Система отвода теплоты от теплонагруженных элементов РЭА на основе пульсационной тепловой трубы
The article presents a newly-developed compact heat removal system (HRS) with water used for coolant, operable in any position in space. In conditions of forced convection at output power of 120 Wt (160 Wt input power) thermal resistance of the HRS is 0.1 K/Wt and the system provides the average tem...
Gespeichert in:
| Datum: | 2013 |
|---|---|
| Hauptverfasser: | , |
| Format: | Artikel |
| Sprache: | Ukrainian |
| Veröffentlicht: |
PE "Politekhperiodika", Book and Journal Publishers
2013
|
| Schlagworte: | |
| Online Zugang: | https://www.tkea.com.ua/index.php/journal/article/view/TKEA2013.1.19 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Technology and design in electronic equipment |
Institution
Technology and design in electronic equipment| Zusammenfassung: | The article presents a newly-developed compact heat removal system (HRS) with water used for coolant, operable in any position in space. In conditions of forced convection at output power of 120 Wt (160 Wt input power) thermal resistance of the HRS is 0.1 K/Wt and the system provides the average temperature of the cooled object over the range of 58 to 60°C. Heat transfer characteristics of the HRS can be improved, as there is potential for its modification. |
|---|