OPERATING MODES OF A HYBRID AUTONOMOUS ELECTRIC POWER SYSTEM WITH COMBINED ENERGY SOURCES

The paper analyzes the operating modes of an autonomous hybrid power supply system based on the combined use of wind energy with a permanent magnet synchronous generator, a diesel generator set, and a storage system with bat-teries. The relevance of implementing such systems for private households w...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2026
Автори: Kovalenko , M., Ostapchuk, O., Kovalenko, I., Trukhanov , O., Vyshnevsky , O.
Формат: Стаття
Мова:Українська
Опубліковано: Institute of Renewable Energy National Academy of Sciences of Ukraine 2026
Теми:
Онлайн доступ:https://ve.org.ua/index.php/journal/article/view/619
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Vidnovluvana energetika
Завантажити файл: Pdf

Репозитарії

Vidnovluvana energetika
_version_ 1870287564606275584
author Kovalenko , M.
Ostapchuk, O.
Kovalenko, I.
Trukhanov , O.
Vyshnevsky , O.
author_facet Kovalenko , M.
Ostapchuk, O.
Kovalenko, I.
Trukhanov , O.
Vyshnevsky , O.
author_institution_txt_mv [ { "author": "M. Kovalenko ", "institution": "Національний технічний універси-тет України «Київський політехнічний ін-ститут імені Ігоря Сікорського», м. Київ, Україна" }, { "author": " O. Ostapchuk", "institution": "Національний технічний універси-тет України «Київський політехнічний ін-ститут імені Ігоря Сікорського», м. Київ, Україна, Інститут відновлюваної енергетики НАН України, м. Київ, Україна" }, { "author": " I. Kovalenko", "institution": "Національний технічний універси-тет України «Київський політехнічний ін-ститут імені Ігоря Сікорського», м. Київ, Україна" }, { "author": "O. Trukhanov ", "institution": "Національний технічний універси-тет України «Київський політехнічний ін-ститут імені Ігоря Сікорського», м. Київ, Україна" }, { "author": "O. Vyshnevsky ", "institution": "Національний технічний універси-тет України «Київський політехнічний ін-ститут імені Ігоря Сікорського», м. Київ, Україна" } ]
author_sort Kovalenko , M.
baseUrl_str https://ve.org.ua/index.php/journal/oai
collection OJS
datestamp_date 2026-07-09T12:14:07Z
description The paper analyzes the operating modes of an autonomous hybrid power supply system based on the combined use of wind energy with a permanent magnet synchronous generator, a diesel generator set, and a storage system with bat-teries. The relevance of implementing such systems for private households with high peak loads (up to 20 kW) in the absence of centralized power supply is substantiated. A numerical simulation model has been developed that allows assessing the dynamics of power distribution between sources depending on wind speed and battery charge status. Power distribution dependencies have been constructed at different wind speeds and different battery charge levels. It is shown that the use of a hybrid inverter with MPPT in combination with LiFePO4 batteries allows minimizing the operating time of the fuel generator, using it only when the critical battery discharge threshold (less than 20%) is reached. It has been established that the operation of the diesel generator in the mode of forced battery charging at a power of 70–80% of the nominal provides a significant reduction in specific fuel consumption and an extension of the engine's service life. The introduction of a wind generator with intelligent charge control allows achieving fuel and lubricant savings of 45–65% compared to traditional power supply schemes. The proposed model can be used to de-sign highly efficient autonomous power supply systems. 
doi_str_mv 10.36296/1819-8058.2026.2(85).17-33
first_indexed 2026-07-10T01:00:14Z
format Article
fulltext 17 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ УДК 621.311.61 https://doi.org/10.36296/1819-8058.2026.2(85).17-33 РЕЖИМИ РОБОТИ ГІБРИДНОЇ АВТОНОМНОЇ ЕЛЕКТРОЕНЕРГЕТИЧНОЇ СИСТЕМИ З КОМБІНОВАНИМИ ДЖЕРЕЛАМИ ЕНЕРГІЇ Отримано 23 лют. 2026 р.; рекомендовано до публікації 26 чер. 2026 р. Доступно онлайн 30 чер. 2026 р. Коваленко М. А.1, Остапчук О. В.2, Коваленко І. Я.3, Труханов О. В.4, Вишневський О. В.5 Автор для кореспонденції: Коваленко Михайло, e-mail: kovalenko87ma@gmail.com Анотація. У роботі проведено аналіз режимів функціону- вання автономної гібридної системи енергозабезпечення, що базується на комбінованому використанні енергії ві- тру з синхронним генератором на постійних магнітах, дизель-генераторної установки та системи накопичення з акумуляторними батареями. Обґрунтовано актуаль- ність впровадження таких систем для приватних домого- сподарств з високим піковим навантаженням (до 20 кВт) в умовах відсутності централізованого електропоста- чання. Розроблено чисельну імітаційну модель, яка дає змогу оцінити динаміку розподілу потужностей між дже- релами залежно від швидкості вітру та стану заряду аку- муляторних батарей. Побудовано залежності розподілу потужності за різної швидкості вітру та різного рівня за- ряду акумуляторів. Показано, що, застосовуючи гібрид- ний інвертор з MPPT у поєднанні з накопичувачами LiFePO4, можна мінімізувати час роботи палив- ного генератора, використовуючи його лише в разі досягнення критичного порогу розряду АКБ (менше 20 %). Встановлено, що робота ДГУ в режимі форсованого заряду акумуляторів на потуж- ності 70–80 % від номінальної забезпечує значне зниження питомої витрати палива та подовження міжремонтного ресурсу двигуна. Впровадження вітрогенератора з інтелектуальним керуванням заряду дає змогу досягти економії паливно-мастильних матеріалів на рівні 45–65 % порівняно з тра- диційними схемами живлення. Запропонована модель може бути використана для проєктування високоефективних автономних систем енергозабезпечення. Ключові слова: гібридна енергосистема, вітрогенератор, дизель-генератор, імітаційне моделю- вання, джерело безперебійного живлення, акумуляторна батарея. Перелік використаних позначень та скорочень ВДЕ – відновлювані джерела енергії ДГУ – дизель-генераторна установка ДБЖ – джерело безперебійного живлення ВЕУ – вітроенергетичні установки СЕС – сонячна електростанція АКБ – акумуляторна батарея ККД – коефіцієнт корисної дії Вступ. Трансформація глобального енергетичного роз- витку та процесів в бік децентралізації зумовлює стрі- мке впровадження систем електропостачання на основі ВДЕ. Особливе місце в цьому процесі посідають гібри- дні автономні комплекси, що поєднують різні типи ге- нерації здебільшого електро- та теплової енергії, для за- безпечення відповідного рівня надійності енергопоста- чання віддалених об’єктів, особливо враховуючи регіо- нальний контекст України. Поняття гібридної системи енергоживлення для автоно- мних об’єктів ґрунтується на спільній роботі різних джерел енергії: вітроустановок, сонячних електростан- цій, геліоколекторів, автономних дизель-бензинових енергоустановок, систем накопичування енергії тощо. Замість використання одного джерела (наприклад, СЕС, ефективність якої мінімальна вночі та суттєво залежить від пори року та погодних умов [1] або тільки ДГУ, ро- бота якого пов’язана із суттєвими експлуатаційними ви- тратами [2]) гібридна система об’єднує в собі декілька систем енергоживлення та накопичення [3]. Зазвичай це комбінація відновлюваних джерел (сонячна енергія та енергія вітру) і традиційного резервного агрегату (ДГУ) або потужного блоку акумуляторів. 1 канд. техн. наук, доцент https://orcid.org/0000-0002-5602-2001 2 д-р. техн. наук, професор https://orcid.org/ 0000-0003-3397-2423 3 PhD, асистент https://orcid.org/0000-0003-1097-2041 4 аспірант https://orcid.org/0009-0004-4040-2204 5 асистент https://orcid.org/0000-0001-7814-9030 1, 2, 3, 4, 5 Національний технічний універси- тет України «Київський політехнічний ін- ститут імені Ігоря Сікорського», м. Київ, Україна 2 Інститут відновлюваної енергетики НАН України, м. Київ, Україна 18 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ Головною перевагою такої системи є безперервне за- безпечення енергопостачання об’єктів (побутових, про- мислових) та висока надійність. Наприклад, у вітряну, але хмарну погоду дефіцит сонячної генерації покрива- ється ВЕУ, а надлишки енергії накопичуються в акумуля- торних батареях [4]. Керуванням процесу розподілу, ви- роблення та споживання енергії такої системи забезпечує ДБЖ під керуванням контролера, який у ре- альному часі розподіляє потоки енергії. Використання гібридних систем для живлення автоном- них об’єктів, приватних будинків та різних віддалених споживачів є практично єдиним способом забезпе- чення енергоживлення. Це дає змогу не лише еконо- мити паливо та ресурс автономного генератора, але й створює гнучку мережу, яка адаптується до зміни пого- дних умов. Тобто гібридна система є автономною «міні- енергосистемою» [5], яка є екологічно чистою, малошу- мною та повністю незалежною від центральної мережі. Аналіз джерел літератури показує [6], що перспектив- ним для використання у складі гібридних систем енер- гоживлення є ВЕУ, побудовані на базі синхронних гене- раторів з постійними магнітами [7]. Така