ПОБУДОВА, МЕТОДИ І ТЕХНІКА ДОСЛІДЖЕНЬ ВЛАСТИВОСТЕЙ ЕЛЕКТРОІЗОЛЯЦІЇ ПРИ НАДВИСОКИХ ТЕМПЕРАТУРАХ

This paper features the construction, operation and research on high-temperature electrical insulation at working temperatures up to 2000 0C. Investigations were carried out on the existing MH- generator using a specifically developed insulation module and device for continuous measurement and recor...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2013
Hauptverfasser: Фальковський, М.І., Примак, О.В.
Format: Artikel
Sprache:Ukrainisch
Veröffentlicht: Інститут електродинаміки НАН України, Київ 2013
Schlagworte:
Online Zugang:https://techned.org.ua/index.php/techned/article/view/998
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Technical Electrodynamics

Institution

Technical Electrodynamics
_version_ 1856544005215485952
author Фальковський, М.І.
Примак, О.В.
author_facet Фальковський, М.І.
Примак, О.В.
author_sort Фальковський, М.І.
baseUrl_str
collection OJS
datestamp_date 2023-01-04T14:44:23Z
description This paper features the construction, operation and research on high-temperature electrical insulation at working temperatures up to 2000 0C. Investigations were carried out on the existing MH- generator using a specifically developed insulation module and device for continuous measurement and recording of the resistance and dielectric strength of the insulation under AC current. The studies were conducted using an alternating current in order to reduce the influence of high temperature dielectric polarization on the measurements. The resistance value of the electrical insulation of the electrodes relative to the grounded housing of the MGDG channel and interelectrode insulation resistance pattern during changing operating regimes of MGDG were investigated in the area of the flow of the combustion products at temperatures up to 3000 0C. It was established that the resistance of the interelectrode insulation is determined by its surface resistance. The magnitude of the surface resistance depends on the type of the gas atmosphere in the channel such that the oxidative environment increases the surface resistance and reducing environment decreases it. Under the same temperature conditions the range of changes in the resistance of the interelectrode insulation in the channel was 3–4 orders of magnitude lower than the resistivity of the dielectric (MgO) in pure oxidizing atmosphere of the research apparatus. At temperatures above ~1300 0C surface resistance is increasingly determined by the properties of the dielectric. References 12, figures 6.
first_indexed 2025-09-24T17:39:14Z
format Article
id oai:ojs2.ted.new-point.com.ua:article-998
institution Technical Electrodynamics
language Ukrainian
last_indexed 2025-09-24T17:39:14Z
publishDate 2013
publisher Інститут електродинаміки НАН України, Київ
record_format ojs
spelling oai:ojs2.ted.new-point.com.ua:article-9982023-01-04T14:44:23Z CONSTRUCTION, TECHNOLOGY AND RESEARCH METHODS IN ULTRAHIGH TEMPERATURE ELECTRICAL INSULATION ПОБУДОВА, МЕТОДИ І ТЕХНІКА ДОСЛІДЖЕНЬ ВЛАСТИВОСТЕЙ ЕЛЕКТРОІЗОЛЯЦІЇ ПРИ НАДВИСОКИХ ТЕМПЕРАТУРАХ Фальковський, М.І. Примак, О.В. electrical insulation high temperature MHD generator електрична ізоляція високі температури МГД генератор This paper features the construction, operation and research on high-temperature electrical insulation at working temperatures up to 2000 0C. Investigations were carried out on the existing MH- generator using a specifically developed insulation module and device for continuous measurement and recording of the resistance and dielectric strength of the insulation under AC current. The studies were conducted using an alternating current in order to reduce the influence of high temperature dielectric polarization on the measurements. The resistance value of the electrical insulation of the electrodes relative to the grounded housing of the MGDG