Режим работы двухкаскадного термоэлектрического охлаждающего устройства, обеспечивающий минимальную интенсивность отказов
The model of interrelation of reliability indicators and the basic significant parameters of the two-cascade thermoelectric cooling device (TED) with consecutive electric connection of cascades is considered. The relations are received allowing to estimate reliability indicators, namely failure rate...
Saved in:
| Date: | 2011 |
|---|---|
| Main Author: | |
| Format: | Article |
| Language: | Ukrainian |
| Published: |
PE "Politekhperiodika", Book and Journal Publishers
2011
|
| Subjects: | |
| Online Access: | https://www.tkea.com.ua/index.php/journal/article/view/TKEA2011.1-2.39 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Technology and design in electronic equipment |
Institution
Technology and design in electronic equipment| Summary: | The model of interrelation of reliability indicators and the basic significant parameters of the two-cascade thermoelectric cooling device (TED) with consecutive electric connection of cascades is considered. The relations are received allowing to estimate reliability indicators, namely failure rate at construction two-cascade ТED working in current mode, providing the minimum failure rate in a wide range of temperature drops taking into account thermal loading. Possibility of use of this mode when the prevailing requirement is maintenance of the minimum failure rate and the maximum probability of non-failure operation cascade TED is shown. |
|---|