Вплив змін температури оточення на ефективність та потужність енергетичних установок
The article considers the possibility of adaptation of the power industry to the changes of climatic factors. In recent years it has become clear that current abnormal climate changes are likely to gain a regular character, forming a long-term trend of both rising the average earth surface temperatu...
Gespeichert in:
| Datum: | 2013 |
|---|---|
| Hauptverfasser: | , , |
| Format: | Artikel |
| Sprache: | Ukrainian |
| Veröffentlicht: |
General Energy Institute of the National Academy of Sciences of Ukraine
2013
|
| Schlagworte: | |
| Online Zugang: | https://systemre.org/index.php/journal/article/view/498 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | System Research in Energy |
Institution
System Research in Energy| id |
oai:www.systemre.org:article-498 |
|---|---|
| record_format |
ojs |
| institution |
System Research in Energy |
| baseUrl_str |
|
| datestamp_date |
2023-07-06T12:42:50Z |
| collection |
OJS |
| language |
Ukrainian |
| topic |
кліматичні фактори енергетичні характеристики ККД температура паротурбінні установки конденсація пари. |
| spellingShingle |
кліматичні фактори енергетичні характеристики ККД температура паротурбінні установки конденсація пари. Dubovskoy S.V. Babin M.E. Kadenskiy N.Y. Вплив змін температури оточення на ефективність та потужність енергетичних установок |
| topic_facet |
climatic factors energy characteristics efficiency temperature steam turbine plants steam condensation. кліматичні фактори енергетичні характеристики ККД температура паротурбінні установки конденсація пари. |
| format |
Article |
| author |
Dubovskoy S.V. Babin M.E. Kadenskiy N.Y. |
| author_facet |
Dubovskoy S.V. Babin M.E. Kadenskiy N.Y. |
| author_sort |
Dubovskoy S.V. |
| title |
Вплив змін температури оточення на ефективність та потужність енергетичних установок |
| title_short |
Вплив змін температури оточення на ефективність та потужність енергетичних установок |
| title_full |
Вплив змін температури оточення на ефективність та потужність енергетичних установок |
| title_fullStr |
Вплив змін температури оточення на ефективність та потужність енергетичних установок |
| title_full_unstemmed |
Вплив змін температури оточення на ефективність та потужність енергетичних установок |
| title_sort |
вплив змін температури оточення на ефективність та потужність енергетичних установок |
| title_alt |
Influence of environment temperature changes upon the efficiency and capacity of power plants |
| description |
The article considers the possibility of adaptation of the power industry to the changes of climatic factors. In recent years it has become clear that current abnormal climate changes are likely to gain a regular character, forming a long-term trend of both rising the average earth surface temperature and the increase in frequency and amplitude of abnormal climatic phenomena, paying more and more considerable physical impact upon the power infrastructure. The changes can fluctuate significantly during the lifetime of power objects, lasting for decades.That’s why studies aimed at determining the level of vulnerability of the fuel and power complex towards climate changes become highly relevant. The studies aim at elaboration of measures for adaptation of the whole power industry and of its individual enterprises to the probable climate changes.Most part of the work is devoted to evaluation of the climate vulnerability of the closed cycle thermal power plants’ efficiency, i.e. the power steam turbines of TPP, CHP and NPP, included into the generating capacities of the United Power Systems (UPS) of Ukraine with water cooling system: both the forward flow ones, using natural river water and large reservoirs, and the reversible ones, using artificial cooling circulating water in cooling ponds, spray ponds and wet cooling towers.Methodological aspects of influence, exerted upon efficiency and capacity of power plants by ambient temperature changes, have been elaborated. Сalculation of changes in power and efficiency of TPP, CHP and NPP steam turbines with accordance to the cooling water temperature by power characteristics has been carried out. Numerical evaluation of temperature dependence of capacity and efficiency of typical TPP and NPP turbines was carried out.It was concluded, that due to a significant non-linearity of temperature change processes, appropriate values of temperature coefficients of efficiency in particular temperature zones should be available for their correct representation, such particular zones are picked out.Air temperature makes the most significant impact upon fossil fueled heating plants. The effect of air temperature increasing is taken into account in energy characteristics of water-heating boilers in the form of an amendment to the gross efficiency, provided for the most common in Ukraine PTVM-100 district heating boilers. |
| publisher |
General Energy Institute of the National Academy of Sciences of Ukraine |
| publishDate |
2013 |
| url |
https://systemre.org/index.php/journal/article/view/498 |
| work_keys_str_mv |
AT dubovskoysv influenceofenvironmenttemperaturechangesupontheefficiencyandcapacityofpowerplants AT babinme influenceofenvironmenttemperaturechangesupontheefficiencyandcapacityofpowerplants AT kadenskiyny influenceofenvironmenttemperaturechangesupontheefficiencyandcapacityofpowerplants AT dubovskoysv vplivzmíntemperaturiotočennânaefektivnístʹtapotužnístʹenergetičnihustanovok AT babinme vplivzmíntemperaturiotočennânaefektivnístʹtapotužnístʹenergetičnihustanovok AT kadenskiyny vplivzmíntemperaturiotočennânaefektivnístʹtapotužnístʹenergetičnihustanovok |
| first_indexed |
2025-09-24T17:33:33Z |
