Оptimization of power control program switching for a WWER-1000 under transient operating conditions

This paper is devoted to solution of the scientific and technical problem of safe switching of static power control programs for a nuclear power unit with a WWER-1000 under transient operating conditions, so that to minimize the influence of disturbances of external and internal operating parameters...

Full description

Saved in:
Bibliographic Details
Main Authors: Huiyu Zhou, Pelykh, S.N., Odrekhovska, I.O., Maksymova, O.B.
Format: Article
Language:English
Published: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2018
Series:Вопросы атомной науки и техники
Subjects:
Online Access:http://dspace.nbuv.gov.ua/handle/123456789/137360