Thermal state of the rotor winding of the turbogenerator with direct hydrogen cooling

The temperature field of the rotor of the synchronous turbogenerator is investigated. The temperature distributions in rotor windings of 300 and 550-MW turbogenerators with direct hydrogen cooling of rotor winding are obtained. The transition to more power is implemented by increasing the hydrogen p...