О ВЛИЯНИИ ОЗОНА НА ХАРАКТЕРИСТИКИ КОРОННОГО РАЗРЯДА В ВОЗДУХЕ
The influence of the ozone as well as the humidity and air pressure on the current and voltage corona discharge in gap ~wire- cylinder" is studying. It is shown that negative corona discharge compared with positive is more sensitive to changing parameters of the gas environment Increasing p...
Saved in:
| Date: | 2012 |
|---|---|
| Author Affiliations: |
|
| Keywords: | keywords |
| Main Authors: | , , |
| Format: | Article |
| Language: | Ukrainian |
| Published: |
Інститут електродинаміки НАН України, Київ
2012
|
| Subjects: | |
| Online Access: | https://techned.org.ua/index.php/techned/article/view/1382 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Journal Title: | Technical Electrodynamics |
| Download file: |
|
Institution
Technical Electrodynamics| _version_ | 1870204790316728320 |
|---|---|
| author | Блага , А.В. Божко , И.В. Бржезицкий , В.А. |
| author_facet | Блага , А.В. Божко , И.В. Бржезицкий , В.А. |
| author_institution_txt_mv | [
{
"author": "А.В. Блага ",
"institution": "Национальный технический университет Украины «Киевский политехнический институт», пр. Победы, 37, Киев, 03056, Украина"
},
{
"author": "И.В. Божко ",
"institution": "Институт электродинамики НАН Украины, пр. Победы, 56, Киев-57, 03680, Украина"
},
{
"author": "В.А. Бржезицкий ",
"institution": "Национальный технический университет Украины «Киевский политехнический институт», пр. Победы, 37, Киев, 03056, Украина"
}
] |
| author_sort | Блага , А.В. |
| baseUrl_str | https://techned.org.ua/index.php/techned/oai |
| collection | OJS |
| datestamp_date | 2023-01-26T18:07:34Z |
| description | The influence of the ozone as well as the humidity and air pressure on the current and voltage corona discharge in gap ~wire- cylinder" is studying. It is shown that negative corona discharge compared with positive is more sensitive to changing parameters of the gas environment Increasing partial pressures of water vapor and ozone in the air makes more voltage and lower current of corona discharge. The sensitivity of current and voltage negative corona with respect to the partial pressure of ozone is above 10 time more titan one of water. References 9, figures 5. |
| first_indexed | 2026-06-16T01:26:26Z |
| format | Article |
| fulltext |
ISSN 1607-7970. . . 2012. 4 25
537.523.3
1, 2, , 1,
1 – « »,
. , 37, , 03056, ,
2 – ,
. , 56, -57, 03680, .
,
« ». ,
. -
. -
, . . 9, . 5.
: , , , , , ,
( ) -
. , , -
.
[7,8].
, , -
. [5,9] , > 0,1
,
-
. ,
, [7,8].
, , -
, [4]
( , , ) [3]. ,
,
.
-
.
.
. 1. .
. -
. ( , -
). (
, ).
. -
, , -
. , –
. , , -
254,7 .
« » ( .
1). 1 -
22,7 . 7 0,25 0,8 .
. 4 5 -
, -
2.
5, ,
© ., ., ., 2012
26 ISSN 1607-7970. . . 2012. 4
1. 3 , – .
6
, 8 – -
2 1.
-
. -
, ,
. -
( )
DS 1012.
.
-
« » -
.
, -
Q=5
la=20 .
0,1 , -
2…3 .
.
. 2, -
( 1, 2) ( 3, 4)
d =0,8 -
=0 ( 1, 3) =2,4
2, 4), p=775 , 291 ,
=70%.
-
: Up
Ip. 1 2 ,
-
. ( )
Up=15 -
Up 16 ( Ip=185 ).
Up=15 ,
Ip 185
125 . ( 3, 4) -
Ip
, ( 1, 2).
d . d -
0,8…0,25 ( 30%)
( d = 0,8 ) -
.
-
.
. 3, Up( ),
: Ip=100 , p=775 ,
=70%, T=291 , d =0,25 . , -
-
dUp/ , ( Up) -
. Up 0…0,3; 0,3…1,0 1…2,4 , -
, 3000; 1100 200 . , -
.