ВЕУ може працювати цілодобово, що дає змогу суттєво зменшити ємність АКБ (а отже, і вартість), оскільки енергія надхо- дить рівномірніше протягом доби [8]. У помірних широ- тах спостерігається ідеальний природний баланс між ві- тровою та сонячною енергією: взимку, коли сонячна інсоляція мінімальна (короткий світловий день, хмар- ність, сніг на панелях), активність повітряних мас зазви- чай максимальна, при цьому ВЕУ перекриває дефіцит енергії взимку, який є актуальним для автономних сис- тем опалення та освітлення в холодну пору року. Отже, саме наявність ВЕУ забезпечує стабільність базової ге- нерації, запобігаючи розряджанню АКБ до критичного рівня. Однак проєктування гібридних систем супроводжується значними труднощами через складність внутрішніх фі- зичних процесів: від багатофакторних електромеханіч- них перетворень до складних перехідних режимів у си- лових електронних перетворювачах. Це робить неможливим точне прогнозування роботи системи без використання імітаційного моделювання та сучасного програмного забезпечення, яке дає змогу визначити по- ведінку автономної мережі в різних експлуатаційних ре- жимах. Впровадження автономних гібридних систем на базі ВЕУ, СЕС, ДГУ тощо для приватного сектору є пріоритет- ним завдяки відсутності потреби в додатковому збу- дженні, високому ККД та можливості реалізації без- мультиплікаторного (прямого) приводу [9]. Однак головним викликом залишається стохастична природа вітрового потоку. Оскільки енергія вітру постійно зміню- ється, виникає потреба в динамічній оптимізації шви- дкості обертання турбіни. Для кожної миттєвої швидко- сті повітряного потоку існує лише одна точка оптимального відбору потужності [10]. Для вирішення цієї проблеми в сучасних гібридних сис- темах застосовуються інтелектуальні алгоритми керу- вання, зокрема контролери пошуку точки максимальної потужності [11]. Ці пристрої в реальному часі адаптують електричне навантаження генератора до механічного моменту турбіни, забезпечуючи максимальну енергое- фективність системи за будь-яких метеоумов [12]. Окрім технічних переваг, розвиток вітроенергетики сти- мулює локальний економічний розвиток, створюючи нові робочі місця в інженерному та сервісному секто- рах. Використання чистої енергії вітру дозволяє повні- стю усунути викиди вуглекислого газу під час експлуата- ції, що відповідає стратегії сталого розвитку [13]. Невід’ємним елементом сучасної гібридної системи є підсистема акумулювання з АКБ. Використання сучас- них літій-залізо-фосфатних накопичувачів (LiFePO4) дає змогу згладжувати піки генерації та споживання. Такі АКБ мають високий ресурс (понад 3000–5000 циклів за- ряду / розряду) та термічну стабільність, що гарантує на- дійну роботу автономної системи протягом десятиліть, зводячи до мінімуму екологічні наслідки [14]. Аналіз сучасних гібридних систем [15] характеризується переходом від аналізу окремих складових такої сис- теми до дослідження процесу їх взаємодії та взаємного впливу. Фундаментальні праці вітчизняних та закордон- них учених [16, 17] присвячені питанням інтеграції віт- рових та сонячних установок у локальні електромережі. Основна увага дослідників зосереджена на топологіях силових перетворювачів та методах стабілізації напруги й частоти за змінного навантаження, стабільність цих параметрів є актуальною для автономних споживачів. Також важливим аспектом, що визначає надійність ро- боти та високі енергетичні показники, є використання як джерела електроенергії електромеханічних перетворю- вачів з постійними магнітами. Безмультиплікаторне ви- конання під час реалізації технічних рішень ВЕУ для ав- тономних енергосистем я дає змогу зменшити втрати на збудження та підвищити надійність [18]. Однак склад- ність керування такими системами потребує впрова- дження інтелектуальних алгоритмів [19]. Аналіз джерел свідчить про те, що використання алгоритмів керування є ключовим фактором підвищення ККД системи за ни- зьких швидкостей вітру [20]. Використання в гібридних системах літій-залізо-фосфат- них накопичувачів сприяє підвищенню терміну експлу- атації обладнання та зростанню швидкості реакції в разі появи пікових навантажень. Проте питання динамічної взаємодії між різними типами джерел та накопичувачів у перехідних режимах все ще потребує глибшого ви- вчення через імітаційне моделювання. Актуальність роботи зумовлена необхідністю забезпе- чення енергетичної стійкості об’єктів в умовах нестабі- льності централізованих мереж та зростання вартості традиційних енергоносіїв. Впровадження гібридних си- стем з комбінованими джерелами (ВЕС, системи нако- пичення з АКБ і традиційні електромеханічні установки 19 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ з ДГУ) дає змогу мінімізувати вплив стохастичного хара- ктеру відновлюваної енергії на споживача. Тому дослі- дження режимів роботи таких систем є актуальним на- уково-практичним завданням. Мета роботи. Дослідження режимів роботи автономної електроенергетичної системи з комбінованими джере- лами енергії шляхом чисельного імітаційного моделю- вання, що дає змогу оцінити взаємодію між різними джерелами генерації та накопичувачами енергії в різ- них експлуатаційних режимах. Це сприятиме забезпе- ченню стабільного енергоживлення автономних об’єктів з урахуванням стохастичного характеру віднов- люваних джерел енергії. На рис. 1 наведено конфігурацію пропонованої гібрид- ної системи електроживлення на прикладі забезпе- чення потреб приватного будинку. Вітроустановка ДБЖ з MPPT НавантаженняАКБ ДГУ ЩЕ Рис. 1. Гібридна система електроживлення: ДГУ – ди- зель-генераторна установка; ДБЖ з MPPT – гібрид- ний напівпровідниковий інвертор з системою MPPT; ЩЕ – електричний комутаційний щит Кожен з елементів системи живлення виконує свою фу- нкцію. ДГУ виконує роль резервного джерела або вико- ристовується за значних пікових навантажень спожи- вача. Вона використовується в тому разі, коли акумулятори розряджені, а сили вітру недостатньо для покриття потреб споживача. Крім того, ДГУ гарантує 100 % автономності системи в будь-яку негоду. Вітроустановка в пропонованій системі є головним від- новлюваним джерелом електроенергії. У цій роботі ро- зглядається безмультиплікаторна ВЕУ із синхронним ге- нератором на постійних магнітах, що генеруює змінний струм змінної частоти, який подається на вхід MPPT ко- нтролера ДБЖ. За достатньої сили вітру надлишок поту- жності використовується для заряджання АКБ. За піко- вих навантажень чи за слабкого вітру недостача потужності покривається за рахунок енергії АКБ. ДБЖ з MPPT (гібридний інвертор) є головним елемен- том цвєї системи: забезпечує максимально можливу по- тужність вітрогенератора за поточної швидкості вітру; перетворює постійну напругу АКБ на змінну; керує заря- дом / розрядом АКБ від вітру чи дизель-генератора від- повідно до режиму роботи чи навантаження; забезпе- чує контроль, моніторинг та захист обладнання, системи й навантаження. АКБ у цій системі виконує важливу функцію енергетич- ного буфера. Вона накопичує надлишки енергії за доста- тньої швидкості вітру і віддає її коли є необхідність. Це підвищує плавність роботи системи – відсутні стрибки напруги та суттєві динамічні процеси. В електричному щиті встановлено захисні комутаційні апарати, які роз- поділяють електроенергію по різних лініях наванта- ження та захищають обладнання. Перелік компонентів та складових досліджуваної гібри- дної системи енергоживлення наведено у табл. 1. Таблиця 1. Ключові компоненти досліджуваної сис- теми № Н ай м е н ув ан н я о б л а - д н а н н я Х ар ак те р и ст и ки В ар ті ст ь , $ 1 Гібридний інвертор Deye SUN-20K- SG01HP3-EU-AM2 3 ф, 20 кВт, 2 MPPT трекери 2500 2 Вітрогенератор PVMARS 10kW 10 кВт, 3-лопа- тевий, старт при 2,5 м/с 5200 3 Система АКБ Pylontech Force-H2 (4 модулі по 14,2 кВт·год) LiFePO4, 57 кВт·год, 384 В, >6000 циклів 20000 4 ДГУ Cummins RS20ACE (Silent) 20 кВт, трифаз- ний, шумоза- хисний кожух, вбудований ATS (автоза- пуск) 8800 5 ЩЕ Schneider Electric / Hager (Custom) Автоматика се- рії Acti9/Volta, ПЗВ, захист від перенапруг (SPD), крос-мо- дулі 1200 6 Всього 37700 Параметри основних компонентів гібридної системи, наведені в табл. 1, використовуються для розробки чи- сельної імітаційної моделі досліджуваної автономної 20 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ електроенергетичної системи. Вибір конкретних компо- нентів здійснений для автономного енергоживлення приватного заміського будинку за умови одночасного ввімкнення всього потужного обладнання (праска, еле- ктрична піч, бойлер, пилосмок і т. ін.). Вибір іншого об- ладнання принципово на впливає на результати роботи системи. Матеріали і результати досліджень. Для дослідження режимів роботи та параметрів автономної гібридної си- стеми при зміні параметрів вітру розроблено комплек- сну чисельну імітаційну модель у програмному середо- вищі MATLAB/Simulink. Параметри навколишнього середовища суттєво вплива- ють на роботу гібридної системи та її вихідні параметри. У моделі реалізовано можливість змінювати швидкість вітру й кута встановлення