Універсальна модель регулювання частоти і потужності в об’єднаних енергосистемах

Elaboration of a general-purpose mathematical model with corresponding software and information complex (SIC), allowing study of the automatic frequency and power control (AFPC) systems, built on the basis of generator regulators, controllable loads and their combinations, had been proved to be a ne...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2013
Hauptverfasser: Kulyk М.M., Dryomin V.P.
Format: Artikel
Sprache:Ukrainian
Veröffentlicht: General Energy Institute of the National Academy of Sciences of Ukraine 2013
Schlagworte:
Online Zugang:https://systemre.org/index.php/journal/article/view/500
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:System Research in Energy

Institution

System Research in Energy
id oai:www.systemre.org:article-500
record_format ojs
institution System Research in Energy
baseUrl_str
datestamp_date 2023-07-06T12:42:16Z
collection OJS
language Ukrainian
topic модель
частота
потужність
точність
регулятор
енергосистема.
spellingShingle модель
частота
потужність
точність
регулятор
енергосистема.
Kulyk М.M.
Dryomin V.P.
Універсальна модель регулювання частоти і потужності в об’єднаних енергосистемах
topic_facet model
frequency
power
accuracy
regulator
power systems.
модель
частота
потужність
точність
регулятор
енергосистема.
format Article
author Kulyk М.M.
Dryomin V.P.
author_facet Kulyk М.M.
Dryomin V.P.
author_sort Kulyk М.M.
title Універсальна модель регулювання частоти і потужності в об’єднаних енергосистемах
title_short Універсальна модель регулювання частоти і потужності в об’єднаних енергосистемах
title_full Універсальна модель регулювання частоти і потужності в об’єднаних енергосистемах
title_fullStr Універсальна модель регулювання частоти і потужності в об’єднаних енергосистемах
title_full_unstemmed Універсальна модель регулювання частоти і потужності в об’єднаних енергосистемах
title_sort універсальна модель регулювання частоти і потужності в об’єднаних енергосистемах
title_alt General-puropse model of frequency and capacity regulation in united power systems
description Elaboration of a general-purpose mathematical model with corresponding software and information complex (SIC), allowing study of the automatic frequency and power control (AFPC) systems, built on the basis of generator regulators, controllable loads and their combinations, had been proved to be a necessity.The general-purpose model of frequency and power regulation in united power systems with the above mentioned facilities was elaborated and studied. The model is constructed on the basis of the most precise system character equations and the equations, describing the influence of systematic frequency and power changes upon the power system objects (generators, load, regulators). It allows for the non-linear constraints, that are inherent to regulators (operating speed, maximum power, the dead zone). The model was synthesized in the canonical form, allowing describing the power system as the aggregate one as well as detailing it to a specific generator and a specific load.The digital modeling, carried out by means of the specially elaborated SIC with due facilities, revealed the necessity of considering the above mentioned technological restrictions at the study of the automatic frequency and power control, as the ignorance of them leads to serious mistakes and even incorrect results, presented in the most part of existing publications.The digital modeling of the automatic frequency and power control systems’ processes in the systems with different regulators under conditions of the Ukrainian UPS proved the requirements as to operating speed to be met with confidence only by the HPP generators and the controllable loads at the water pump systems. The oil and gas units with the marginal productivity of up to 6%/min and all the coal-fired units require a multiple increase in backup capacity of the secondary regulation to meet the requirements of marginal extent of the regulatory process.The combined use of primary regulator generator regulators and high-speed controllable loads at heat pump equipment in the AFPC systems completely satisfy both national and international requirements as to such systems.
publisher General Energy Institute of the National Academy of Sciences of Ukraine
publishDate 2013
url https://systemre.org/index.php/journal/article/view/500
work_keys_str_mv AT kulykmm generalpuropsemodeloffrequencyandcapacityregulationinunitedpowersystems
AT dryominvp generalpuropsemodeloffrequencyandcapacityregulationinunitedpowersystems
AT kulykmm uníversalʹnamodelʹregulûvannâčastotiípotužnostívobêdnanihenergosistemah
AT dryominvp uníversalʹnamodelʹregulûvannâčastotiípotužnostívobêdnanihenergosistemah
first_indexed 2025-09-24T17:33:33Z
last_indexed 2025-09-24T17:33:33Z
