Потенціал акумуляції теплової енергії в мережах
When using the electrothermal consumers-controllers (ETCC) in distric heating (DH) systems for frequency control, and for active power it is important to know their power during the heating and non-heating seasons and dependency of such power on the ambient temperature. Currently these issues are no...
Збережено в:
| Дата: | 2014 |
|---|---|
| Автор: | |
| Формат: | Стаття |
| Мова: | Ukrainian |
| Опубліковано: |
General Energy Institute of the National Academy of Sciences of Ukraine
2014
|
| Теми: | |
| Онлайн доступ: | https://systemre.org/index.php/journal/article/view/535 |
| Теги: |
Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
|
| Назва журналу: | System Research in Energy |
Репозитарії
System Research in Energy| id |
oai:www.systemre.org:article-535 |
|---|---|
| record_format |
ojs |
| institution |
System Research in Energy |
| baseUrl_str |
|
| datestamp_date |
2023-07-06T12:40:22Z |
| collection |
OJS |
| language |
Ukrainian |
| topic |
теплові мережі акумуляція теплове навантаження температурний графік теплова потужність витрати теплоносія температура теплоносія потенціал. |
| spellingShingle |
теплові мережі акумуляція теплове навантаження температурний графік теплова потужність витрати теплоносія температура теплоносія потенціал. Derii V.O. Потенціал акумуляції теплової енергії в мережах |
| topic_facet |
heating networks accumulation heat load temperature chart heating power heat carrier consumption heat carrier temperature potential. теплові мережі акумуляція теплове навантаження температурний графік теплова потужність витрати теплоносія температура теплоносія потенціал. |
| format |
Article |
| author |
Derii V.O. |
| author_facet |
Derii V.O. |
| author_sort |
Derii V.O. |
| title |
Потенціал акумуляції теплової енергії в мережах |
| title_short |
Потенціал акумуляції теплової енергії в мережах |
| title_full |
Потенціал акумуляції теплової енергії в мережах |
| title_fullStr |
Потенціал акумуляції теплової енергії в мережах |
| title_full_unstemmed |
Потенціал акумуляції теплової енергії в мережах |
| title_sort |
потенціал акумуляції теплової енергії в мережах |
| title_alt |
Potential of thermal energy accumulation in distric heating systems networks |
| description |
When using the electrothermal consumers-controllers (ETCC) in distric heating (DH) systems for frequency control, and for active power it is important to know their power during the heating and non-heating seasons and dependency of such power on the ambient temperature. Currently these issues are not studied completely that can be an obstacle to mass adoption of ETCC in DH systems.Total capacity of standard heat generators and ETCC transferred to the networks is distributed as follows: one part of it is designed to compensate the losses, the second part – to compensate heat load of consumers, and the third part causes the heat energy accumulation, which circulates in the networks.The conducted studies have shown that during the heating season the value of accumulated heat in the networks is directly proportional to the ambient air temperature. This dependency is expressed by a piecewise linear function. When ambient air temperature is smaller than calculated one, accumulation in heat networks is impossible. This can be explained by the fact that the parameters of the heat carrier reached the maximum permissible values for safety operation of the network, all energy in the network compensates the heat load and losses. When increasing ambient air temperature, the accumulation potential increases reaching a maximum value at the culminating point of the temperature chart.During non-heating season the only load of DH system is hot water. Heat carrier consumption is 2-3 times smaller than during the heating season. Heat energy accumulation time in the networks coincides with time of minimum hot water distribution. In order to be within the maximum heat carrier temperature in the return pipeline, heat energy can be accumulated at the expanse of increasing the heat carrier consumption at constant temperature in the supply pipeline. The value of accumulated heat energy will be much lower than during the heating season. |
| publisher |
General Energy Institute of the National Academy of Sciences of Ukraine |
| publishDate |
2014 |
| url |
https://systemre.org/index.php/journal/article/view/535 |
| work_keys_str_mv |
AT deriivo potentialofthermalenergyaccumulationindistricheatingsystemsnetworks AT deriivo potencíalakumulâcííteplovoíenergíívmerežah |
| first_indexed |
2025-09-24T17:33:37Z |
| last_indexed |
2025-09-24T17:33:37Z |
| _version_ |
1844167539132727296 |
| spelling |
