Контроль двопараметричних технологічних процесів
An urgent practical task is to ensure the serviceability and safety of complex technical and information systems by monitoring their current states. Additionally, an important task is to use control charts to automatically detect the moment when certain limit states are exceeded by the characteristi...
Gespeichert in:
| Datum: | 2024 |
|---|---|
| Hauptverfasser: | , |
| Format: | Artikel |
| Sprache: | Ukrainian |
| Veröffentlicht: |
General Energy Institute of the National Academy of Sciences of Ukraine
2024
|
| Schlagworte: | |
| Online Zugang: | https://systemre.org/index.php/journal/article/view/872 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | System Research in Energy |
Institution
System Research in Energy| id |
oai:www.systemre.org:article-872 |
|---|---|
| record_format |
ojs |
| institution |
System Research in Energy |
| baseUrl_str |
|
| datestamp_date |
2024-12-10T10:51:32Z |
| collection |
OJS |
| language |
Ukrainian |
| topic |
ефективність контрольних карт карти Шухарта карти Хотеллінга головні компоненти статистичний контроль якості кореляція параметрів. |
| spellingShingle |
ефективність контрольних карт карти Шухарта карти Хотеллінга головні компоненти статистичний контроль якості кореляція параметрів. Volodarskyi, Yevhen Kozyr, Oleh Контроль двопараметричних технологічних процесів |
| topic_facet |
effectiveness of control charts Shewhart charts Hotelling charts principal components statistical quality control correlation of parameters. ефективність контрольних карт карти Шухарта карти Хотеллінга головні компоненти статистичний контроль якості кореляція параметрів. |
| format |
Article |
| author |
Volodarskyi, Yevhen Kozyr, Oleh |
| author_facet |
Volodarskyi, Yevhen Kozyr, Oleh |
| author_sort |
Volodarskyi, Yevhen |
| title |
Контроль двопараметричних технологічних процесів |
| title_short |
Контроль двопараметричних технологічних процесів |
| title_full |
Контроль двопараметричних технологічних процесів |
| title_fullStr |
Контроль двопараметричних технологічних процесів |
| title_full_unstemmed |
Контроль двопараметричних технологічних процесів |
| title_sort |
контроль двопараметричних технологічних процесів |
| title_alt |
CONTROL CHARTS FOR CORRELATED PROCESS PARAMETERS |
| description |
An urgent practical task is to ensure the serviceability and safety of complex technical and information systems by monitoring their current states. Additionally, an important task is to use control charts to automatically detect the moment when certain limit states are exceeded by the characteristic features (parameters) of the technological process. In practice, it is quite common for characteristic features to be correlated. The presence of correlation affects the effectiveness of control charts in determining the moment of process disruption. The study objective is to compare the effectiveness of using different control chart types to control a correlated parameter process. The following control charts were studied: Shewhart, Hotelling, and modified Shewhart charts − principal component charts. Numerical modeling of a two-parameter process was conducted with the introduction of a non-random change in one of them at two control points, i.e., the process disorder was modeled at the appropriate time points. Subsequently, statistical studies of the modeled process were conducted using three types of control charts. The results revealed that the Shewhart charts did not reveal any process disruption, which is explained by the correlation of the parameters. Hotelling charts revealed a processing disorder at two points, but they do not indicate the cause of the disorder. The calculated partial Hotelling criterion did not indicate the cause of the disorder. The principal component charts revealed both the presence of a process disorder in two points and identified which parameter caused the disorder. This result demonstrates the effectiveness of principal component charts in detecting process disorder with correlated parameters, as well as their superiority over other charts that were studied. In addition, with an increase in the number of parameters, this method becomes even more effective, as it allows to reduce the number of parameters studied while maintaining their statistical significance. |
| publisher |
General Energy Institute of the National Academy of Sciences of Ukraine |
| publishDate |
2024 |
| url |
https://systemre.org/index.php/journal/article/view/872 |
| work_keys_str_mv |
AT volodarskyiyevhen controlchartsforcorrelatedprocessparameters AT kozyroleh controlchartsforcorrelatedprocessparameters AT volodarskyiyevhen kontrolʹdvoparametričnihtehnologíčnihprocesív AT kozyroleh kontrolʹdvoparametričnihtehnologíčnihprocesív |
| first_indexed |
2025-09-24T17:34:08Z |
| last_indexed |
2025-09-24T17:34:08Z |
| _version_ |
1850410290009604096 |
| spelling |
