Исследование эффективности проволочного радиатора новой конструкции

The study investigates the heat transfer intensity of a wire radiator made of copper wire with a diameter of 0.12 mm under conditions of cooling a 2T808A transistor with a dissipated power of 5 W. With horizontal orientation of the radiator, the average heat transfer coefficient under natural air co...

Full description

Saved in:
Bibliographic Details
Date:2003
Main Authors: Kholvinskaya, L. M., Nikolaenko, T. Yu., Nikolaenko, Yu. E.
Format: Article
Language:Ukrainian
Published: PE "Politekhperiodika", Book and Journal Publishers 2003
Subjects:
Online Access:https://www.tkea.com.ua/index.php/journal/article/view/TKEA2003.5.28
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:Technology and design in electronic equipment

Institution

Technology and design in electronic equipment
Description
Summary:The study investigates the heat transfer intensity of a wire radiator made of copper wire with a diameter of 0.12 mm under conditions of cooling a 2T808A transistor with a dissipated power of 5 W. With horizontal orientation of the radiator, the average heat transfer coefficient under natural air convection was 53.4 W/(m2·°С), and under forced convection it reached 368 W/(m2·°С). These values are 5.9 times higher than those of loop-wire finning made of copper wire with a diameter of 0.68 mm under natural convection, and 4.5 times higher under forced convection (for wire diameter 0.5 mm).