ПІДВИЩЕННЯ ЕФЕКТИВНОСТІ ВИКОРИСТАННЯ СЕКЦІОНОВАНИХ АВТОТРАНСФОРМАТОРІВ З КОМУТАТОРОМ НА ВИХОДІ У СКЛАДІ СТАБІЛІЗАТОРА НАПРУГИ ЗМІННОГО СТРУМУ
In order to increase the efficiency of use of the autotransformer (AT) with tapped winding as a component of the transformer-and-switches executive structures (TSES) of AC voltage stabilizers, multiphysics simulation of the AT with the semiconductor commutator at the output has been fulfilled. The T...
Saved in:
| Date: | 2016 |
|---|---|
| Main Authors: | , |
| Format: | Article |
| Language: | Ukrainian |
| Published: |
Інститут електродинаміки НАН України, Київ
2016
|
| Subjects: | |
| Online Access: | https://techned.org.ua/index.php/techned/article/view/863 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Technical Electrodynamics |
Institution
Technical Electrodynamics| Summary: | In order to increase the efficiency of use of the autotransformer (AT) with tapped winding as a component of the transformer-and-switches executive structures (TSES) of AC voltage stabilizers, multiphysics simulation of the AT with the semiconductor commutator at the output has been fulfilled. The TSES, in which the commutator is placed at the input of the AT, has been compared with the proposed one. The advantage of the proposed TSES for certain parameters have been proven. The possibility of influence of purposeful change of positioning of the winding sections has been tracked. References 15, tables 3, figures 5. |
|---|