці інтегральні формули за допомогою комп’ютерного експерименту. Аналітично встановлено та експериментально підтверджено, що квадрати двох ортогональних складових потужностей небалансу, пов’язані зі струмом нейтрального проводу, входять в декомпозиції квадрату повної потужності та потужності втрат із множником, що залежить від співвідношення опорів лінії передачі трифазної чотирипровідної системи живлення. Бібл. 17, рис. 3. Інститут електродинаміки НАН України, Київ 2022-03-19 Article Article application/pdf https://techned.org.ua/index.php/techned/article/view/381 10.15407/techned2022.02.012 Tekhnichna Elektrodynamika; No. 2 (2022): TEKHNICHNA ELEKTRODYNAMIKA; 012 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; № 2 (2022): ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; 012 2218-1903 1607-7970 10.15407/techned2022.02 en https://techned.org.ua/index.php/techned/article/view/381/306 Авторське право (c) 2022 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА https://creativecommons.org/licenses/by-nc-nd/4.0 |