лопатей. Для оцінки адаптив- ності системи до змінних метеоумов розглядається три випадки моделювання за умови фіксованого значення кута лопатей, що відповідає режиму макси- мального відбору потужності за номінальних наванта- жень: режим номінальної генерації за швидкості вітру v = 6 м/с, дає змогу оцінити сталу роботу вітроустано- вки; режим підвищеної інтенсивності при v = 8 м/с, що характеризує поведінку системи в умовах надлишкової енергії; режим слабого вітрового потоку при v = 4 м/с, що відповідає перевірці роботи системи при мінімаль- них обертах вітрової турбіни. Для спрощення проведення розрахунків, для всіх режи- мів роботи ВЕУ, навантаження приймається ≈ 6,0 кВт, що відповідає ввімкненню ключових споживачів у го- дини пік приватного будинку. Оцінка поведінки системи за випадкової зміни швидко- сті вітру й навантаження, аварійних режимів роботи (пе- ревантаження, коротке замикання і т. ін.) буде прове- дена авторами цього дослідження в подальших роботах. На рис. 2 показано структуру чисельної імітаційної мо- делі автономної гібридної системи енергоживлення. Рис. 2. Структура чисельної імітаційної моделі На рис. 2 показано: 1 – блок, що відповідає за вітрову турбіну та електрогенератор з постійними магнітами; 2 – блок автономної ДГУ; 3 – блок ДБЖ та MPPT; 4 – блок, що відповідає за параметри вибраної АКБ; 5 – на- вантаження системи; 6 – блок, що імітує роботу ЩЕ, тобто виконує роль комутації та захисту навантаження. Підсистема вітрової турбіни та синхронного генератора з постійними магнітами описується відомими рівняннями та залежностями [21]. Відмінністю розробленої підсис- теми вітроустановки є те, що вона дає змогу динамічно перераховувати реальну швидкість обертання вітрової турбіни залежно від фактичної швидкості обертання вала генераторазалежно від його навантаження. Підсистема ДБЖ з MPPT здійснює обробку вхідних сиг- налів та розрахунок величини потужності генерації за таким виразом: ( ) ( )k dc k dc kP V I=  (1) де: Pk – значення потужностіву поточний момент часу; Vdc(k) – напруга на шині постійного струму ДБЖ; Іdc(k) – ве- личина випрямленого струму MPPT контролера. 21 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ Для визначення динаміки системи використовуються блоки затримки на один такт квантування. Розрахунок диференціалів потужності та напругими між діючими та попередніми значеннями виконується згідно з такими виразами: ( ) ( 1) ( ) ( 1) , . k k dc k dc k P P P V V V − −  = −  = − (2) Вихідна потужність системи в будь-який момент часу t визначається як сума потужностей від усіх наявних дже- рел: ( ) ( ) ( )( ) ,вих в mppt ДГ АКБ ДБЖP t P v t P t P t  =  + +   (3) де: Рв – потужність вітроустановки (вітрової турбіни та генератора); ηMPPT – ККД контролера MPPT; РДГ – потуж- ність ДГУ; РАКБ = f(SoC, IАКБ) – потужність АКБ; ηДБЖ – ККД ДБЖ. Зміна стану заряду АКБ (SoC) описується через дифе- ренціальне рівняння, що дає змогу аналізувати дина- міку процесу в реальному часі. Швидкість зміни стану заряду акумулятора, за зміни навантаження чи швид- кості вітру, з урахуванням номінальної ємності та ко- ефіцієнта корисної дії визначається в такий спосіб: ( ) ( ) ( )АКБ АКБ АКБ н dc н dSoC t I t P t dt С V С  = − = −  (4) де: SoC(t) – поточний стан заряду АКБ; Сн – номінальна ємність акумулятора; РАКБ – миттєва потужність на зати- скачах АКБ; ηАКБ – коефіцієнт корисної дії циклу заряду / розряду. Для практичного аналізу результатів чисельного моде- лювання зручно використовувати інтегральну форму за певний проміжок часу [t0, t]: ( ) ( ) ( ) 0 0 1 t АКБ АКБ н t dSoC t dSoC t P t dt С = −  (5) Проведемо аналіз роботи системи за швидкості вітру 6,0 м/с, використовуючи розроблену чисельну іміта- ційну модель. На рис. 3 показано результати розрахунку потужностей основних елементів досліджуваної системи. Рис. 3. Результати розрахунку за швидкості вітру 6 м/с На рис. 3 видно, що вітроустановка при заданій швид- кості вітру розвиває максимальну потужність ≈ 6,0 кВт, при цьому потужність споживача становить 4,7 кВт. Надлишок потужності ≈1,3 кВт використовується для заряджання АКБ, що підтверджується відповідним гра- фіком на рис. 3. Та збільшенням рівня заряду АКБ у від- сотках. За низьких величин швидкості вітру (<4 м/с) недостача потужності насамперед компенсується за рахунок енер- гії АКБ. Автономна ДГУ автоматично запускається в разі падінні рівня заряду АКБ нижче 20 %, для запобігання їх глибокого розряду та пошкодження. Результат розрахунку потужності системи за швидкості вітру 4 м/с показано на рис. 4. 22 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ Рис. 4. Результати розрахунку за швидкості вітру 4 м/с На рис. 4 видно, що потужність споживача, у конкрет- ний момент часу, становить ≈6,0 кВт. При цьому потуж- ність вітроустановки становить 3,6 кВт. Недостача поту- жності споживача компенсується за рахунок енергії, накопиченої в АКБ, і становить ≈ 2,4 кВт. При цьому по графіку на рис. 4 видно, що відбувається розряд АКБ. Поведінка системи на часовому інтервалі до 0,5 с (рис. 3, 4) пояснюється особливостями розрахункових процесів в імітаційній моделі. На рис. 5 показано результати моделювання при вико- ристанні резервної ДГУ. Рис. 5. Результати моделювання при використанні резервної ДГУ 23 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ Як видно на рис. 5, у момент часу t = 0,5 с, коли рівень заряду АКБ перетинає критичну позначку SoC у 20 %, сис- тема автоматично вмикає дизель-генератор. Робоча по- тужність ДГУ 14 кВт відповідає 70 % номінальної потуж- ності генератора, що забезпечує оптимальні питомі енерговитрати палива. Потужність ДГУ перевищує пото- чну потужність споживача у 6,0 кВт та його дефіцит у 2,4 кВт, тож більша частина енергії спрямовується на за- ряд акумуляторів. Це відображено на графіку потужності АКБ, де крива переходить у від'ємну область зі значенням -11,6 кВт, що відповідає інтенсивному заряду. З цього моменту рівень заряду батареї (SoC) починає стрімко зро- стати. Такий підхід до використання енергії ДГУ дає змогу прискорити процес заряджання АКБ та підвищити ефек- тивність використання енергії палива за рахунок роботи генератора в оптимальному режимі навантаження. Використання ВЕУ також сприяє істотній економії па- лива, ресурсу та експлуатаційних витат, пов’язаних з роботою ДГУ. У табл. 2 наведено порівняння експлуа- таційних показників досліджуваної системи енергопо- стачання при використанні ВЕУ сумісно з ДГУ. Таблиця 2. Порівняння експлуатаційних показників систем енергопостачання Параметр порівняння Лише ДГУ (без ВЕУ та АКБ) Гібридна система (ДГУ + ВЕУ + АКБ) Економічний ефект Режим роботи ДГУ Постійний (24 год) Періодичний (~5,5 год/добу) -77 % часу роботи Середнє навантаження на ДГУ ≈6 кВт (30 % від ном.), неефективно ≈14 кВт (70 % від ном.), оптимально +40 % до ККД двигуна Добова генерація від вітру 0 кВт·год ≈86 кВт·год Екологічно чиста енер- гія Добова витрата палива ~72,0 л ~25,0 л ~60,5 % (47,0 л) Витрати на ТО (ум. од) 100 % 23 % Скорочення у 4,3 раза Сумарна добова витрата палива може бути розрахована при визначенні графіку зміни швидкості вітру протягом доби (місяця, року) і визначається в такий спосіб: ( ) 0 ДГУT ДГУ ДГУQ q P dt=   (6) де: TДГУ – час роботи генератора за добу (год), який у гі- бридній системі розраховується: l w ДГУ ДГУ АКБ E E T P  − =  (7) де: qДГУ – питома витрата палива (л/кВт·год), що зале- жить від навантаження; El та Ew – добова енергія спожи- вання та генерації від енергії вітру, відповідно. Аналіз даних табл. 2 показує, що основна економія до- сягається не лише за рахунок прямого заміщення пали- вної енергії енергією вітру, але й завдяки зміщенню ро- бочої точки ДГУ в зону максимального ККД (70–80 % номінальної потужності). У системі лише з ДГУ генера- тор працює при низькій потужності для покриття серед- нього навантаження ≈6 кВт, що призводить до перевит- рати палива та прискореного закоксовування двигуна. У гібридній схемі ДГУ працює за потужності 14 кВт, що дає змогу за короткий час зарядити АКБ та забезпечити по- дальшу роботу системи в безшумному режимі. Висновки Внаслідок виконання цієї роботи проведено комплек- сне дослідження режимів роботи гібридної автономної системи електроживлення, що поєднує вітроенергетич- ну установку на базі СГПМ, ДГУ та систему накопичення енергії з АКБ. Результати імітаційного моделювання да- ють підстави вважати, що: Впровадження системи ДБЖ з MPPT-контролером дає змогу оптимізувати відбір потужності від вітроустановки в широкому діапазоні швидкостей вітру v = 4...10 м/с. Це забезпечує пріоритетне використання відновлюваної енергії та мінімізує цикли роботи паливного генератора. Завдяки комбінованому режиму, за якого ДГУ викорис- товується лише при досягненні порогу розряду АКБ (SoC < 20 %), можливо не лише забезпечити пікове наванта- ження 20 кВт, а й забезпечувати інтенсивне заряджання АКБ. Це скорочує загальний час роботи двигуна внутрі- шнього згоряння та дає змогу досягти економії палива на рівні 45–60 % порівняно з безперервною експлуата- цією генератора. Застосування LiFePO4 АКБ як накопичувача енергії дає змогу ефективно згладжувати стохастичні коливання ві- трової генерації та забезпечувати безперебійне жив- лення споживача. Це значно знижує динамічні наванта- ження на механічні частини вітроустановки та ДГУ, подовжуючи їх ресурс. Окрім економічних переваг, запропонована конфігура- ція суттєво зменшує обсяги шкідливих викидів продук- тів згоряння та кількість відпрацьованого мастила, що робить систему придатною для використання в екологі- чно чутливих автономних зонах. 