RESEARCHING OPERATING MODES OF ELECTROMECHANICAL ELEVATOR SYSTEM USING VECTOR CONTROLLED ASYNCHRONOUS MOTOR
Elevator systems are one of the main types of vertical transporta tion of people and goods in office and residential buildings. Designing them, electromechanical systems have a number of requirements regarding the safety of operation and the level of energy efficiency of the mechanism in general. Th...
Gespeichert in:
| Datum: | 2022 |
|---|---|
| Hauptverfasser: | , , |
| Format: | Artikel |
| Sprache: | Ukrainian |
| Veröffentlicht: |
Institute of Renewable Energy National Academy of Sciences of Ukraine
2022
|
| Schlagworte: | |
| Online Zugang: | https://ve.org.ua/index.php/journal/article/view/333 |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Назва журналу: | Vidnovluvana energetika |
Institution
Vidnovluvana energetika| id |
veorgua-article-333 |
|---|---|
| record_format |
ojs |
| institution |
Vidnovluvana energetika |
| baseUrl_str |
|
| datestamp_date |
2024-02-09T13:51:13Z |
| collection |
OJS |
| language |
Ukrainian |
| topic |
elevator system vector control positioning accuracy energetic efficiency working error by speed power wastes static load |
| spellingShingle |
elevator system vector control positioning accuracy energetic efficiency working error by speed power wastes static load Pechenik, M. Burian, S. Kotenko, M. RESEARCHING OPERATING MODES OF ELECTROMECHANICAL ELEVATOR SYSTEM USING VECTOR CONTROLLED ASYNCHRONOUS MOTOR |
| topic_facet |
elevator system vector control positioning accuracy energetic efficiency working error by speed power wastes static load ліфтова підйомна установка векторне керування точність позиціонування енергетична ефективність похибка за швидкістю втрати потужності статичне навантаження |
| format |
Article |
| author |
Pechenik, M. Burian, S. Kotenko, M. |
| author_facet |
Pechenik, M. Burian, S. Kotenko, M. |
| author_sort |
Pechenik, M. |
| title |
RESEARCHING OPERATING MODES OF ELECTROMECHANICAL ELEVATOR SYSTEM USING VECTOR CONTROLLED ASYNCHRONOUS MOTOR |
| title_short |
RESEARCHING OPERATING MODES OF ELECTROMECHANICAL ELEVATOR SYSTEM USING VECTOR CONTROLLED ASYNCHRONOUS MOTOR |
| title_full |
RESEARCHING OPERATING MODES OF ELECTROMECHANICAL ELEVATOR SYSTEM USING VECTOR CONTROLLED ASYNCHRONOUS MOTOR |
| title_fullStr |
RESEARCHING OPERATING MODES OF ELECTROMECHANICAL ELEVATOR SYSTEM USING VECTOR CONTROLLED ASYNCHRONOUS MOTOR |
| title_full_unstemmed |
RESEARCHING OPERATING MODES OF ELECTROMECHANICAL ELEVATOR SYSTEM USING VECTOR CONTROLLED ASYNCHRONOUS MOTOR |
| title_sort |
researching operating modes of electromechanical elevator system using vector controlled asynchronous motor |
| title_alt |
ДОСЛІДЖЕННЯ РЕЖИМІВ РОБОТИ ЕЛЕКТРОМЕХАНІЧНОЇ СИСТЕМИ ЛІФТОВОЇ ПІДЙОМНОЇ УСТАНОВКИ ПРИ ВИКОРИСТАННІ ВЕКТОРНО КЕРОВАНОГО АСИНХРОННОГО ЕЛЕКТРОДВИГУНА |
| description |
Elevator systems are one of the main types of vertical transporta tion of people and goods in office and residential buildings. Designing them, electromechanical systems have a number of requirements regarding the safety of operation and the level of energy efficiency of the mechanism in general.
The task of the research is to ensure the accuracy of the specified motion law of the cab within the operating cycle which is required by the terms of the Safety Rules. One of the ways to solve this problem is using new modern electric drive systems, and one of the most promising is the electromechanical system usingvector-controlled induction motor. Using a specific elevator system within the package of applications "MATLAB" was developed a model of electromechanical system for research its static and dynamic operation modes.
The research was done using a given velocity diagram and the absence of a crawling speed period.