channel and interelectrode insulation resistance pattern during changing operating regimes of MGDG were investigated in the area of the flow of the combustion products at temperatures up to 3000 0C. It was established that the resistance of the interelectrode insulation is determined by its surface resistance. The magnitude of the surface resistance depends on the type of the gas atmosphere in the channel such that the oxidative environment increases the surface resistance and reducing environment decreases it. Under the same temperature conditions the range of changes in the resistance of the interelectrode insulation in the channel was 3–4 orders of magnitude lower than the resistivity of the dielectric (MgO) in pure oxidizing atmosphere of the research apparatus. At temperatures above ~1300 0C surface resistance is increasingly determined by the properties of the dielectric. References 12, figures 6. Розглянуто особливості побудови, роботи та досліджень одного з видів високотемпературної електричної ізоляції з робочою температурою до 2000 0С. Дослідження проведено на діючому МГД генераторі та за допомогою спеціально розроблених модельного вузла ізоляції і пристрою для безперервного вимірювання та запису опорів і електричної міцності ізоляції. Досліджено величини опору електричної ізоляції електродів відносно заземленого корпусу каналу та опору міжелектродної ізоляції в процесі зміни режимів роботи МГДГ. Встановлено, що опір міжелектродної ізоляції визначається її поверхневим опором. Його величина залежить від виду газової атмосфери в каналі: окислююча підвищує поверхневий опір, відновлююча його знижує. При температурах, вищих за ~ 1300 0С, поверхневий опір починає більше визначатися властивостями матеріалу діелектрика. Бібл. 12, рис. 6. Інститут електродинаміки НАН України, Київ 2013-12-26 Article Article application/pdf https://techned.org.ua/index.php/techned/article/view/998 Tekhnichna Elektrodynamika; No. 1 (2014): TEKHNICHNA ELEKTRODYNAMIKA; 088 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; № 1 (2014): ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; 088 2218-1903 1607-7970 uk https://techned.org.ua/index.php/techned/article/view/998/877 Авторське право (c) 2023 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА https://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle електрична ізоляція
високі температури
МГД генератор
Фальковський, М.І.
Примак, О.В.
ПОБУДОВА, МЕТОДИ І ТЕХНІКА ДОСЛІДЖЕНЬ ВЛАСТИВОСТЕЙ ЕЛЕКТРОІЗОЛЯЦІЇ ПРИ НАДВИСОКИХ ТЕМПЕРАТУРАХ
title ПОБУДОВА, МЕТОДИ І ТЕХНІКА ДОСЛІДЖЕНЬ ВЛАСТИВОСТЕЙ ЕЛЕКТРОІЗОЛЯЦІЇ ПРИ НАДВИСОКИХ ТЕМПЕРАТУРАХ
title_alt CONSTRUCTION, TECHNOLOGY AND RESEARCH METHODS IN ULTRAHIGH TEMPERATURE ELECTRICAL INSULATION
title_full ПОБУДОВА, МЕТОДИ І ТЕХНІКА ДОСЛІДЖЕНЬ ВЛАСТИВОСТЕЙ ЕЛЕКТРОІЗОЛЯЦІЇ ПРИ НАДВИСОКИХ ТЕМПЕРАТУРАХ
title_fullStr ПОБУДОВА, МЕТОДИ І ТЕХНІКА ДОСЛІДЖЕНЬ ВЛАСТИВОСТЕЙ ЕЛЕКТРОІЗОЛЯЦІЇ ПРИ НАДВИСОКИХ ТЕМПЕРАТУРАХ
title_full_unstemmed ПОБУДОВА, МЕТОДИ І ТЕХНІКА ДОСЛІДЖЕНЬ ВЛАСТИВОСТЕЙ ЕЛЕКТРОІЗОЛЯЦІЇ ПРИ НАДВИСОКИХ ТЕМПЕРАТУРАХ
title_short ПОБУДОВА, МЕТОДИ І ТЕХНІКА ДОСЛІДЖЕНЬ ВЛАСТИВОСТЕЙ ЕЛЕКТРОІЗОЛЯЦІЇ ПРИ НАДВИСОКИХ ТЕМПЕРАТУРАХ
title_sort побудова, методи і техніка досліджень властивостей електроізоляції при надвисоких температурах
topic електрична ізоляція
високі температури
МГД генератор
topic_facet electrical insulation
high temperature
MHD generator
електрична ізоляція
високі температури
МГД генератор
url https://techned.org.ua/index.php/techned/article/view/998
work_keys_str_mv AT falʹkovsʹkijmí constructiontechnologyandresearchmethodsinultrahightemperatureelectricalinsulation
AT primakov constructiontechnologyandresearchmethodsinultrahightemperatureelectricalinsulation
AT falʹkovsʹkijmí pobudovametodiítehníkadoslídženʹvlastivostejelektroízolâcííprinadvisokihtemperaturah
AT primakov pobudovametodiítehníkadoslídženʹvlastivostejelektroízolâcííprinadvisokihtemperaturah