24 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ ПОСИЛАННЯ 1. Rekioua, D., Mokrani, Z., Kakouche, K. et al. Optimization and intelligent power management control for an autonomous hybrid wind turbine photovoltaic diesel generator with batteries. Sci Rep 13, 21830 (2023). https://doi.org/10.1038/s41598- 023-49067-4. 2. Zoubir Roumila, Djamila Rekioua, Toufik Rekioua, Energy management based fuzzy logic controller of hybrid system wind/photovoltaic/diesel with storage battery, International Journal of Hydrogen Energy, Volume 42, Issue 30, 2017, Pages 19525-19535, ISSN 0360-3199, https://doi.org/10.1016/j.ijhydene.2017.06.006. 3. Saloua Belaid, Djamila Rekioua, Adel Oubelaid, Djamel Ziane, Toufik Rekioua, A power management control and optimization of a wind turbine with battery storage system, Journal of Energy Storage, Volume 45, 2022, 103613, ISSN 2352-152X, https://doi.org/10.1016/j.est.2021.103613. 4. Maulik, A. and Das, D. (2019), Optimal power dispatch considering load and renewable generation uncertainties in an AC–DC hybrid microgrid. IET Gener. Transm. Distrib., 13: 1164-1176. https://doi.org/10.1049/iet-gtd.2018.6502. 5. X. Liu, P. Wang and P. C. Loh, "A Hybrid AC/DC Microgrid and Its Coordination Control," in IEEE Transactions on Smart Grid, vol. 2, no. 2, pp. 278-286, June 2011, doi: 10.1109/TSG.2011.2116162 6. Zoubir Roumila, Djamila Rekioua, Toufik Rekioua,Energy management based fuzzy logic controller of hybrid system wind/photovoltaic/diesel with storage battery, International Journal of Hydrogen Energy, Volume 42, Issue 30, 2017, Pages 19525-19535, ISSN 0360-3199, https://doi.org/10.1016/j.ijhydene.2017.06.006. 7. Khan, M. A., Zeb, K., Sathishkumar, P., Ali, M. U., Uddin, W., Hussain, S., Ishfaq, M., Khan, I., Cho, H.-G., & Kim, H.-J. (2018). A Novel Supercapacitor/Lithium- Ion Hybrid Energy System with a Fuzzy Logic- Controlled Fast Charging and Intelligent Energy Management System. Electronics, 7(5), 63. https://doi.org/10.3390/electronics7050063. 8. Aziz, A. S., Tajuddin, M. F. N., Adzman, M. R., Ramli, M. A. M., & Mekhilef, S. (2019). Energy Management and Optimization of a PV/Diesel/Battery Hybrid Energy System Using a Combined Dispatch Strategy. Sustainability, 11(3), 683. https://doi.org/10.3390/su11030683. 9. Chumack, V., Tsyvinskyi, S., Kovalenko, M., Ponomarev, A., Tkachuk, I. 2020. Mathemathical modeling of a synchronous generator with combined excitation. Eastern-European Journal of Enterprise Technologies. 1, 5 (103) (Feb. 2020), 30–36. doi: 10.15587/1729- 4061.2020.193495. 10. Головко В. М., Коваленко М. А., Коваленко І. Я., Га- ласун І. Р. Математичне моделювання автономної вітроустановки з синхронним генератором магніто- електричного типу. Відновлювальна енергетика. 2020. № 4(63), С. 50–58. doi: 10.36296/1819- 8058.2020.4(63). 11. Yuan, H., Liu, J., Zhou, Y., & Pei, H. (2023). State of Charge Estimation of Lithium Battery Based on Integrated Kalman Filter Framework and Machine Learning Algorithm. Energies, 16(5), 2155. https://doi.org/10.3390/en16052155. 12. Yimen, N., Tchotang, T., Kanmogne, A., Abdelkhalikh Idriss, I., Musa, B., Aliyu, A., Okonkwo, E. C., Abba, S. I., Tata, D., Meva’a, L., Hamandjoda, O., & Dagbasi, M. (2020). Optimal Sizing and Techno-Economic Analysis of Hybrid Renewable Energy Systems—A Case Study of a Photovoltaic/Wind/Battery/Diesel System in Fanisau, Northern Nigeria. Processes, 8(11), 1381. https://doi.org/10.3390/pr8111381. 13. Ge Zhang, Yong Shi, Akbar Maleki, Marc A. Rosen, Optimal location and size of a grid-independent solar/hydrogen system for rural areas using an efficient heuristic approach, Renewable Energy, Volume 156, 2020, Pages 1203-1214, ISSN 0960-1481, https://doi.org/10.1016/j.renene.2020.04.010. 14. Ge Zhang, Yong Shi, Akbar Maleki, Marc A. Rosen, Optimal location and size of a grid-independent solar/hydrogen system for rural areas using an efficient heuristic approach, Renewable Energy, Volume 156, 2020, Pages 1203-1214, ISSN 0960-1481, https://doi.org/10.1016/j.renene.2020.04.010 15. Barun K. Das, Majed A. Alotaibi, Pronob Das, M.S. Islam, Sajal K. Das, Md Alamgir Hossain, Feasibility and techno-economic analysis of stand-alone and grid- connected PV/Wind/Diesel/Batt hybrid energy system: A case study, Energy Strategy Reviews, Volume 37, 2021, 100673, ISSN 2211-467X, https://doi.org/10.1016/j.esr.2021.100673. 16. Коваленко , М. А., Реуцький , М. О., Коваленко, І. Я., Базаров, О. О., & Тітов , Є. О. (2025). Використання джерела безперебійного живлення для зниження експлуатаційних витрат автономного електрогене- ратора. Відновлювана енергетика, (1(80), 29-37. https://doi.org/10.36296/1819-8058.2025.1(80).29- 37. 17. Katsadze, T., Chyzhevskyi, V., Kovalenko, M., Chumack, V., & Buslova, N. (2025). Normalization of non- sinusoidality indicators of magnetoelectric generator under an autonomous mode of operation. Eastern- European Journal of Enterprise Technologies, 3(8 https://doi.org/10.36296/1819-8058.2020.4(63).50-58 https://doi.org/10.36296/1819-8058.2020.4(63).50-58 https://doi.org/10.36296/1819-8058.2025.1(80).29-37 https://doi.org/10.36296/1819-8058.2025.1(80).29-37 25 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ (135), 34–41. https://doi.org/10.15587/1729- 4061.2025.332187. 18. Djaafar Toumi, Djiliani Benattous, Ahmed Ibrahim, H.I. Abdul-Ghaffar, Sergey Obukhov, Raef Aboelsaud, Yacine Labbi, Ahmed A. Zaki Diab, Optimal design and analysis of DC–DC converter with maximum power controller for stand-alone PV system, Energy Reports, Volume 7, 2021, Pages 4951-4960, ISSN 2352-4847, https://doi.org/10.1016/j.egyr.2021.07.040. 19. Hanane Hassani, Faika Zaouche, Djamila Rekioua, Saloua Belaid, Toufik Rekioua, Seddik Bacha, Feasibility of a standalone photovoltaic/battery system with hydrogen production, Journal of Energy Storage, Volume 31, 2020, 101644, ISSN 2352-152X, https://doi.org/10.1016/j.est.2020.101644. 20. Tiewei Song, Lijun Fu, Linlin Zhong, Yaxiang Fan, Qianyi Shang, HP3O algorithm-based all electric ship energy management strategy integrating demand-side adjustment, Energy, Volume 295, 2024, 130968, ISSN 0360-5442, https://doi.org/10.1016/j.energy.2024.130968. 21. Mohammadamin Shirkhani, Jafar Tavoosi, Saeed Danyali, Amirhossein Khosravi Sarvenoee, Ali Abdali, Ardashir Mohammadzadeh, Chunwei Zhang, A review on microgrid decentralized energy/voltage control structures and methods, Energy Reports, Volume 10, 2023, Pages 368-380, ISSN 2352-4847, https://doi.org/10.1016/j.egyr.2023.06.022. https://doi.org/10.15587/1729-4061.2025.332187 https://doi.org/10.15587/1729-4061.2025.332187 26 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ УДК 621.311.61 https://doi.org/10.36296/1819-8058.2026.2(85).17-33 OPERATING MODES OF A HYBRID AUTONOMOUS ELECTRIC POWER SYSTEM WITH COMBINED ENERGY SOURCES Received Feb. 23, 2026; accepted Jun. 26, 2026 Available online June. 30, 2026 Kovalenko M.1, Ostapchuk O.2, Kovalenko I.3, Trukhanov O.4, Vyshnevsky O.5 Author for correspondence: Kovalenko Mykhailo, e-mail: kovalenko87ma@gmail.com Abstract. The paper analyzes the operating modes of an auton- omous hybrid power supply system based on the combined use of wind energy with a permanent magnet synchronous genera- tor, a diesel generator set, and a storage system with bat-teries. The relevance of implementing such systems for private house- holds with high peak loads (up to 20 kW) in the absence of cen- tralized power supply is substantiated. A numerical simulation model has been developed that allows assessing the dynamics of power distribution between sources depending on wind speed and battery charge status. Power distribution dependencies have been constructed at different wind speeds and different battery charge levels. It is shown that the use of a hybrid inverter with MPPT in combination with LiFePO4 batteries allows minimizing the operating time of the fuel generator, using it only when the critical battery discharge threshold (less than 20%) is reached. It has been established that the operation of the diesel generator in the mode of forced battery charging at a power of 70–80% of the nominal provides a significant reduction in specific fuel consumption and an extension of the engine's service life. The introduction of a wind generator with intelligent charge control allows achieving fuel and lubricant savings of 45–65% compared to traditional power supply schemes. The proposed model can be used to de-sign highly efficient autonomous power supply