Ip : 0…2,7 150 10 .
K
3
8
2
1
4
5
6 6
7
3
4
28
. 1
1
2
3
4
Up, 11 12 13 14 15 16 17
0
40
80
120
160
Ip,
. 2
C, /
13
14
15
0 0,4 0,8 1,2 2,41,6 2
Up,
. 3
ISSN 1607-7970. . . 2012. 4 27
[7,8]. p
U , Up, -
Ip .
. 4.
, p=770 ( 1,3) p = 838
2,4) ( 1,2) =2,05
( 3,4) , ( =65%, T=291 ).
, Up
. Ip=100
p=770 Up Up 1,3 , p=838
Up 1,4 .
Ip: Ip=200
Up 1,5 2 , ,
p=770 838 .
I , -
( 1,2) ( -
) 300…350 ( . 4 )
p.
I 240 ( 3) I 280
4) p=770 838 .
-
, , -
,
[7,8]. . 5 ,
=35% ( 1,3) =65%
2,4) ( 1,2) =2,1
( 3,4) ( =776 ,
=291 ). 1 2 , -
-
U Up 700 (
Ip) Ip 40 ( -
Up ).
( =35%) , -
65% U ,
Up Ip. -
U 1,8 , U
Ip 70 ( . 5, 1,3 -
). Ip 70 , , , U -
, .
=35…70% I
320…300 (~7%), ( 1,2, . 5, ). -
I 20%.
. -
,
2H Op
SOp . -
U Ip
Bp ,
2H Op
SOp .
Bp =770 ,
2H Op =10 (H=65%, T=291 ), os
p =0, Ip =200 , U =16 .
-
=0…1 (
SOp =0,35 ). , -
, . -
. , -
. , , -
12 13 14 15 1716 18 19
Ip,
0
80
160
40
120
200
240
280
1
2
3
4
Up,
. 4
10 11 12 13 1514 16 17 Up,
0
80
160
40
120
200
240
280 1
2
4
3
Ip,
. 5
28 ISSN 1607-7970. . . 2012. 4
,
.
U / Bp Ip/ Bp , U /
2H Op , Ip/
2H Op , U /
3Op , Ip/
3Op ,
12 0,7 150 8 4600 260
, -
.
[7,8,9] , ,
. , -
, 3
-, H20-, OH-, O- H-. ,
,
e + O3 3
-, e + H2O H20-
e + H2O + 3,2 OH- + H, e + H2O + 3,6 O- + H2, e + H2O + 4,25 H- + OH,
[6].
H2O , ,
U .
3
-,
=2,1 , H20- (0,9 ), - (1,47 ) -
(1,83 ) [6], .
, ,
(3 5) , 3
-
. , (
3 )
Up Up .
, , -
, , ( 90%) -
, [1,2]. -
, .
. -
, , -
. , ,
I .
,
[1,2,7 9], .
, -
, « », -
( 30%), « -
». -
« » .
, , -
.
2H Op =6…12
( =35…70%)
2H Op
U /
2H Op 150 , – Ip/ 2H Op 8 .
3Op = 0…0,35
: U /
3Op 4600 , Ip/
3Op 260 .
ISSN 1607-7970. . . 2012. 4 29
1. ., ., . .
// . – 2000. – . 26. – 2. – . 172–178.
2. ., ., . -
// . – 1994. – . 20. – 6. – .
571–584.
3. . . – : , 1984. – 208 .
4. . . – .: . . -
. , . 22. . – 1963. – 3. – C. 132–145.
5. ., ., . -
// . – 2007. – 6. – . 3–8.
6. . . – .: , 1987. – 592 .
7. Becker K.H., Kogelschatz U., Schoenbach K.H., Barker R.I. Non-Equilibrium Air Plasmas at Atmospheric
Pressure. – Institute of Physics Publishing Bristol and Philadelphia, 2005. – 682 p.
8. Fridman A. Plasma Chemistry. – Cambridge university press, 2008. – 1022 p.
9. Ryo Ono, Tetsuji Oda. Dynamis of ozone and OH radicals generated by pulsed corona discharge in humid-air
flow reactor measured by laser spectroscopy // Journal of Applied Physics. – 2003. – Vol. 93. – 10. – Pp. 5876–5882.
