Визначення максимально-допустимих потужностей сонячних електростанцій в ОЕС України

The maximum value of the solar power plant (SPP) in the power system depends on the performance reserve and regulating capacity of the automatic frequency and power control (AFPC) system. It is believed that the regulatory capacity of the system AFPC enough if AFPC is able to compensate for perturba...

Full description

Saved in:
Bibliographic Details
Date:2016
Main Author: Dryomin V.P.
Format: Article
Language:Ukrainian
Published: General Energy Institute of the National Academy of Sciences of Ukraine 2016
Subjects:
Online Access:https://systemre.org/index.php/journal/article/view/543
Tags: Add Tag
No Tags, Be the first to tag this record!
Journal Title:System Research in Energy

Institution

System Research in Energy
id oai:www.systemre.org:article-543
record_format ojs
institution System Research in Energy
baseUrl_str
datestamp_date 2023-09-12T12:40:46Z
collection OJS
language Ukrainian
topic математичне моделювання
сонячні електростанції
регулювання частоти
споживачі-регулятори
генератори-регулятори
АРЧП
об’єднана енергосистема.
spellingShingle математичне моделювання
сонячні електростанції
регулювання частоти
споживачі-регулятори
генератори-регулятори
АРЧП
об’єднана енергосистема.
Dryomin V.P.
Визначення максимально-допустимих потужностей сонячних електростанцій в ОЕС України
topic_facet mathematical modeling
automatic control
frequency control
solar power plant
generatorregulator
controllable load
automatic frequency and power control system
interconnected power system.
математичне моделювання
сонячні електростанції
регулювання частоти
споживачі-регулятори
генератори-регулятори
АРЧП
об’єднана енергосистема.
format Article
author Dryomin V.P.
author_facet Dryomin V.P.
author_sort Dryomin V.P.
title Визначення максимально-допустимих потужностей сонячних електростанцій в ОЕС України
title_short Визначення максимально-допустимих потужностей сонячних електростанцій в ОЕС України
title_full Визначення максимально-допустимих потужностей сонячних електростанцій в ОЕС України
title_fullStr Визначення максимально-допустимих потужностей сонячних електростанцій в ОЕС України
title_full_unstemmed Визначення максимально-допустимих потужностей сонячних електростанцій в ОЕС України
title_sort визначення максимально-допустимих потужностей сонячних електростанцій в оес україни
title_alt The determination of maximum capacities of solar power plants in IPS of Ukraine
description The maximum value of the solar power plant (SPP) in the power system depends on the performance reserve and regulating capacity of the automatic frequency and power control (AFPC) system. It is believed that the regulatory capacity of the system AFPC enough if AFPC is able to compensate for perturbations caused by the action of SPP. The frequency deviation in the power system should remain in the range of ±0.02 Hz (according to the requirements of ENTSO-E) or ±0.2 Hz (actual requirements for IPS of Ukraine).Given the approach (program of experiments, the algorithm of their conduct) to the determination of maximum capacities of SPP as a part of IPS of Ukraine. As a result of experiments obtained values of maximum capacity of SPP that the system AFPC is able to compensate under different initial conditions. Among them: the different types and composition of regulators (hydrounits of hydroelectric power plant, coal-fired thermal power plants, controllable loads); the permissible frequency deviation of 0.2 Hz or 0.02 Hz; the maximum power the various regulators, and SPP.As a result of research, including it is established that, for example, for a permissible frequency deviation of 0.2 Hz in IPS of Ukraine with AFPC based on the pulverized coal (PC) power station with a reserve of 1000 MW power limit SPP is 581 MW, whereas for compensation of SPP power of 1 GW need generators-regulators PC thermal power plant with the capacity of 9.3 GW. This variation is explained by the self-regulatory effect which is manifested at AFPC with PC thermal power plants due to low performance of this type of regulators. To compensate for a 1 GW SPP ceteris paribus will require 310 MW generators-regulators hydroelectric power plant of 300 MW or controllable load.
publisher General Energy Institute of the National Academy of Sciences of Ukraine
publishDate 2016
url https://systemre.org/index.php/journal/article/view/543
work_keys_str_mv AT dryominvp thedeterminationofmaximumcapacitiesofsolarpowerplantsinipsofukraine
AT dryominvp viznačennâmaksimalʹnodopustimihpotužnostejsonâčnihelektrostancíjvoesukraíni
AT dryominvp determinationofmaximumcapacitiesofsolarpowerplantsinipsofukraine
