Особливості модернізації частотоміра UA Ч3-101
JSC «Meridian» n. a. S. P. Korolyov at one point developed and mass-produced a wide-range microwave frequency meter of the 8-mm wavelength range UA Ч3-101. Over time, however, the device has become obsolete for a number of reasons, and the question arose of the need to replace it. Since the cost of...
Gespeichert in:
| Datum: | 2020 |
|---|---|
| Hauptverfasser: | , , , , |
| Format: | Artikel |
| Sprache: | Ukrainian |
| Veröffentlicht: |
PE "Politekhperiodika", Book and Journal Publishers
2020
|
| Schlagworte: | |
| Online Zugang: | https://www.tkea.com.ua/index.php/journal/article/view/TKEA2020.1-2.03 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Technology and design in electronic equipment |
Institution
Technology and design in electronic equipment| id |
oai:tkea.com.ua:article-107 |
|---|---|
| record_format |
ojs |
| institution |
Technology and design in electronic equipment |
| baseUrl_str |
|
| datestamp_date |
2025-08-02T16:36:33Z |
| collection |
OJS |
| language |
Ukrainian |
| topic |
частотомір перетворювач частоти модернізація міліметровий діапазон довжини хвилі |
| spellingShingle |
частотомір перетворювач частоти модернізація міліметровий діапазон довжини хвилі Krival’, I. I. Skripnyuk, A. I. Rudkovskiy, A. V. Protsenko, V. A. Prisyazhnyuk, O. A. Особливості модернізації частотоміра UA Ч3-101 |
| topic_facet |
frequency meter frequency converter modernization millimeter wavelength range частотомір перетворювач частоти модернізація міліметровий діапазон довжини хвилі |
| format |
Article |
| author |
Krival’, I. I. Skripnyuk, A. I. Rudkovskiy, A. V. Protsenko, V. A. Prisyazhnyuk, O. A. |
| author_facet |
Krival’, I. I. Skripnyuk, A. I. Rudkovskiy, A. V. Protsenko, V. A. Prisyazhnyuk, O. A. |
| author_sort |
Krival’, I. I. |
| title |
Особливості модернізації частотоміра UA Ч3-101 |
| title_short |
Особливості модернізації частотоміра UA Ч3-101 |
| title_full |
Особливості модернізації частотоміра UA Ч3-101 |
| title_fullStr |
Особливості модернізації частотоміра UA Ч3-101 |
| title_full_unstemmed |
Особливості модернізації частотоміра UA Ч3-101 |
| title_sort |
особливості модернізації частотоміра ua ч3-101 |
| title_alt |
Aspects of modernization of UA Ч3-101 frequency meter |
| description |
JSC «Meridian» n. a. S. P. Korolyov at one point developed and mass-produced a wide-range microwave frequency meter of the 8-mm wavelength range UA Ч3-101. Over time, however, the device has become obsolete for a number of reasons, and the question arose of the need to replace it. Since the cost of foreign models of frequency meters with similar parameters available on the market is quite high, the enterprise’s capabilities in solving this issue were considered. The analysis showed that the development of a new similar frequency meter will also be quite expensive, but the modernization of the existing one might be much cheaper, since the enterprise has all the infrastructure for serial production of the upgraded frequency meter.This article describes technical solutions for the replacement of labor-consuming microwave components of the UA Ч3-101 frequency meter, such as microstrip and waveguide input microwave converters, as well as optimization of the frequency measuring process of the input signal, which allowed us to upgrade the device according to the requirements.The use of the developed broadband small-sized frequency converter in the modernized UA Ч3-101A frequency meter made it possible to simplify the circuit and the frequency measurement process as much as possible, to use only one input microwave converter, to significantly reduce the weight and size of the device, to abandon the labor-consuming and expensive waveguide components of the device, and to double the sensitivity upgraded frequency meter.The proposed technical solution allowed simplifying the production process of the frequency meter, making the device more convenient to use. In addition, due to the optimization of circuit and design solutions in the upgraded frequency meter, it was possible to combine the counter and the gate driver on the same board, combine the reference frequency block with a 100 MHz tunable generator, abandon the switch, which allowed reducing power consumption and increasing the reliability of the device. |
| publisher |
PE "Politekhperiodika", Book and Journal Publishers |
| publishDate |
2020 |
| url |
https://www.tkea.com.ua/index.php/journal/article/view/TKEA2020.1-2.03 |
| work_keys_str_mv |
AT krivalii aspectsofmodernizationofuač3101frequencymeter AT skripnyukai aspectsofmodernizationofuač3101frequencymeter AT rudkovskiyav aspectsofmodernizationofuač3101frequencymeter AT protsenkova aspectsofmodernizationofuač3101frequencymeter AT prisyazhnyukoa aspectsofmodernizationofuač3101frequencymeter AT krivalii osoblivostímodernízacííčastotomírauač3101 AT skripnyukai osoblivostímodernízacííčastotomírauač3101 AT rudkovskiyav osoblivostímodernízacííčastotomírauač3101 AT protsenkova osoblivostímodernízacííčastotomírauač3101 AT prisyazhnyukoa osoblivostímodernízacííčastotomírauač3101 |
| first_indexed |