| last_indexed |
2025-09-24T17:33:33Z |
| _version_ |
1850410236400107520 |
| spelling |
oai:www.systemre.org:article-4982023-07-06T12:42:50Z Influence of environment temperature changes upon the efficiency and capacity of power plants Вплив змін температури оточення на ефективність та потужність енергетичних установок Dubovskoy S.V. Babin M.E. Kadenskiy N.Y. climatic factors, energy characteristics, efficiency, temperature, steam turbine plants, steam condensation. кліматичні фактори, енергетичні характеристики, ККД, температура, паротурбінні установки, конденсація пари. The article considers the possibility of adaptation of the power industry to the changes of climatic factors. In recent years it has become clear that current abnormal climate changes are likely to gain a regular character, forming a long-term trend of both rising the average earth surface temperature and the increase in frequency and amplitude of abnormal climatic phenomena, paying more and more considerable physical impact upon the power infrastructure. The changes can fluctuate significantly during the lifetime of power objects, lasting for decades.That’s why studies aimed at determining the level of vulnerability of the fuel and power complex towards climate changes become highly relevant. The studies aim at elaboration of measures for adaptation of the whole power industry and of its individual enterprises to the probable climate changes.Most part of the work is devoted to evaluation of the climate vulnerability of the closed cycle thermal power plants’ efficiency, i.e. the power steam turbines of TPP, CHP and NPP, included into the generating capacities of the United Power Systems (UPS) of Ukraine with water cooling system: both the forward flow ones, using natural river water and large reservoirs, and the reversible ones, using artificial cooling circulating water in cooling ponds, spray ponds and wet cooling towers.Methodological aspects of influence, exerted upon efficiency and capacity of power plants by ambient temperature changes, have been elaborated. Сalculation of changes in power and efficiency of TPP, CHP and NPP steam turbines with accordance to the cooling water temperature by power characteristics has been carried out. Numerical evaluation of temperature dependence of capacity and efficiency of typical TPP and NPP turbines was carried out.It was concluded, that due to a significant non-linearity of temperature change processes, appropriate values of temperature coefficients of efficiency in particular temperature zones should be available for their correct representation, such particular zones are picked out.Air temperature makes the most significant impact upon fossil fueled heating plants. The effect of air temperature increasing is taken into account in energy characteristics of water-heating boilers in the form of an amendment to the gross efficiency, provided for the most common in Ukraine PTVM-100 district heating boilers. У статті розглянуто можливість адаптації енергетичної галузі до змін кліматичних факторів.Останніми роками стає дедалі зрозумілим, що аномальні кліматичні зміни набувають закономірного характеру, формуючи багаторічний тренд як щодо підвищення середньої температури земної поверхні, так і щодо зростання частоти і амплітуди аномальних кліматичних проявів, що здійснюють дедалі більші фізичні впливи на енергетичну інфраструктуру. Вони можуть істотно змінюватися за час існування енергетичних об’єктів, що триває десятки років.Це зумовлює високу актуальність досліджень з визначення вразливості об’єктів паливно-енергетичного комплексу до змін клімату, спрямованих на розробки заходів з адаптації енергетичної галузі в цілому, а також її окремих підприємств до імовірних кліматичних змін.Основна частина роботи спрямована на оцінку кліматичної вразливості ККД теплових електричних станцій замкненого циклу, а саме, потужних паротурбінних установок ТЕС, ТЕЦ і АЕС, що входять до складу генеруючих потужностей Об’єднаної енергетичної системи (ОЕС) України, які мають водяні системи охолодження: прямотокові, що використовують природну воду рік і великих водоймищ і обернені, що здійснюють штучне охолодження циркуляційної води у ставках-охолоджувачах, бризкальних басейнах і мокрих градирнях.Розроблено методологічні аспекти впливу змін температури оточення на ефективність та потужність енергетичних установок. Виконано розрахунки з визначення змін потужності і ККД паротурбінних установок ТЕС, ТЕЦ та АЕС залежно від температури охолоджувальної води за енергетичними характеристиками. Проведено чисельні оцінки температурної залежності потужності та ККД типових турбоустановок ТЕС та АЕС.Зроблено висновки про те, що внаслідок суттєвої нелінійності процесів температурних змін, для їх коректного відображення необхідно надавати відповідні значення температурних коефіцієнтів ККД у окремих характерних температурних зонах і вибрано таки характерні зони.Найбільший вплив на ефективність роботи опалювальних котелень на органічному паливі здійснює температура атмосферного повітря. Ефект впливу збільшення температури повітря враховується в енергетичних характеристиках водогрійних котельних агрегатів у вигляді поправки на ККД брутто, яка надана для найбільш поширених в Україні котлів систем централізованого теплопостачання типу ПТВМ-100. General Energy Institute of the National Academy of Sciences of Ukraine 2013-11-12 Article Article application/pdf https://systemre.org/index.php/journal/article/view/498 System Research in Energy; No. 3 (34) (2013): The Problems of General Energy; 35-46 Системні дослідження в енергетиці; № 3 (34) (2013): Проблеми загальної енергетики; 35-46 2786-7102 2786-7633 uk https://systemre.org/index.php/journal/article/view/498/432 |