first_indexed 2025-09-24T17:33:38Z
last_indexed 2025-09-24T17:33:38Z
_version_ 1850410242841509888
spelling oai:www.systemre.org:article-5432023-09-12T12:40:46Z The determination of maximum capacities of solar power plants in IPS of Ukraine Визначення максимально-допустимих потужностей сонячних електростанцій в ОЕС України Dryomin V.P. mathematical modeling, automatic control, frequency control, solar power plant, generatorregulator, controllable load, automatic frequency and power control system, interconnected power system. математичне моделювання, сонячні електростанції, регулювання частоти, споживачі-регулятори, генератори-регулятори, АРЧП, об’єднана енергосистема. The maximum value of the solar power plant (SPP) in the power system depends on the performance reserve and regulating capacity of the automatic frequency and power control (AFPC) system. It is believed that the regulatory capacity of the system AFPC enough if AFPC is able to compensate for perturbations caused by the action of SPP. The frequency deviation in the power system should remain in the range of ±0.02 Hz (according to the requirements of ENTSO-E) or ±0.2 Hz (actual requirements for IPS of Ukraine).Given the approach (program of experiments, the algorithm of their conduct) to the determination of maximum capacities of SPP as a part of IPS of Ukraine. As a result of experiments obtained values of maximum capacity of SPP that the system AFPC is able to compensate under different initial conditions. Among them: the different types and composition of regulators (hydrounits of hydroelectric power plant, coal-fired thermal power plants, controllable loads); the permissible frequency deviation of 0.2 Hz or 0.02 Hz; the maximum power the various regulators, and SPP.As a result of research, including it is established that, for example, for a permissible frequency deviation of 0.2 Hz in IPS of Ukraine with AFPC based on the pulverized coal (PC) power station with a reserve of 1000 MW power limit SPP is 581 MW, whereas for compensation of SPP power of 1 GW need generators-regulators PC thermal power plant with the capacity of 9.3 GW. This variation is explained by the self-regulatory effect which is manifested at AFPC with PC thermal power plants due to low performance of this type of regulators. To compensate for a 1 GW SPP ceteris paribus will require 310 MW generators-regulators hydroelectric power plant of 300 MW or controllable load. Максимальне значення потужностей СЕС в енергосистемі залежить від величини резерву і швидкодії регулюючих потужностей системи автоматичного регулювання частоти і потужності (АРЧП). Вважається, що регулюючих потужностей системи АРЧП достатньо, якщо АРЧП здатна компенсувати збурення, викликане дією СЕС. При цьому відхилення частоти в енергосистемі має залишатися в діапазоні ±0,02 Гц (за вимогами ENTSO-E) або ±0,2 Гц (актуальні вимоги для ОЕС України).Наведено підхід (програма експериментів, алгоритм їх проведення) до визначення граничних потужностей СЕС, що входять до складу ОЕС України. В результаті проведених експериментів отримано значення максимальних потужностей СЕС, які система АРЧП в змозі компенсувати при різних початкових умовах. Серед них: різні типи і склад регуляторів (гідроагрегати ГЕС, пиловугільні ТЕС, споживачі-регулятори); допустиме відхилення частоти 0,2 Гц або 0,02 Гц; різні максимальні потужності регуляторів і СЕС.В результаті досліджень, у тому числі встановлено, що, наприклад, для допустимого відхилення частоти 0,2 Гц в ОЕС України з АРЧП на базі пиловугільних (ПВ) ТЕС з резервом 1000 МВт гранична потужність СЕС становить 581 МВт, тоді як для компенсації СЕС потужністю 1 ГВт потрібно генераторів-регуляторів ПУ ТЕС потужністю вже 9,3 ГВт. Такий розкид пояснюється ефектом саморегулювання, який проявляється саме на АРЧП з ПВ ТЕС через низьку швидкодію цього типу регуляторів. Для компенсації 1 ГВт СЕС при інших рівних умовах буде потрібно 310 МВт генераторів-регуляторів ГЕС або 300 МВт споживачів-регуляторів.Визначена величина ефекту саморегулювання. Так, для допустимого відхилення частоти 0,2 Гц тільки за рахунок цього ефекту в ОЕС України може функціонувати 370 МВт потужностей СЕС. Для відхилення 0,02 Гц гранична потужність СЕС становить 38 МВт. General Energy Institute of the National Academy of Sciences of Ukraine 2016-06-10 Article Article application/pdf https://systemre.org/index.php/journal/article/view/543 10.15407/pge2016.02.034 System Research in Energy; No. 2 (45) (2016): The Problems of General Energy; 34-42 Системні дослідження в енергетиці; № 2 (45) (2016): Проблеми загальної енергетики; 34-42 2786-7102 2786-7633 uk https://systemre.org/index.php/journal/article/view/543/479