537.523.3
1, 2, , 1, ,
1 – « »,
. , 37, , 03056, ,
2 – ,
. , 56, -57, 03680, .
, -
« ». , -
.
. -
, . . 9, . 5.
: , , , , , , .
THE INFLUENCE OF OZONE ON CHARACTERISTICS OF CORONA DISCHARGE IN AIR
A.V.Blaga1, I.V.Bozhko2, V.A.Brzhezitsky 1,
1 National Technical University of Ukraine “Kyiv Polytechnic Institute”,
Peremogy ave., 37, Kyiv 56, 03056, Ukraine,
2 Institute of Electrodynamics National Academy of Science of Ukraine,
Peremogy ave., 56, Kyiv-57, 03680, Ukraine.
The influence of the ozone as well as the humidity and air pressure on the current and voltage corona discharge in gap "wire-
cylinder" is studying. It is shown that negative corona discharge compared with positive is more sensitive to changing parameters of
the gas environment. Increasing partial pressures of water vapor and ozone in the air makes more voltage and lower current of
corona discharge. The sensitivity of current and voltage negative corona with respect to the partial pressure of ozone is above 10
time more than one of water. References 9, figures 5.
Key words: corona discharge, current, voltage, air, pressure, ozone, humidity.
1. Akishev Ju.S., Grushin M.E., Kochetov I.V. About a transition the numerous streamers negative corona in atmospheric air
glow discharge mode // Fizika plazmy. – 2000. – Vol. 26. – 2. – Pp.172–178. (Rus)
2. Akishev Ju.S., Deriugin A.A., Karalnik V.B. Experimental study and numerical simulation of atmospheric DC glow dis-
charge atmospheric pressure // Fizika plazmy. – 1994. – Vol. 20. – 6. – Pp. 571–584. (Rus)
3. Bakhtaev Sh.A. Corona discharge at mikrowires. Almaty: Nauka, 1984. – 208 p. (Rus)
4. Bikenin I.Kh. Methods of measuring ozone concentrations// Nauchnye trudy Akademii kommunalnogo khoziaistva im.
Pamfilova. – 1963. –Vol. 22. Vodosnabzhenie. – 3. – Pp. 132–145. (Rus)
5. Bozhko I.V., Aristov Ju.V., Belinskii V.V. Influence of humidity and movement of air on the properties of positive corona //
Tekhnichna elektrodynamìka. – 2007. – 6. –Pp. 3–8. (Rus)
6. Raiser Ju.P. Physics of gas discharge. – Moskva: Nauka, 1987. – 592 p.( Rus)
7. Fridman A. Plasma Chemistry. – Cambridge university press, 2008. – 1022 p.
8. Becker K.H., Kogelschatz U., Schoenbach K.H., Barker R.I. Non-Equilibrium Air Plasmas at Atmospheric Pressure. – In-
stitute of Physics Publishing Bristol and Philadelphia, 2005. – 682 p.
9. Ryo Ono, Tetsuji Oda. Dynamis of ozone and OH radicals generated by pulsed corona discharge in humid-air flow reactor
measured by laser spectroscopy // Journal of Applied Physics. – 2003. – Vol. 93. – 10. – Pp. 5876–5882.