systems. Keywords: hybrid power system, wind generator, diesel generator, simulation modeling, uninterruptible power supply, battery. List of used designations and abbreviations RES – renewable energy sources diesel generator set UPS – uninterruptible power supply wind turbines – wind power plants solar power plant – solar power plant battery – accumulator battery efficiency – efficiency factor Introduction. The transformation of global energy develop- ment and processes towards decentralization leads to the rapid introduction of electricity supply systems based on RES. A special place in this process is occupied by hybrid autonomous complexes combining different types of gen- eration, in most cases electric and thermal energy, to en- sure an appropriate level of reliability of power supply to remote facilities, especially given the regional context of Ukraine. The concept of a hybrid power supply system for autono- mous facilities is based on the joint operation of various en- ergy sources: wind turbines, solar power plants, solar col- lectors, autonomous diesel-gasoline power plants, energy storage systems, etc. Instead of using a single source (for example, a solar power plant whose efficiency is minimal at night and significantly depends on the time of year and weather conditions [1] or only a diesel generator, the op- eration of which is associated with significant operating costs [2]), a hybrid system combines several power supply and storage systems [3]. This is usually a combination of re- newable sources (solar and wind energy) and a traditional backup unit (DGU) or a powerful battery pack. The main advantage of such a system is the continuous pro- vision of power supply to facilities (domestic, industrial) and high reliability. For example, in windy but cloudy weather, the deficit of solar generation is covered by wind turbines, and excess energy accumulates in batteries [4]. The control of the process of distributing, generating and consuming en- ergy of such a system is provided by a UPS controlled by a controller that distributes energy flows in real time. 1 Cand. Sc. (Eng.), Assoc. Prof https://orcid.org/0000-0002-5602-2001 2 Cand. Sc. (Eng.), Assoc. Prof https://orcid.org/0000-0003-1870-2222 3 PhD, assistant https://orcid.org/0000-0003-1097-2041 4 PhD-student https://orcid.org/0009-0008-8491-2678 5 PhD-student https://orcid.org/0009-0007-8222-7477 1, 2, 3, 4, 5 NTUU ”Igor Sikorsky Kyiv Polytech- nic Institute“, Kyiv, Ukraine 2 Leading Researcher, Department No. 1 of Integrated Energy Systems, Institute of Re- newable Energy, NAS of Ukraine, Kyiv, Ukraine 27 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ The use of hybrid systems to power autonomous facilities, private houses and various kinds of remote consumers is practically the only way to provide power supply. This al- lows not only to save fuel and the resource of an autono- mous generator, but also creates a flexible network that adapts to changing weather conditions. That is, a hybrid system is an autonomous "mini-power system" [5], which is environmentally friendly, low-noise and completely inde- pendent of the central grid. The analysis of literature sources shows [6] that wind tur- bines built on the basis of synchronous generators with permanent magnets are promising for use as part of hybrid power supply systems [7]. Such a wind turbine can operate around the clock, which can significantly reduce the capac- ity of the battery (and therefore the cost), since the energy is supplied more evenly throughout the day [8]. In temper- ate latitudes, there is an ideal natural balance between wind and solar energy: in winter, when solar insolation is minimal (short daylight hours, cloudiness, snow on panels), the activity of air masses is usually maximum, while wind turbines cover the energy deficit in winter, which is rele- vant for autonomous heating and lighting systems in the winter season. Therefore, it is the presence of wind tur- bines that ensures the stability of the base generation, pre- venting the battery from being discharged to a critical level. However, the design of hybrid systems is accompanied by significant difficulties due to the complexity of internal physical processes: from multifactor electromechanical transformations to complex transient modes in power elec- tronic converters. This makes it impossible to accurately predict the operation of the system without the use of sim- ulation modeling and modern software that allows you to determine the behavior of the autonomous network in dif- ferent operating modes. The introduction of autonomous hybrid systems based on wind turbines, solar power plants, diesel generators, etc., is a priority for the private sector due to the absence of the need for additional excitation, high efficiency and the pos- sibility of implementing a non-multiplier (direct) drive [9]. However, the main challenge remains the stochastic nature of the wind flow. Since wind energy is constantly changing, there is a need to dynamically optimize the turbine rotation speed. For each instantaneous airflow velocity, there is only one point of optimal power take-off [10]. To solve this problem, modern hybrid systems use intelli- gent control algorithms, in particular maximum power point search controllers [11]. These devices adapt the elec- trical load of the generator to the mechanical torque of the turbine in real time, ensuring maximum energy efficiency of the system in all weather conditions [12]. In addition to technical advantages, the development of wind energy stimulates local economic development, cre- ating new jobs in the engineering and service sectors. The use of clean wind energy allows for the complete elimina- tion of carbon dioxide emissions during operation, which is in line with the sustainable development strategy [13]. An integral element of a modern hybrid system is a battery storage subsystem. The use of modern lithium iron phos- phate storage (LiFePO4) allows smoothing out generation and consumption peaks. Such batteries have a high re- source (more than 3000-5000 charge/discharge cycles) and thermal stability, which guarantees reliable operation of the autonomous system for decades, minimizing environ- mental consequences [14]. The analysis of modern hybrid systems [15] is characterized by a transition from the analysis of individual components of such a system to the study of the process of their inter- action and mutual influence. Fundamental works of do- mestic and foreign scientists [16, 17] are devoted to the in- tegration of wind and solar installations into local power grids. The main attention of researchers is focused on the topologies of power converters and methods for stabilizing voltage and frequency under alternating load, the stability of these parameters is relevant for autonomous consum- ers. Also, an important factor that determines the reliability of operation and high energy performance is the use of elec- tromechanical converters with permanent magnets as a source of electricity. When implementing technical solu- tions of wind turbines for autonomous power systems, the use of a non-multiplier design allows you to reduce excita- tion losses and increase reliability [18]. However, the com- plexity of controlling such systems requires the introduc- tion of intelligent algorithms [19]. Analysis of sources indicates that the use of control algorithms is a key factor in increasing the efficiency of the system at low wind speeds [20]. The use of lithium iron phosphate drives in hybrid systems allows you to increase the service life of the equipment and provide a better reaction speed when peak loads occur. However, the issue of dynamic interaction between differ- ent types of sources and drives in transient modes still needs to be studied more deeply through simulations. The relevance of the work is due to the need to ensure the energy stability of facilities in the conditions of instability of centralized networks and the increase in the cost of tra- ditional energy carriers. The introduction of hybrid systems with combined sources (wind farms, battery storage sys- tems and traditional electromechanical installations with diesel generators) allows minimizing the impact of the sto- chastic nature of renewable energy on the consumer. Therefore, the study of the modes of operation of such sys- tems is an urgent scientific and practical task. Purpose of the work. Study of the operating modes of an autonomous electric power system with combined energy sources by means of numerical simulation modeling, which allows assessing the interaction between different sources of generation and energy storage under different operating modes. This will ensure a stable power supply to autono- mous facilities in the conditions of the stochastic nature of renewable energy sources. 