_version_ 1850410236839460864
spelling oai:www.systemre.org:article-5002023-07-06T12:42:16Z General-puropse model of frequency and capacity regulation in united power systems Універсальна модель регулювання частоти і потужності в об’єднаних енергосистемах Kulyk М.M. Dryomin V.P. model, frequency, power, accuracy, regulator, power systems. модель, частота, потужність, точність, регулятор, енергосистема. Elaboration of a general-purpose mathematical model with corresponding software and information complex (SIC), allowing study of the automatic frequency and power control (AFPC) systems, built on the basis of generator regulators, controllable loads and their combinations, had been proved to be a necessity.The general-purpose model of frequency and power regulation in united power systems with the above mentioned facilities was elaborated and studied. The model is constructed on the basis of the most precise system character equations and the equations, describing the influence of systematic frequency and power changes upon the power system objects (generators, load, regulators). It allows for the non-linear constraints, that are inherent to regulators (operating speed, maximum power, the dead zone). The model was synthesized in the canonical form, allowing describing the power system as the aggregate one as well as detailing it to a specific generator and a specific load.The digital modeling, carried out by means of the specially elaborated SIC with due facilities, revealed the necessity of considering the above mentioned technological restrictions at the study of the automatic frequency and power control, as the ignorance of them leads to serious mistakes and even incorrect results, presented in the most part of existing publications.The digital modeling of the automatic frequency and power control systems’ processes in the systems with different regulators under conditions of the Ukrainian UPS proved the requirements as to operating speed to be met with confidence only by the HPP generators and the controllable loads at the water pump systems. The oil and gas units with the marginal productivity of up to 6%/min and all the coal-fired units require a multiple increase in backup capacity of the secondary regulation to meet the requirements of marginal extent of the regulatory process.The combined use of primary regulator generator regulators and high-speed controllable loads at heat pump equipment in the AFPC systems completely satisfy both national and international requirements as to such systems. Доведена необхідність у розробленні універсальної математичної моделі та відповідного програмно-інформаційного комплексу (ПІК), в яких була б забезпечена можливість дослідження систем АРЧП, побудованих на базі генераторів-регуляторів, споживачів-регуляторів та їх комбінацій.Розроблена та досліджена універсальна модель регулювання частоти і потужності в об’єднаних енергосистемах, в якій забезпечена така можливість. Модель побудована на основі найбільш точних рівнянь системного характеру та рівнянь, що описують вплив системних змін частоти і потужності на об’єкти енергосистеми (генератори, навантаження, регулятори). Вона враховує нелінійні обмеження, властиві регуляторам (швидкодія, максимальна потужність, зона нечутливості). Модель синтезована в канонічній формі, що дозволяє описувати енергосистему як в агрегованому вигляді, так і доводити її деталізацію аж до конкретного генератора та споживача.Проведене цифрове моделювання на розробленому ПІК із такими можливостями показало, що при дослідженні процесів АРЧП необхідно враховувати зазначені технологічні обмеження, оскільки їх ігнорування, як це робиться в більшості публікацій, призводить до грубих помилок і навіть до неправильних результатів.Цифрове моделювання процесів АРЧП в системах з різними регуляторами показало, що в умовах ОЕС України вимоги щодо їх швидкодії впевнено задовольняють лише генератори ГЕС та споживачі-регулятори на теплонасосних системах. Газомазутні блоки з граничною швидкодією до 6%/хв та всі пиловугільні блоки для забезпечення вимог щодо граничної протяжності процесу регулювання потребують кратного збільшення резервної потужності вторинного регулювання.Комбіноване використання у складі системи АРЧП генераторів-регуляторів первинного регулювання та швидкодіючих споживачів-регуляторів на теплонасосному устаткуванні цілком задовольняють як національні, так і міжнародні вимоги до таких систем. General Energy Institute of the National Academy of Sciences of Ukraine 2013-12-19 Article Article application/pdf https://systemre.org/index.php/journal/article/view/500 System Research in Energy; No. 4 (35) (2013): The Problems of General Energy; 5-15 Системні дослідження в енергетиці; № 4 (35) (2013): Проблеми загальної енергетики; 5-15 2786-7102 2786-7633 uk https://systemre.org/index.php/journal/article/view/500/434