IMPACT OF A HYDRAULIC DAMPER ON TWO-POSITION POLARIZED ACTUATOR DYNAMICS

A feasibility of reducing a vacuum circuit-breaker actuator armature speed by means of a liquid damper is analyzed. The paper presents comparative calculations of the armature reduced mass motion dynamics with allowance for the hydraulic damper counter forces.

Saved in:
Bibliographic Details
Main Author: Baida, E. I.
Format: Article
Language:Russian
Published: National Technical University "Kharkiv Polytechnic Institute" and State Institution “Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine” 2013
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2013.5.03