2025-09-24T17:30:13Z |
| last_indexed |
2025-09-24T17:30:13Z |
| _version_ |
1850410195649298432 |
| spelling |
oai:tkea.com.ua:article-1072025-08-02T16:36:33Z Aspects of modernization of UA Ч3-101 frequency meter Особливості модернізації частотоміра UA Ч3-101 Krival’, I. I. Skripnyuk, A. I. Rudkovskiy, A. V. Protsenko, V. A. Prisyazhnyuk, O. A. frequency meter frequency converter modernization millimeter wavelength range частотомір перетворювач частоти модернізація міліметровий діапазон довжини хвилі JSC «Meridian» n. a. S. P. Korolyov at one point developed and mass-produced a wide-range microwave frequency meter of the 8-mm wavelength range UA Ч3-101. Over time, however, the device has become obsolete for a number of reasons, and the question arose of the need to replace it. Since the cost of foreign models of frequency meters with similar parameters available on the market is quite high, the enterprise’s capabilities in solving this issue were considered. The analysis showed that the development of a new similar frequency meter will also be quite expensive, but the modernization of the existing one might be much cheaper, since the enterprise has all the infrastructure for serial production of the upgraded frequency meter.This article describes technical solutions for the replacement of labor-consuming microwave components of the UA Ч3-101 frequency meter, such as microstrip and waveguide input microwave converters, as well as optimization of the frequency measuring process of the input signal, which allowed us to upgrade the device according to the requirements.The use of the developed broadband small-sized frequency converter in the modernized UA Ч3-101A frequency meter made it possible to simplify the circuit and the frequency measurement process as much as possible, to use only one input microwave converter, to significantly reduce the weight and size of the device, to abandon the labor-consuming and expensive waveguide components of the device, and to double the sensitivity upgraded frequency meter.The proposed technical solution allowed simplifying the production process of the frequency meter, making the device more convenient to use. In addition, due to the optimization of circuit and design solutions in the upgraded frequency meter, it was possible to combine the counter and the gate driver on the same board, combine the reference frequency block with a 100 MHz tunable generator, abandon the switch, which allowed reducing power consumption and increasing the reliability of the device. Свого часу в ВАТ «Меридіан» ім. С. П. Корольова був розроблений і серійно випускався широкодіапазонний НВЧ-частотомір 8-міліметрового діапазону довжини хвилі UA Ч3-101. Однак з часом прилад з ряду причин морально застарів, і постало питання необхідності його заміни. Оскільки вартість наявних на ринку зарубіжних моделей частотомірів з аналогічними параметрами є досить великою, були розглянуті можливості підприємства у вирішенні цього питання. Аналіз показав, що розробка нового аналогічного частотоміру також обійдеться досить дорого, а ось модернізація наявного — набагато дешевше, оскільки на підприємстві є вся інфраструктура для серійного випуску модернізованого частотоміра.У статті описані технічні рішення по заміні трудомістких НВЧ-вузлів частотоміра UA Ч3-101, як от вхідні НВЧ-перетворювачі в мікросмужкових і хвилеводному виконанні, а також оптимізація алгоритму процесу вимірювання частоти вхідного сигналу, що дозволило провести модернізацію приладу відповідно до висунутих вимог.Використання в модернізованому частотомірі UA Ч3-101А розробленого широкосмугового малогабаритного перетворювача частоти дозволило максимально спростити схему та сам процес вимірювання частоти, використовувати тільки один вхідний НВЧ-перетворювач, значно зменшити масогабаритні показники приладу, відмовитися від трудомістких і дорогих хвилеводних вузлів приладу, в два рази збільшити чутливість модернізованого частотоміра.Запропоноване технічне рішення дозволило спростити процес виробництва частотоміра, зробити прилад більш зручним в експлуатації. Крім того, за рахунок оптимізації схемних і конструкторських рішень в модернізованому частотомірі вдалося поєднати на одній платі лічильник і формувач стробу, блок опорних частот поєднати з перестроюваним генератором 100 МГц, відмовитися від комутатора, що дозволило зменшити енергоспоживання і підвищити надійність приладу. PE "Politekhperiodika", Book and Journal Publishers 2020-04-28 Article Article Peer-reviewed Article application/pdf https://www.tkea.com.ua/index.php/journal/article/view/TKEA2020.1-2.03 10.15222/TKEA2020.1-2.03 Technology and design in electronic equipment; No. 1–2 (2020): Tekhnologiya i konstruirovanie v elektronnoi apparature; 3-7 Технологія та конструювання в електронній апаратурі; № 1–2 (2020): Технология и конструирование в электронной аппаратуре; 3-7 3083-6549 3083-6530 10.15222/TKEA2020.1-2 uk https://www.tkea.com.ua/index.php/journal/article/view/TKEA2020.1-2.03/97 Copyright (c) 2020 Krival’ I. I., Skripnyuk A. I., Rudkovskiy A. V., Protsenko V. A., Prisyazhnyuk O. A. http://creativecommons.org/licenses/by/4.0/ |