28 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ Fig. 1 shows the configuration of the proposed hybrid power supply system on the example of meeting the needs of a private house. Wind turbine UPS LoadBattery DGS EP Fig. 1. Hybrid power supply system: DGS – diesel generator system; UPS with MPPT – hybrid semiconductor inverter with MPPT system; EP – electrical panel switchboard Each element of the power supply system performs its own function. The diesel generator acts as a backup source or is used at significant peak loads of the consumer. It is used when the batteries are discharged, and the wind force is not enough to cover the needs of the consumer. In addi- tion, the diesel generator guarantees 100% autonomy of the system in any bad weather. The wind turbine in this system is the main renewable source of electricity. This paper discusses a multiplierless wind turbine with a synchronous generator on permanent magnets, generating alternating frequency current, which is supplied to the MPPT input of the UPS controller. With sufficient wind strength, excess power is used to charge the battery. At peak loads or in light winds, the lack of power is covered by battery energy. A UPS with MPPT (hybrid inverter) is the main element of this system: it provides the maximum possible power of the wind turbine at the current wind speed; converts constant battery voltage into alternating voltage; controls the charge/discharge of the battery from the wind or diesel generator in accordance with the mode of operation or load; Provides control, monitoring and protection of equip- ment, systems and loads. The battery in this system performs an important function of an energy buffer. It accumulates excess energy, at suffi- cient wind speed, or gives it away when necessary. This in- creases the smoothness of the system, without power surges and significant dynamic processes. Protective switching devices are installed in the electrical panel, which distribute electricity along different load lines and protect equipment. The list of components of the studied hybrid power supply system is given in Table 1. Table 1. Key components of the investigated system № Eq u ip m e n t n am e Sp e ci fi ca ti o n s C o st , $ 1 Hybrid Inverter Deye SUN-20K- SG01HP3-EU-AM2 3 f, 20 kW, 2 MPPT trackers 2500 2 Wind generator PVMARS 10kW 10 kW, 3-blade, start at 2.5 m/s 5200 3 Battery system Pylontech Force-H2 (4 x 14.2 kWh modules) LiFePO4, 57 kWh, 384 V, >6000 cycles 20000 4 DSU Cummins RS20ACE (Si- lent) 20 kW, three- phase, noise shield, built-in ATS (autostart) 8800 5 EP Schneider Electric / Hager (Custom) Automation of the Acti9/Volta series, RCDs, surge protec- tion (SPD), cross-modules. 1200 6 Total 37700 The parameters of the main components of the hybrid sys- tem, which are given in Table 1, are used to develop a nu- merical simulation model of the autonomous electric power system under study. The choice of specific compo- nents is carried out for autonomous power supply of a pri- vate country house, provided that all powerful equipment (iron, electric stove, boiler, vacuum cleaner, etc.) is turned on at the same time. The choice of other equipment funda- mentally affects the results of the system. Materials and results. To study the operating modes and parameters of an autonomous hybrid system when wind parameters change, a complex numerical simulation model has been developed in the MATLAB/Simulink software en- vironment. Environmental parameters significantly affect the opera- tion of a hybrid system and its initial parameters. The model implements the ability to change the wind speed and the angle of installation of the blades. To assess the adaptability of the system to variable weather conditions, three simulation cases are considered under the condition of a fixed value of the blade angle, which corresponds to the mode of maximum power take-off at nominal loads: the mode of nominal generation at wind speed v = 6 m/s, allows you to evaluate the stable operation of the wind tur- bine; the mode of increased intensity at V = 8 m/s, which characterizes the behavior of the system under conditions 29 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ of excess energy; Low wind flow mode at V = 4 m/s, which corresponds to checking the operation of the system at minimum wind turbine speeds. To simplify calculations, for all modes of operation of the wind turbine, the load is taken ≈ 6.0 kW, which corresponds to the switching on of key consumers during the peak hours of a private house. Assessment of the behavior of the system in case of ran- dom changes in wind speed and load, emergency operating modes (overload, short circuit, etc.) will be carried out by the authors of this study in further work. Fig. 2 shows the structure of a numerical simulation model of an autonomous hybrid power supply system. Fig. 2. Structure of the numerical simulation model Fig. 2 shows: 1 - the unit responsible for the wind turbine and the electric generator with permanent magnets; 2 – autonomous diesel generator unit; 3 - UPS and MPPT unit; 4 - the block responsible for the parameters of the selected battery; 5 – system load; 6 - a block that simulates the op- eration of SHCHE, that is, it acts as a switching and load pro- tection. The subsystem of a wind turbine and a synchronous gener- ator with permanent magnets is described by known equa- tions and dependencies [21]. The difference between the developed wind turbine subsystem is that it allows you to dynamically recalculate the real rotation speed of the wind turbine depending on the actual rotation speed of the gen- erator shaft, depending on its load. The MPPT UPS subsystem processes input signals and cal- culates the generation power using the following expres- sion: ( ) ( )k dc k dc kP V I=  (1) where: Pk is the power value at the current time; Vdc(k) is the voltage on the DC bus of the UPS; Idc(k) is the value of the rectified current MPPT of the controller. To determine the dynamics of the system, delay blocks per one quantization cycle are used. The calculation of power differentials and voltages between the current and previ- ous values is performed according to the following expres- sions: ( ) ( 1) ( ) ( 1) , . k k dc k dc k P P P V V V − −  = −  = − (2) The output power of the system at any point in time t is defined as the sum of the capacities from all available sources: ( ) ( ) ( )( ) ,out w mppt DG B UPSP t P v t P t P t  =  + +   (3) where: Рw – is the power of the wind turbine (wind turbine and generator); ηMPPT – efficiency of the MPPT controller; РDG – diesel generator power; РB=f(SoC, IB) – battery power; ηUPS – UPS efficiency. The change in the state of charge of the battery (SoC) is de- scribed through a differential equation that allows you to analyze the dynamics of the process in real time. The rate of change in the state of charge of the battery, when the load or wind speed changes, taking into account the rated capacity and efficiency, is determined as follows: ( ) ( ) ( )B B B r dc r dSoC t I t P t dt С V С  = − = −  (4) where: SoC(t) – s the current state of charge of the battery; Сr – rated battery capacity; РB – instantaneous battery power; ηB – efficiency of the charge/discharge battery cycle. 30 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ For practical analysis of the results of numerical modeling, it is convenient to use the integral form for a certain period of time [t0, t]: ( ) ( ) ( ) 0 0 1 t B B r t dSoC t dSoC t P t dt С = −  (5) We will analyze the operation of the system at a wind speed of 6.0 m/s, using the developed numerical simula- tion model. Fig. 3 shows the results of calculating the capacities of the main elements of the study system. Fig. 3. Calculation results at a wind speed 6 m/s According to Fig. 3 shows that the wind turbine at a given wind speed develops a maximum power of ≈ 6.0 kW, while the con- sumer power is 4.7 kW. Excess power ≈1.3 kW is used to charge the battery, which is confirmed by the corresponding graph in Fig. 3. And an increase in the battery charge level in %. At low wind speeds (<4 m/s), the lack of power, first of all, is compensated for by the energy of the battery. The au- tonomous diesel generator automatically starts when the battery charge level drops below 20% to prevent deep dis- charge and damage. The result of calculating the power of the system at a wind speed of 4 m/s is shown in Fig. 4. Fig. 4. Calculation results at a wind speed 4 m/s 31 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ Fig. 4 shows that the power of the consumer, at a given time, is ≈6.0 kW. At the same time, the power of the wind turbine is 3.6 kW. The lack of consumer power is compen- sated for by the energy accumulated in the battery and is ≈ 2.4 kW. At the same time, according to the graph in Fig. 4, it can be seen that the battery is discharged. The behavior of the system at a time interval of up to 0.5 s (Figs. 3, 4) is explained by the peculiarities of the calculation processes in the simulation model. Fig. 5 shows the results of simulation when using