02.12.2011
Received 02.12.2011
|
| id | techned_org_ua-article-1382 |
| institution | Technical Electrodynamics |
| keywords_txt_mv | keywords |
| language | Ukrainian |
| last_indexed | 2026-06-16T01:26:26Z |
| publishDate | 2012 |
| publisher | Інститут електродинаміки НАН України, Київ |
| record_format | ojs |
| resource_txt_mv | technedorgua/65/4b024fa41d84bd694114dcccfd470d65.pdf |
| spelling | techned_org_ua-article-13822023-01-26T18:07:34Z THE INFLUENCE OF OZONE ON CHARACTERISTICS OF CORONA DISCHARGE IN AIR О ВЛИЯНИИ ОЗОНА НА ХАРАКТЕРИСТИКИ КОРОННОГО РАЗРЯДА В ВОЗДУХЕ Блага , А.В. Божко , И.В. Бржезицкий , В.А. corona discharge current voltage air pressure ozone humidity коронный разряд ток напряжение воздух озон влажность давление The influence of the ozone as well as the humidity and air pressure on the current and voltage corona discharge in gap ~wire- cylinder" is studying. It is shown that negative corona discharge compared with positive is more sensitive to changing parameters of the gas environment Increasing partial pressures of water vapor and ozone in the air makes more voltage and lower current of corona discharge. The sensitivity of current and voltage negative corona with respect to the partial pressure of ozone is above 10 time more titan one of water. References 9, figures 5. Проведены исследования влияния озона, а также влажности и давления воздуха на ток и напряжение коронного разряда в межэлектродном промежутке «нить-цилиндр». Показано, что отрицательная корона по сравнению с положительной более чувствительна к изменению параметров газовой среды. Увеличение в воздухе парциальных давлений паров воды и озона приводит к увеличению напряжения горения разряда и снижению разрядного тока. Чувствительность тока и напряжения отрицательной короны к изменению парциального давления примеси озона на порядок выше, чем при аналогичном изменении примеси паров воды. Библ. 9, рис. 5. Інститут електродинаміки НАН України, Київ 2012-05-18 Article Article application/pdf https://techned.org.ua/index.php/techned/article/view/1382 Tekhnichna Elektrodynamika; No. 4 (2012): TEKHNICHNA ELEKTRODYNAMIKA; 025 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; № 4 (2012): ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА; 025 2218-1903 1607-7970 uk https://techned.org.ua/index.php/techned/article/view/1382/1264 Авторське право (c) 2023 ТЕХНІЧНА ЕЛЕКТРОДИНАМІКА https://creativecommons.org/licenses/by-nc-nd/4.0 |
| spellingShingle | коронный разряд ток напряжение воздух озон влажность давление Блага , А.В. Божко , И.В. Бржезицкий , В.А. О ВЛИЯНИИ ОЗОНА НА ХАРАКТЕРИСТИКИ КОРОННОГО РАЗРЯДА В ВОЗДУХЕ |
| title | О ВЛИЯНИИ ОЗОНА НА ХАРАКТЕРИСТИКИ КОРОННОГО РАЗРЯДА В ВОЗДУХЕ |
| title_alt | THE INFLUENCE OF OZONE ON CHARACTERISTICS OF CORONA DISCHARGE IN AIR |
| title_full | О ВЛИЯНИИ ОЗОНА НА ХАРАКТЕРИСТИКИ КОРОННОГО РАЗРЯДА В ВОЗДУХЕ |
| title_fullStr | О ВЛИЯНИИ ОЗОНА НА ХАРАКТЕРИСТИКИ КОРОННОГО РАЗРЯДА В ВОЗДУХЕ |
| title_full_unstemmed | О ВЛИЯНИИ ОЗОНА НА ХАРАКТЕРИСТИКИ КОРОННОГО РАЗРЯДА В ВОЗДУХЕ |
| title_short | О ВЛИЯНИИ ОЗОНА НА ХАРАКТЕРИСТИКИ КОРОННОГО РАЗРЯДА В ВОЗДУХЕ |
| title_sort | о влиянии озона на характеристики коронного разряда в воздухе |
| topic | коронный разряд ток напряжение воздух озон влажность давление |
| topic_facet | corona discharge current voltage air pressure ozone humidity коронный разряд ток напряжение воздух озон влажность давление |
| url | https://techned.org.ua/index.php/techned/article/view/1382 |
| work_keys_str_mv | AT blagaav theinfluenceofozoneoncharacteristicsofcoronadischargeinair AT božkoiv theinfluenceofozoneoncharacteristicsofcoronadischargeinair AT bržezickijva theinfluenceofozoneoncharacteristicsofcoronadischargeinair AT blagaav ovliâniiozonanaharakteristikikoronnogorazrâdavvozduhe AT božkoiv ovliâniiozonanaharakteristikikoronnogorazrâdavvozduhe AT bržezickijva ovliâniiozonanaharakteristikikoronnogorazrâdavvozduhe AT blagaav influenceofozoneoncharacteristicsofcoronadischargeinair AT božkoiv influenceofozoneoncharacteristicsofcoronadischargeinair AT bržezickijva influenceofozoneoncharacteristicsofcoronadischargeinair |