ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ

The idea of distributed active filtration is to compensate for the currents of higher harmonics and undesirable components of the power of the main network with inverters of renewable energy converters of the connected microgrid, which have reserves of apparent power. For the convenience of distribu...

Full description

Saved in:
Bibliographic Details
Date:2022
Main Authors: Артеменко, М.Ю., Чопик, В.В., Михальський, В.М., Шаповал, І.А., Поліщук, С.Й.
Format: Article
Language:English
Published: Інститут електродинаміки НАН України, Київ 2022
Subjects:
Online Access:https://techned.org.ua/index.php/techned/article/view/381
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Technical Electrodynamics

Institution

Technical Electrodynamics
id oai:ojs2.ted.new-point.com.ua:article-381
record_format ojs
institution Technical Electrodynamics
baseUrl_str
datestamp_date 2022-03-21T19:39:03Z
collection OJS
language English
topic потужність небалансу
мікромережа
стратегія керування паралельним активним фільтром
розподілена фільтрація
spellingShingle потужність небалансу
мікромережа
стратегія керування паралельним активним фільтром
розподілена фільтрація
Артеменко, М.Ю.
Чопик, В.В.
Михальський, В.М.
Шаповал, І.А.
Поліщук, С.Й.
ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ
topic_facet imbalance power
microgrid
shunt active filter control strategy
distributed filtering
потужність небалансу
мікромережа
стратегія керування паралельним активним фільтром
розподілена фільтрація
format Article
author Артеменко, М.Ю.
Чопик, В.В.
Михальський, В.М.
Шаповал, І.А.
Поліщук, С.Й.
author_facet Артеменко, М.Ю.
Чопик, В.В.
Михальський, В.М.
Шаповал, І.А.
Поліщук, С.Й.
author_sort Артеменко, М.Ю.
title ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ
title_short ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ
title_full ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ
title_fullStr ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ
title_full_unstemmed ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ
title_sort ідентифікація потужності небалансу трифазної чотирипровідної системи живлення для потреб її розподіленої компенсації
title_alt THE UNBALANCE POWER IDENTIFICATION IN THE THREE-PHASE FOUR-WIRE POWER SUPPLY SYSTEM FOR THE NEEDS OF ITS DISTRIBUTED COMPENSATION
description The idea of distributed active filtration is to compensate for the currents of higher harmonics and undesirable components of the power of the main network with inverters of renewable energy converters of the connected microgrid, which have reserves of apparent power. For the convenience of distributed compensation, it is proposed to identify the sinusoidal mode of the three-phase four-wire power system, provided that the symmetric source is six mutually orthogonal components of the three-coordinate vector of line currents. The power of imbalance is shown to be due to four mutually orthogonal components of the three-coordinate vector of line currents with defined reference voltage vectors, each of which is proportional to a separate orthogonal component of the power of imbalance. Integral formulas for determining the scalar values of the four specified orthogonal components of imbalance powers have been obtained, which open the possibility of accounting for their contribution to the deterioration of the quality of electrical energy and the synthesis of control signals for active distributed filtration. The connection between the four specified orthogonal components of the power of imbalance and the parameters of the linear unbalanced load was established, which made it possible to verify these integral formulas using a computer experiment. It is analytically established and experimentally confirmed that the squares of the two orthogonal components of the imbalance powers associated with the current of the neutral wire are included in the decomposition of the square of apparent power and power losses with the multiplier, depending on the ratio of the resistances of the transmission line of the three-phase four-wire power system. References 17, figures 3.
publisher Інститут електродинаміки НАН України, Київ
publishDate 2022
url https://techned.org.ua/index.php/techned/article/view/381
work_keys_str_mv AT artemenkomû theunbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation
AT čopikvv theunbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation
AT mihalʹsʹkijvm theunbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation
AT šapovalía theunbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation
AT políŝuksj theunbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation
AT artemenkomû ídentifíkacíâpotužnostínebalansutrifaznoíčotiriprovídnoísistemiživlennâdlâpotrebíírozpodílenoíkompensacíí
AT čopikvv ídentifíkacíâpotužnostínebalansutrifaznoíčotiriprovídnoísistemiživlennâdlâpotrebíírozpodílenoíkompensacíí
AT mihalʹsʹkijvm ídentifíkacíâpotužnostínebalansutrifaznoíčotiriprovídnoísistemiživlennâdlâpotrebíírozpodílenoíkompensacíí
AT šapovalía ídentifíkacíâpotužnostínebalansutrifaznoíčotiriprovídnoísistemiživlennâdlâpotrebíírozpodílenoíkompensacíí