oai:www.systemre.org:article-5352023-07-06T12:40:22Z Potential of thermal energy accumulation in distric heating systems networks Потенціал акумуляції теплової енергії в мережах Derii V.O. heating networks, accumulation, heat load, temperature chart, heating power, heat carrier consumption, heat carrier temperature, potential. теплові мережі, акумуляція, теплове навантаження, температурний графік, теплова потужність, витрати теплоносія, температура теплоносія, потенціал. When using the electrothermal consumers-controllers (ETCC) in distric heating (DH) systems for frequency control, and for active power it is important to know their power during the heating and non-heating seasons and dependency of such power on the ambient temperature. Currently these issues are not studied completely that can be an obstacle to mass adoption of ETCC in DH systems.Total capacity of standard heat generators and ETCC transferred to the networks is distributed as follows: one part of it is designed to compensate the losses, the second part – to compensate heat load of consumers, and the third part causes the heat energy accumulation, which circulates in the networks.The conducted studies have shown that during the heating season the value of accumulated heat in the networks is directly proportional to the ambient air temperature. This dependency is expressed by a piecewise linear function. When ambient air temperature is smaller than calculated one, accumulation in heat networks is impossible. This can be explained by the fact that the parameters of the heat carrier reached the maximum permissible values for safety operation of the network, all energy in the network compensates the heat load and losses. When increasing ambient air temperature, the accumulation potential increases reaching a maximum value at the culminating point of the temperature chart.During non-heating season the only load of DH system is hot water. Heat carrier consumption is 2-3 times smaller than during the heating season. Heat energy accumulation time in the networks coincides with time of minimum hot water distribution. In order to be within the maximum heat carrier temperature in the return pipeline, heat energy can be accumulated at the expanse of increasing the heat carrier consumption at constant temperature in the supply pipeline. The value of accumulated heat energy will be much lower than during the heating season. При використанні електротеплових споживачів-регуляторів (ЕТСР) в системах централізованого теплопостачання для регулювання частоти та активної потужності важливо знати, яка може бути їх потужність в опалювальний та міжопалювальний періоди та як ця потужність залежить від температури навколишнього повітря. На даний час ці питання недостатньо вивчені, що може бути перешкодою для масового впровадження ЕТСР в централізованих системах теплопостачання.Сумарна потужність штатних теплогенераторів та ЕТСР, яка підводиться до мереж, розподіляється таким чином: частина її іде на компенсацію втрат, частина на покриття теплового навантаження споживачів, а частина спричиняє акумуляцію теплової енергії, яка циркулює в мережах.Проведені дослідження показали, що в опалювальний період величина акумульованої теплової енергії в мережах прямо пропорційно залежить від температури навколишнього повітря. Ця залежність виражається кусочно-лінійною функцією. При температурах навколишнього повітря менших за розрахункову, акумуляція в теплових мережах неможлива. Цей факт пояснюється тим, що параметри теплоносія досягли максимально допустимих значень для безпечної роботи мережі і вся енергія в мережі іде на покриття теплового навантаження та компенсації втрат. Із збільшенням температури навколишнього повітря потенціал акумуляції зростає досягаючи максимуму в точці злому температурного графіка.В міжопалювальний період єдиним навантаженням системи теплопостачання є гаряча вода. Витрати теплоносія в 2–3 рази менші, ніж в опалювальний сезон. Час акумуляції теплової енергії в мережах збігається з часом мінімального водорозбору гарячої води. Щоб не перевищити максимальну температуру теплоносія у зворотному трубопроводі, акумулювати теплову енергію можливо за рахунок збільшення витрат теплоносія при незмінній його температурі у подавальному трубопроводі. Величина акумульованої теплової енергії буде значно меншою, ніж в опалювальний період. General Energy Institute of the National Academy of Sciences of Ukraine 2014-11-27 Article Article application/pdf https://systemre.org/index.php/journal/article/view/535 System Research in Energy; No. 4 (39) (2014): The Problems of General Energy; 29-33 Системні дослідження в енергетиці; № 4 (39) (2014): Проблеми загальної енергетики; 29-33 2786-7102 2786-7633 uk https://systemre.org/index.php/journal/article/view/535/471 |