oai:www.systemre.org:article-8722024-12-10T10:51:32Z CONTROL CHARTS FOR CORRELATED PROCESS PARAMETERS Контроль двопараметричних технологічних процесів Volodarskyi, Yevhen Kozyr, Oleh effectiveness of control charts, Shewhart charts, Hotelling charts, principal components, statistical quality control, correlation of parameters. ефективність контрольних карт, карти Шухарта, карти Хотеллінга, головні компоненти, статистичний контроль якості, кореляція параметрів. An urgent practical task is to ensure the serviceability and safety of complex technical and information systems by monitoring their current states. Additionally, an important task is to use control charts to automatically detect the moment when certain limit states are exceeded by the characteristic features (parameters) of the technological process. In practice, it is quite common for characteristic features to be correlated. The presence of correlation affects the effectiveness of control charts in determining the moment of process disruption. The study objective is to compare the effectiveness of using different control chart types to control a correlated parameter process. The following control charts were studied: Shewhart, Hotelling, and modified Shewhart charts − principal component charts. Numerical modeling of a two-parameter process was conducted with the introduction of a non-random change in one of them at two control points, i.e., the process disorder was modeled at the appropriate time points. Subsequently, statistical studies of the modeled process were conducted using three types of control charts. The results revealed that the Shewhart charts did not reveal any process disruption, which is explained by the correlation of the parameters. Hotelling charts revealed a processing disorder at two points, but they do not indicate the cause of the disorder. The calculated partial Hotelling criterion did not indicate the cause of the disorder. The principal component charts revealed both the presence of a process disorder in two points and identified which parameter caused the disorder. This result demonstrates the effectiveness of principal component charts in detecting process disorder with correlated parameters, as well as their superiority over other charts that were studied. In addition, with an increase in the number of parameters, this method becomes even more effective, as it allows to reduce the number of parameters studied while maintaining their statistical significance. Актуальною практичною задачею є забезпечення справності та безпечності складних технічних та інформаційних систем за рахунок моніторингу їх поточних станів. Крім того, важливою задачею є використання контрольних карт для автоматичного виявлення моменту перевищення певного граничного стану характерними ознаками (параметрами) технологічного процесу. На практиці достатньо часто зустрічаються випадки, коли характерні ознаки є корельованими. Наявність кореляції впливає на ефективність контрольних карт по визначенню моменту розладнання технологічного процесу. Метою роботи є порівняльний аналіз ефективності використання різновидів контрольних карт, що використовуються для забезпечення знаходження процесу у статично керованому стані, для випадку, коли параметри корельовані. У роботі досліджувались контрольні карти: Шухарта, Хотеллінга та модифіковані карти Шухарта – карти на головних компонентах. Було проведено чисельне моделювання двопараметричного процесу із введенням в один із них невипадкової зміни у двох контрольованих точках, тобто моделювалось розладнання процесу у відповідні моменти часу. В подальшому були проведені статистичні дослідження змодельованого процесу із використанням трьох різновидів контрольних карт. Отримані результати аналізу встановили, що карти Шухарта не виявили розладу технологічного процесу, що пояснюється корельованістю параметрів. Карти Хотеллінга виявили розлад процесу у двох точках, але вони не вказують на причину розладу. Розрахований частковий критерій Хотеллінга не вказав на причину розладу. Карти на головних компонентах виявили як наявність розладу процесу у двох точках, так і встановили, який саме параметр став причиною розладу. Даний результат свідчить про ефективність карт на головних компонентах у виявленні розладу процесу із корельованими параметрами, а також їх перевагу над іншими картами, що досліджувались. Крім того, із збільшенням кількості параметрів даний метод стає ще ефективнішим, бо дозволяє зменшити кількість досліджуваних параметрів із збереженням їх статистичної значимості. General Energy Institute of the National Academy of Sciences of Ukraine 2024-11-28 Article Article application/pdf https://systemre.org/index.php/journal/article/view/872 10.15407/srenergy2024.04.077 System Research in Energy; No. 4 (80) (2024): System Research in Energy; 77-87 Системні дослідження в енергетиці; № 4 (80) (2024): Системні дослідження в енергетиці; 77-87 2786-7102 2786-7633 uk https://systemre.org/index.php/journal/article/view/872/780 |