a backup diesel generator. Fig. 5. Simulation results using a backup diesel generator As can be seen from Fig. 5, at time t = 0.5 s, when the bat- tery charge level crosses the critical SoC mark of 20%, the system automatically turns on the diesel generator. The op- erating power of the 14 kW diesel generator corresponds to 70% of the rated power of the generator, which provides optimal specific energy consumption of fuel. The power of the diesel generator exceeds the current power of the con- sumer of 6.0 kW and its deficit of 2.4 kW, so most of the energy is directed to charging the batteries. This is reflected in the battery power graph, where the curve goes into the negative region with a value of -11.6 kW, which corre- sponds to an intense charge. From this point on, the battery level (SoC) begins to skyrocket. This approach to the use of diesel generator energy allows you to speed up the process of charging the battery and increase the efficiency of using fuel energy, due to the operation of the generator in the optimal load mode. The use of wind turbines also allows you to significantly save fuel, resources and operational costs associated with the operation of the diesel generator. Table 2 shows a comparison of the performance indicators of the studied power supply system when using a wind turbine in conjunc- tion with a diesel generator. Table 2. Comparison of operational indicators of power supply systems Comparison Parameter Diesel generator only (without wind turbines and batteries) Hybrid system (diesel generator + wind turbine + battery) Economic effect Operating mode of the diesel generator Constant (24 hours) Intermittent (~5.5 hours/day) -77% uptime Average load on the diesel generator ≈6 kW (30% of nominal), inefficient ≈14 kW (70% of the nominal), optimally +40% to engine efficiency Daily wind generation 0 kWh ≈86 kWh Environmentally friendly energy Daily fuel consumption ~72.0 l ~25.0 l ~60.5% (47.0 L) Maintenance costs (um. units) 100% 23% 4.3x reduction 32 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ The total daily fuel consumption can be calculated when determining the schedule of changes in wind speed during the day (month, year) and is determined as follows: ( ) 0 DGT DG DGQ q P dt=   (6) where: TDG – is the operating time of the generator per day (hour), which in a hybrid system is calculated: l w DG DG B E E T P  − =  (7) where: qDG – is the specific fuel consumption (l/kWh), which depends on the load; El and Ew are the daily energy con- sumption and generation from wind energy, respectively. Analysis of the data in Table 2 shows that the main savings are achieved not only due to the direct replacement of fuel energy with wind energy, but also due to the displacement of the operating point of the diesel generator unit to the zone of maximum efficiency (70–80% of the rated power). In a DGT-only system, the generator operates at low power to cover an average load of ≈6 kW, which leads to overcon- sumption of fuel and accelerated engine coking. In a hybrid scheme, the diesel generator operates at a power of 14 kW, which allows you to charge the battery in a short time and ensure further operation of the system in silent mode. Conclusions As a result of this work, a comprehensive study of the op- erating modes of a hybrid autonomous power supply sys- tem was carried out, combining a wind power plant based on SGPM, a diesel generator and an energy storage system with a battery. The results of simulation modeling allow us to state the following: The implementation of a UPS system with an MPPT control- ler allows you to optimize the power take-off from the wind turbine in a wide range of wind speeds v = 4...10 m/s. The use of the combined mode, in which the diesel gener- ator is used only when the battery discharge threshold is reached (SoC < 20%), allows not only to meet the peak load of 20 kW but also to provide intensive battery charging. This reduces the overall operating time of the internal com- bustion engine and allows you to achieve fuel savings of 45- 60% compared to continuous operation of the generator. The use of LiFePO4 batteries as an energy storage device effectively smooths out stochastic fluctuations in wind gen- eration and provides an uninterrupted power supply to consumers. This significantly reduces the dynamic loads on the mechanical parts of the wind turbine and diesel gener- ators, extending their life. In addition to economic advantages, the proposed configu- ration significantly reduces the volume of harmful emis- sions of combustion products and the amount of used lub- ricant, making the system suitable for use in environmen- tally sensitive autonomous zones. REFERENCES 1. Rekioua, D., Mokrani, Z., Kakouche, K. et al. Optimization and intelligent power management control for an autonomous hybrid wind turbine photovoltaic diesel generator with batteries. Sci Rep 13, 21830 (2023). https://doi.org/10.1038/s41598- 023-49067-4. 2. Zoubir Roumila, Djamila Rekioua, Toufik Rekioua, Energy management based fuzzy logic controller of hybrid system wind/photovoltaic/diesel with storage battery, International Journal of Hydrogen Energy, Volume 42, Issue 30, 2017, Pages 19525-19535, ISSN 0360-3199, https://doi.org/10.1016/j.ijhydene.2017.06.006. 3. Saloua Belaid, Djamila Rekioua, Adel Oubelaid, Djamel Ziane, Toufik Rekioua, A power management control and optimization of a wind turbine with battery storage system, Journal of Energy Storage, Volume 45, 2022, 103613, ISSN 2352-152X, https://doi.org/10.1016/j.est.2021.103613. 4. Maulik, A. and Das, D. (2019), Optimal power dispatch considering load and renewable generation uncertainties in an AC–DC hybrid microgrid. IET Gener. Transm. Distrib., 13: 1164-1176. https://doi.org/10.1049/iet-gtd.2018.6502. 5. X. Liu, P. Wang and P. C. Loh, "A Hybrid AC/DC Microgrid and Its Coordination Control," in IEEE Transactions on Smart Grid, vol. 2, no. 2, pp. 278-286, June 2011, doi: 10.1109/TSG.2011.2116162. 6. Zoubir Roumila, Djamila Rekioua, Toufik Rekioua,Energy management based fuzzy logic controller of hybrid system wind/photovoltaic/diesel with storage battery, International Journal of Hydrogen Energy, Volume 42, Issue 30, 2017, Pages 19525-19535, ISSN 0360-3199, https://doi.org/10.1016/j.ijhydene.2017.06.006. 7. Khan, M. A., Zeb, K., Sathishkumar, P., Ali, M. U., Uddin, W., Hussain, S., Ishfaq, M., Khan, I., Cho, H.-G., & Kim, H.-J. (2018). A Novel Supercapacitor/Lithium- Ion Hybrid Energy System with a Fuzzy Logic- Controlled Fast Charging and Intelligent Energy Management System. Electronics, 7(5), 63. https://doi.org/10.3390/electronics7050063. 8. Aziz, A. S., Tajuddin, M. F. N., Adzman, M. R., Ramli, M. A. M., & Mekhilef, S. (2019). Energy Management and Optimization of a PV/Diesel/Battery Hybrid Energy System Using a Combined Dispatch Strategy. Sustainability, 11(3), 683. https://doi.org/10.3390/su11030683. 9. Chumack, V., Tsyvinskyi, S., Kovalenko, M., Ponomarev, A., Tkachuk, I. 2020. Mathemathical modeling of a synchronous generator with combined excitation. Eastern-European Journal of Enterprise 33 Відновлювана енергетика. № 2/2026 | Комплексні проблеми енергетичних систем на основі НВДЕ Technologies. 1, 5 (103) (Feb. 2020), 30–36. doi: 10.15587/1729-4061.2020.193495. 10. Holovko V. M., Kovalenko M. A., Kovalenko I. Ya., Halasun I. R. Matematychne modeliuvannia avtonomnoi vitroustanovky z synkhronnym hene- ratorom mahnitoelektrychnoho typu. Vidnovliu-valna enerhetyka,. 2020,. no.№ 4(63), S. 50-–58. doi: 10.36296/1819-8058.2020.4(63). 11. Yuan, H., Liu, J., Zhou, Y., & Pei, H. (2023). State of Charge Estimation of Lithium Battery Based on Integrated Kalman Filter Framework and Machine Learning Algorithm. Energies, 16(5), 2155. https://doi.org/10.3390/en16052155. 12. Yimen, N., Tchotang, T., Kanmogne, A., Abdelkhalikh Idriss, I., Musa, B., Aliyu, A., Okonkwo, E. C., Abba, S. I., Tata, D., Mevaa, L., Hamandjoda, O., & Dagbasi, M. (2020). Optimal Sizing and Techno-Economic Analysis of Hybrid Renewable Energy Systems—A Case Study of a Photovoltaic/Wind/Battery/Diesel System in Fanisau, Northern Nigeria. Processes, 8(11), 1381. https://doi.org/10.3390/pr8111381. 13. Ge Zhang, Yong Shi, Akbar Maleki, Marc A. Rosen, Optimal location and size of a grid-independent solar/hydrogen system for rural areas using an efficient heuristic approach, Renewable Energy, Volume 156, 2020, Pages 1203-1214, ISSN 0960-1481, https://doi.org/10.1016/j.renene.2020.04.010. 14. Ge Zhang, Yong Shi, Akbar Maleki, Marc A. Rosen, Optimal location and size of a grid-independent solar/hydrogen system for rural areas using an efficient heuristic approach, Renewable Energy, Volume 156, 2020, Pages 1203-1214, ISSN 0960-1481, https://doi.org/10.1016/j.renene.2020.04.010. 15. Barun K. Das, Majed A. Alotaibi, Pronob Das, M.S. Islam, Sajal K. Das, Md Alamgir Hossain, Feasibility and techno-economic analysis of stand-alone and grid- connected PV/Wind/Diesel/Batt hybrid energy system: A case study, Energy Strategy Reviews, Volume 37, 2021, 100673, ISSN 2211-467X, https://doi.org/10.1016/j.esr.2021.100673. 