Basing on the analysis of research results of positioning accuracy of the elevator system and its power indicators we can say that expediency of using of electromechanical system of the elevator hoisting installation with vector control is proved. The obtained accuracy level working on the specified movement diagram of the elevator system allows to exclude crawling speed period from the general algorithm of movement what allows to decrease level of capital and operational costs, and also to increase of level of productivity of the mechanism as a whole. Bibl. 15, fig. 8. |
| publisher |
Institute of Renewable Energy National Academy of Sciences of Ukraine |
| publishDate |
2022 |
| url |
https://ve.org.ua/index.php/journal/article/view/333 |
| work_keys_str_mv |
AT pechenikm researchingoperatingmodesofelectromechanicalelevatorsystemusingvectorcontrolledasynchronousmotor AT burians researchingoperatingmodesofelectromechanicalelevatorsystemusingvectorcontrolledasynchronousmotor AT kotenkom researchingoperatingmodesofelectromechanicalelevatorsystemusingvectorcontrolledasynchronousmotor AT pechenikm doslídžennârežimívrobotielektromehaníčnoísistemilíftovoípídjomnoíustanovkiprivikoristannívektornokerovanogoasinhronnogoelektrodviguna AT burians doslídžennârežimívrobotielektromehaníčnoísistemilíftovoípídjomnoíustanovkiprivikoristannívektornokerovanogoasinhronnogoelektrodviguna AT kotenkom doslídžennârežimívrobotielektromehaníčnoísistemilíftovoípídjomnoíustanovkiprivikoristannívektornokerovanogoasinhronnogoelektrodviguna |
| first_indexed |
2025-07-17T11:38:35Z |
| last_indexed |
2025-07-17T11:38:35Z |
| _version_ |
1850411315223330816 |
| spelling |
veorgua-article-3332024-02-09T13:51:13Z RESEARCHING OPERATING MODES OF ELECTROMECHANICAL ELEVATOR SYSTEM USING VECTOR CONTROLLED ASYNCHRONOUS MOTOR ДОСЛІДЖЕННЯ РЕЖИМІВ РОБОТИ ЕЛЕКТРОМЕХАНІЧНОЇ СИСТЕМИ ЛІФТОВОЇ ПІДЙОМНОЇ УСТАНОВКИ ПРИ ВИКОРИСТАННІ ВЕКТОРНО КЕРОВАНОГО АСИНХРОННОГО ЕЛЕКТРОДВИГУНА Pechenik, M. Burian, S. Kotenko, M. elevator system vector control positioning accuracy energetic efficiency working error by speed power wastes static load ліфтова підйомна установка векторне керування точність позиціонування енергетична ефективність похибка за швидкістю втрати потужності статичне навантаження Elevator systems are one of the main types of vertical transporta tion of people and goods in office and residential buildings. Designing them, electromechanical systems have a number of requirements regarding the safety of operation and the level of energy efficiency of the mechanism in general. The task of the research is to ensure the accuracy of the specified motion law of the cab within the operating cycle which is required by the terms of the Safety Rules. One of the ways to solve this problem is using new modern electric drive systems, and one of the most promising is the electromechanical system usingvector-controlled induction motor. Using a specific elevator system within the package of applications "MATLAB" was developed a model of electromechanical system for research its static and dynamic operation modes. The research was done using a given velocity diagram and the absence of a crawling speed period. Basing on the analysis of research results of positioning accuracy of the elevator system and its power indicators we can say that expediency of using of electromechanical system of the elevator hoisting installation with vector control is proved. The obtained accuracy level working on the specified movement diagram of the elevator system allows to exclude crawling speed period from the general algorithm of movement what allows to decrease level of capital and operational costs, and also to increase of level of productivity of the mechanism as a whole. Bibl. 15, fig. 8. Ліфтові підйомні установки є одним з основних видів вертикального транспорту людей і вантажів в адміністративних та жилих будівлях. При їх проектуванні та експлуатації до електромеханічних систем пред’являється ряд вимог що стосуються безпеки експлуатації і рівня енергетичної ефек-тивності механізму в цілому. Задача дослідження полягає в забезпеченні необхідної за умовами Правил безпеки, точності відпрацювання заданого закону руху кабіни підйомної установки в межах робочого циклу. Одним з напрямів вирішення даної задачі є використання нових сучасних систем електропривода серед яких одним з найбільш перспективних являється електромеханічна система з використанням векторно керованого асинхронного електродвигуна. На прикладі конкретної ліфтової підйомної установки в межах пакета прикладних програм «MATLAB» розроблена модель електромеханічної системи для виконання досліджень її статичних та динамічних режимів роботи. Дослідження проведено при використанні заданої діаграми швидкості при відсутності періоду дотягування. На базі аналізу результатів досліджень точності позиціонування підйомної установки та її енергетичних показників обґрунтована доцільність використання електромеханічної системи ліфтової підйомної установки з векторним керуванням. Отриманий рівень точності відпрацювання заданої діаграми руху підйомної установки дозволяє виключити з загального алгоритму руху період дотягування, що в свою чергу призводить до зниження рівня капітальних та експлуатаційних затрат, а також до підвищення рівня продуктивності механізму в цілому. Бібл. 15, рис. 8. Institute of Renewable Energy National Academy of Sciences of Ukraine 2022-06-30 Article Article application/pdf https://ve.org.ua/index.php/journal/article/view/333 10.36296/1819-8058.2022.1(68).37-42 Возобновляемая энергетика; № 1(68) (2022): Scientific and Applied Journal Vidnovliuvana energetyka; 37-42 Відновлювана енергетика; № 1(68) (2022): Науково-прикладний журнал Відновлювана енергетика; 37-42 Vidnovluvana energetika ; No. 1(68) (2022): Scientific and Applied Journal Vidnovliuvana energetyka; 37-42 2664-8172 1819-8058 10.36296/1819-8058.2022.1(68) uk https://ve.org.ua/index.php/journal/article/view/333/254 Copyright (c) 2022 Vidnovliuvana Energetyka http://creativecommons.org/licenses/by-nc-nd/4.0 |