Исследование проволочного радиатора с тепловыми трубами для средств вычислительной техники
One approach to improving heat dissipation efficiency from computing components such as high-performance microprocessors is proposed. A prototype wire radiator was studied, consisting of copper wire with a diameter of 0.12 mm wound around a frame of two heat pipes, each 6 mm in diameter and 500 mm l...
Gespeichert in:
| Datum: | 2004 |
|---|---|
| Hauptverfasser: | , , |
| Format: | Artikel |
| Sprache: | Ukrainisch |
| Veröffentlicht: |
PE "Politekhperiodika", Book and Journal Publishers
2004
|
| Schlagworte: | |
| Online Zugang: | https://www.tkea.com.ua/index.php/journal/article/view/TKEA2004.6.29 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Technology and design in electronic equipment |
Institution
Technology and design in electronic equipment| Zusammenfassung: | One approach to improving heat dissipation efficiency from computing components such as high-performance microprocessors is proposed. A prototype wire radiator was studied, consisting of copper wire with a diameter of 0.12 mm wound around a frame of two heat pipes, each 6 mm in diameter and 500 mm long. It was shown that the temperature drop along the heat pipe is nearly 60 times smaller than that of a solid copper rod and 200 times smaller than that of a copper tube of the same dimensions. The use of wire finning allowed the average temperature in the heating zone to be reduced by an additional one-third at a heater power of 49.2 W. |
|---|