16. Kovalenko , M. A., Reutskyi , M. O., Kovalen-ko, I. Ya., Bazarov, O. O., & Titov , Ye. O. (2025). Vy-korystannia dzherela bezperebiinoho zhyvlennia dlia znyzhennia ekspluatatsiinykh vytrat avtonom-noho elektroheneratora. Vidnovliuvana enerhe-tyka, (1(80), 29-37. https://doi.org/10.36296/1819- 8058.2025.1(80).29-37. 17. Katsadze, T., Chyzhevskyi, V., Kovalenko, M., Chumack, V., & Buslova, N. (2025). Normalization of non-sinusoidality indicators of magnetoelectric generator under an autonomous mode of operation. Eastern-European Journal of Enterprise Technologies, 3(8 (135), 34–41. https://doi.org/10.15587/1729- 4061.2025.332187. 18. Djaafar Toumi, Djiliani Benattous, Ahmed Ibrahim, H.I. Abdul-Ghaffar, Sergey Obukhov, Raef Aboelsaud, Yacine Labbi, Ahmed A. Zaki Diab, Optimal design and analysis of DC–DC converter with maximum power controller for stand-alone PV system, Energy Reports, Volume 7, 2021, Pages 4951-4960, ISSN 2352-4847, https://doi.org/10.1016/j.egyr.2021.07.040. 19. Hanane Hassani, Faika Zaouche, Djamila Rekioua, Saloua Belaid, Toufik Rekioua, Seddik Bacha, Feasibility of a standalone photovoltaic/battery system with hydrogen production, Journal of Energy Storage, Volume 31, 2020, 101644, ISSN 2352-152X, https://doi.org/10.1016/j.est.2020.101644. 20. Tiewei Song, Lijun Fu, Linlin Zhong, Yaxiang Fan, Qianyi Shang, HP3O algorithm-based all electric ship energy management strategy integrating demand-side adjustment, Energy, Volume 295, 2024, 130968, ISSN 0360-5442, https://doi.org/10.1016/j.energy.2024.130968. 21. Mohammadamin Shirkhani, Jafar Tavoosi, Saeed Danyali, Amirhossein Khosravi Sarvenoee, Ali Abdali, Ardashir Mohammadzadeh, Chunwei Zhang, A review on microgrid decentralized energy/voltage control structures and methods, Energy Reports, Volume 10, 2023, Pages 368-380, ISSN 2352-4847, https://doi.org/10.1016/j.egyr.2023.06.022. https://doi.org/10.1016/j.esr.2021.100673 https://doi.org/10.1016/j.energy.2024.130968
id veorgua-article-619
institution Vidnovluvana energetika
keywords_txt_mv keywords
language Ukrainian
last_indexed 2026-07-10T01:00:14Z
publishDate 2026
publisher Institute of Renewable Energy National Academy of Sciences of Ukraine
record_format ojs
resource_txt_mv veorgua/a8/b0b83aeb577f3b55d3d1b2b4ea454ca8.pdf
spelling veorgua-article-6192026-07-09T12:14:07Z OPERATING MODES OF A HYBRID AUTONOMOUS ELECTRIC POWER SYSTEM WITH COMBINED ENERGY SOURCES РЕЖИМИ РОБОТИ ГІБРИДНОЇ АВТОНОМНОЇ ЕЛЕКТРОЕНЕРГЕТИЧНОЇ СИСТЕМИ З КОМБІНОВАНИМИ ДЖЕРЕЛАМИ ЕНЕРГІЇ Kovalenko , M. Ostapchuk, O. Kovalenko, I. Trukhanov , O. Vyshnevsky , O. hybrid power system, wind generator, diesel generator, simulation modeling, uninterruptible power supply, battery. гібридна енергосистема, вітрогенератор, дизель-генератор, імітаційне моделювання, джерело безперебійного живлення, акумуляторна батарея. The paper analyzes the operating modes of an autonomous hybrid power supply system based on the combined use of wind energy with a permanent magnet synchronous generator, a diesel generator set, and a storage system with bat-teries. The relevance of implementing such systems for private households with high peak loads (up to 20 kW) in the absence of centralized power supply is substantiated. A numerical simulation model has been developed that allows assessing the dynamics of power distribution between sources depending on wind speed and battery charge status. Power distribution dependencies have been constructed at different wind speeds and different battery charge levels. It is shown that the use of a hybrid inverter with MPPT in combination with LiFePO4 batteries allows minimizing the operating time of the fuel generator, using it only when the critical battery discharge threshold (less than 20%) is reached. It has been established that the operation of the diesel generator in the mode of forced battery charging at a power of 70–80% of the nominal provides a significant reduction in specific fuel consumption and an extension of the engine's service life. The introduction of a wind generator with intelligent charge control allows achieving fuel and lubricant savings of 45–65% compared to traditional power supply schemes. The proposed model can be used to de-sign highly efficient autonomous power supply systems.&amp;nbsp; У роботі проведено аналіз режимів функціонування автономної гібридної системи енергозабезпечення, що базується на комбінованому використанні енергії вітру з синхронним генератором на постійних магнітах, дизель-генераторної установки та системи накопичення з акумуляторними батареями. Обґрунтовано актуальність впровадження таких систем для приватних домогосподарств з високим піковим навантаженням (до 20 кВт) в умовах відсутності централізованого електропо­стачання. Розроблено чисельну імітаційну модель, яка дає змогу оцінити динаміку розподілу потужностей між джерелами залежно від швидкості вітру та стану заряду акумуляторних батарей. Побудовано залежності розподілу потужності за різної швидкості вітру та різного рівня заряду акумуляторів. Показано, що, застосовуючи гібридний інвертор з MPPT у поєднанні з накопичувачами LiFePO4, можна мінімізувати час роботи паливного генератора, використовуючи його лише в разі досягнення критичного порогу розряду АКБ (менше 20 %). Встановлено, що робота ДГУ в режимі форсованого заряду акумуляторів на потужності 70–80 % від номінальної забезпечує значне зниження питомої витрати палива та подовження міжремонтного ресурсу двигуна. Впровадження вітрогенератора з інтелектуальним керуванням заряду дає змогу досягти економії паливно-мастильних матеріалів на рівні 45–65 % порівняно з традиційними схемами живлення. Запропонована модель може бути використана для проєктування високоефективних автономних систем енергозабезпечення.&amp;nbsp; Institute of Renewable Energy National Academy of Sciences of Ukraine 2026-06-30 Article Article application/pdf https://ve.org.ua/index.php/journal/article/view/619 10.36296/1819-8058.2026.2(85).17-33 Vidnovluvana energetika ; No. 2(85) (2026): Scientific and applied Journal renewable energy ; 17-33 Возобновляемая энергетика; № 2(85) (2026): Scientific and applied Journal renewable energy ; 17-33 Відновлювана енергетика; № 2(85) (2026): Науково-прикладний журнал Відновлювана енергетика; 17-33 2664-8172 1819-8058 10.36296/1819-8058.2026.2(85) uk https://ve.org.ua/index.php/journal/article/view/619/530 Copyright (c) 2026 Vidnovluvana energetika
spellingShingle hybrid power system
wind generator
diesel generator
simulation modeling
uninterruptible power supply
battery.
Kovalenko , M.
Ostapchuk, O.
Kovalenko, I.
Trukhanov , O.
Vyshnevsky , O.
OPERATING MODES OF A HYBRID AUTONOMOUS ELECTRIC POWER SYSTEM WITH COMBINED ENERGY SOURCES
title OPERATING MODES OF A HYBRID AUTONOMOUS ELECTRIC POWER SYSTEM WITH COMBINED ENERGY SOURCES
title_alt РЕЖИМИ РОБОТИ ГІБРИДНОЇ АВТОНОМНОЇ ЕЛЕКТРОЕНЕРГЕТИЧНОЇ СИСТЕМИ З КОМБІНОВАНИМИ ДЖЕРЕЛАМИ ЕНЕРГІЇ
title_full OPERATING MODES OF A HYBRID AUTONOMOUS ELECTRIC POWER SYSTEM WITH COMBINED ENERGY SOURCES
title_fullStr OPERATING MODES OF A HYBRID AUTONOMOUS ELECTRIC POWER SYSTEM WITH COMBINED ENERGY SOURCES
title_full_unstemmed OPERATING MODES OF A HYBRID AUTONOMOUS ELECTRIC POWER SYSTEM WITH COMBINED ENERGY SOURCES
title_short OPERATING MODES OF A HYBRID AUTONOMOUS ELECTRIC POWER SYSTEM WITH COMBINED ENERGY SOURCES
title_sort operating modes of a hybrid autonomous electric power system with combined energy sources
topic hybrid power system
wind generator
diesel generator
simulation modeling
uninterruptible power supply
battery.
topic_facet hybrid power system
wind generator
diesel generator
simulation modeling
uninterruptible power supply
battery.
гібридна енергосистема
вітрогенератор
дизель-генератор
імітаційне моделювання
джерело безперебійного живлення
акумуляторна батарея.
url https://ve.org.ua/index.php/journal/article/view/619
work_keys_str_mv AT kovalenkom operatingmodesofahybridautonomouselectricpowersystemwithcombinedenergysources
AT ostapchuko operatingmodesofahybridautonomouselectricpowersystemwithcombinedenergysources
AT kovalenkoi operatingmodesofahybridautonomouselectricpowersystemwithcombinedenergysources
AT trukhanovo operatingmodesofahybridautonomouselectricpowersystemwithcombinedenergysources
AT vyshnevskyo operatingmodesofahybridautonomouselectricpowersystemwithcombinedenergysources
AT kovalenkom režimirobotigíbridnoíavtonomnoíelektroenergetičnoísistemizkombínovanimidžerelamienergíí
AT ostapchuko režimirobotigíbridnoíavtonomnoíelektroenergetičnoísistemizkombínovanimidžerelamienergíí
AT kovalenkoi režimirobotigíbridnoíavtonomnoíelektroenergetičnoísistemizkombínovanimidžerelamienergíí
AT trukhanovo režimirobotigíbridnoíavtonomnoíelektroenergetičnoísistemizkombínovanimidžerelamienergíí
AT vyshnevskyo režimirobotigíbridnoíavtonomnoíelektroenergetičnoísistemizkombínovanimidžerelamienergíí