AT políŝuksj ídentifíkacíâpotužnostínebalansutrifaznoíčotiriprovídnoísistemiživlennâdlâpotrebíírozpodílenoíkompensacíí
AT artemenkomû unbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation
AT čopikvv unbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation
AT mihalʹsʹkijvm unbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation
AT šapovalía unbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation
AT políŝuksj unbalancepoweridentificationinthethreephasefourwirepowersupplysystemfortheneedsofitsdistributedcompensation
first_indexed 2025-09-24T17:38:02Z
last_indexed 2025-09-24T17:38:02Z
_version_ 1844167817573695488
spelling oai:ojs2.ted.new-point.com.ua:article-3812022-03-21T19:39:03Z THE UNBALANCE POWER IDENTIFICATION IN THE THREE-PHASE FOUR-WIRE POWER SUPPLY SYSTEM FOR THE NEEDS OF ITS DISTRIBUTED COMPENSATION ІДЕНТИФІКАЦІЯ ПОТУЖНОСТІ НЕБАЛАНСУ ТРИФАЗНОЇ ЧОТИРИПРОВІДНОЇ СИСТЕМИ ЖИВЛЕННЯ ДЛЯ ПОТРЕБ ЇЇ РОЗПОДІЛЕНОЇ КОМПЕНСАЦІЇ Артеменко, М.Ю. Чопик, В.В. Михальський, В.М. Шаповал, І.А. Поліщук, С.Й. imbalance power microgrid shunt active filter control strategy distributed filtering потужність небалансу мікромережа стратегія керування паралельним активним фільтром розподілена фільтрація The idea of distributed active filtration is to compensate for the currents of higher harmonics and undesirable components of the power of the main network with inverters of renewable energy converters of the connected microgrid, which have reserves of apparent power. For the convenience of distributed compensation, it is proposed to identify the sinusoidal mode of the three-phase four-wire power system, provided that the symmetric source is six mutually orthogonal components of the three-coordinate vector of line currents. The power of imbalance is shown to be due to four mutually orthogonal components of the three-coordinate vector of line currents with defined reference voltage vectors, each of which is proportional to a separate orthogonal component of the power of imbalance. Integral formulas for determining the scalar values of the four specified orthogonal components of imbalance powers have been obtained, which open the possibility of accounting for their contribution to the deterioration of the quality of electrical energy and the synthesis of control signals for active distributed filtration. The connection between the four specified orthogonal components of the power of imbalance and the parameters of the linear unbalanced load was established, which made it possible to verify these integral formulas using a computer experiment. It is analytically established and experimentally confirmed that the squares of the two orthogonal components of the imbalance powers associated with the current of the neutral wire are included in the decomposition of the square of apparent power and power losses with the multiplier, depending on the ratio of the resistances of the transmission line of the three-phase four-wire power system. References 17, figures 3. Ідея розподіленої активної фільтрації полягає в компенсації струмів вищих гармонік та небажаних складових потужності основної мережі інверторами перетворювачів відновлюваної енергії приєднаної мікромережі, що мають резерви повної потужності. Для зручності розподіленої компенсації запропоновано ідентифікувати синусоїдний режим трифазної чотирипровідної системи живлення за умови симетричного джерела шістьма взаємно ортогональними складовими трикоординатного вектора лінійних струмів. Показано, що потужність небалансу зумовлена чотирма взаємно ортогональними складовими трикоординатного вектора лінійних струмів з визначеними опорними векторами напруг, кожен з яких пропорційний окремій ортогональній складовій потужності небалансу. Отримано інтегральні формули для визначення скалярних значень чотирьох зазначених ортогональних складових потужностей небалансу, що відкривають можливість обліку їх внеску у погіршення якості електричної енергії та синтезу керуючих сигналів для активної розподіленої фільтрації. Встановлено зв’язок між чотирма зазначеними ортогональними складовими потужності небалансу та параметрами лінійного незбалансованого навантаження, що дозволило верифікувати ці інтегральні формули за допомогою комп’ютерного експерименту. Аналітично встановлено та експериментально підтверджено, що квадрати двох ортогональних складових потужностей небалансу, пов’язані зі струмом нейтрального проводу, входять в декомпозиції квадрату повної потужності та потужності втрат із множником, що залежить від співвідношення опорів лінії передачі трифазної чотирипровідної системи живлення. Бібл. 17, рис. 3. Інститут електродинаміки НАН України, Київ 2022-03-19 Article Article application/pdf https://techned.org.ua/index.php/techned/article/view/381 10.15407/techned2022.02.012 Tekhnichna Elektrodynamika; No. 2 (2022): TEKHNICHNA ELEKTRODYNAMIKA; 012 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; № 2 (2022): ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; 012 2218-1903 1607-7970 10.15407/techned2022.02 en https://techned.org.ua/index.php/techned/article/view/381/306 Авторське право (c) 2022 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА https://creativecommons.org/licenses/by-nc-nd/4.0