Long-Term Aging Effect on the Crack Growth in the of Main Circulating Pump Casing Material
Fatigue crack growth (FCG) tests on the main circulating pump casing material were conducted at room temperature to investigate the effect of long-term aging at 400°C. It was found that the FCG rate increased with aging time. However, there were similar ∆Kth values for both the virgin material and a...