Thermal and Stress State of the Steam Turbine Control Valve Casing, with the Turbine Operation in the Stationary Modes

The purpose of this paper is to determine the most stressful zones and assess the possibility of plastic deformations of the control valve casing in its crack forma-tion zones, with the K-325 steam turbine operation in the stationary modes. The problem is solved in two stages. First, the steam flow...