X-ray line spectrometry in experiments with the aluminium Z-pinch

X-ray line spectrometry with temporal resolution was developed for registration of [He]- and [H]-like aluminium ions spectrum. It was chosen a scheme with scintillator converting X-ray spectrum into the visible image, which was transferred through the flexible optical fiber to the entrance slit of t...

Повний опис

Збережено в:
Бібліографічні деталі
Дата:2010
Автори: Anan’ev, S.S., Dan’ko, S.A., Kalinin, Yu.G., Ye Fan, Qin Yi, Jiang Shuqing, Xue Feibiao, Li Zhenghong, Yang Jianlun, Xu Rongkun
Формат: Стаття
Мова:English
Опубліковано: Національний науковий центр «Харківський фізико-технічний інститут» НАН України 2010
Теми:
Онлайн доступ:https://nasplib.isofts.kiev.ua/handle/123456789/17505
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!
Назва журналу:Digital Library of Periodicals of National Academy of Sciences of Ukraine
Цитувати:X-ray line spectrometry in experiments with the aluminium Z-pinch / S.S. Anan’ev, S.A. Dan’ko, Yu.G. Kalinin, Fan Ye, Yi Qin, Shuqing Jiang, Feibiao Xue, Zhenghong Li, Jianlun Yang, Rongkun Xu // Вопросы атомной науки и техники. — 2010. — № 6. — С. 205-207. — Бібліогр.: 11 назв. — англ.

Репозитарії

Digital Library of Periodicals of National Academy of Sciences of Ukraine
id nasplib_isofts_kiev_ua-123456789-17505
record_format dspace
fulltext
spelling nasplib_isofts_kiev_ua-123456789-175052025-02-23T18:52:30Z X-ray line spectrometry in experiments with the aluminium Z-pinch Спектрометрия рентгеновских линий в экспериментах с алюминиевым Z-пинчем Спектрометрія рентгенівських ліній в експериментах з алюмінієвим Z-пінчeм Anan’ev, S.S. Dan’ko, S.A. Kalinin, Yu.G. Ye Fan Qin Yi Jiang Shuqing Xue Feibiao Li Zhenghong Yang Jianlun Xu Rongkun Диагностика плазмы X-ray line spectrometry with temporal resolution was developed for registration of [He]- and [H]-like aluminium ions spectrum. It was chosen a scheme with scintillator converting X-ray spectrum into the visible image, which was transferred through the flexible optical fiber to the entrance slit of the streak camera. In Z-pinch experiment on the high current S-300 generator the aluminium line spectrum was registered with nanosecond time resolution. The simultaneous appearance of [He]- and [H]-like aluminium ions radiation was observed, that is the evidence of high electron temperature existence in the plasma for a long time before the main part of the load mass comes to the axis. The noticeably changing of radiating plasma parameters was found after the computer treatment of line spectra: the electron concentration is varied in five times ((3…14)×10^19 cm^-3), electron temperature in three times (0.3…1 keV), ion temperature in five times (20…100 keV), – during 50 ns. The great difference between the electron and ion temperature holds during all radiation time and demonstrates the ineffective energy transfer from the kinetic energy of ions to electron. Разработана методика для регистрации с временным разрешением рентгеновских линий [He]- и [H]-подобных ионов алюминия. Рентгеновский спектр преобразовывался с помощью сцинтиллятора в видимое изображение, которое переносилось гибким световодом на входную щель электронно-оптического преобразователя. Регистрация спектра проводилась с наносекундным разрешением в экспериментах с Z-пинчем на сильноточном генераторе С-300. Наблюдалось одновременное появление линий [He]- и [H]-подобных ионов алюминия, что является свидетельством наличия высокой электронной температуры в плазме задолго до момента прихода к оси основной массы Z-пинча. Компьютерная обработка спектров выявила значительные изменения параметров плазмы в процессе сжатия: концентрации в пять раз ((3…14)×10^19 см^-3), электронной температуры в три (0.3…1 кэВ), ионной температуры в пять раз (20…100 кэВ) – за 50 нс. Большой разрыв между ионной и электронной температурами демонстрирует неэффективность передачи энергии от ионов к электронам. Розроблено методику для реєстрації з часовим дозволом рентгенівських ліній [He]- і [H]-подібних іонів алюмінію. Рентгенівський спектр перетворювався за допомогою сцинтиллятора у видиме зображення, що переносилося гнучким світловодом на вхідну щілину електронно-оптичного перетворювача. Реєстрація спектра проводилася з наносекундним дозволом в експериментах з Z-пінчем на потужнострумовому генераторі С-300. Спостерігалася одночасна поява ліній [He]- і [H]-подібних іонів алюмінію, що є свідченням наявності високої електронної температури в плазмі задовго до моменту приходу до осі основної маси Z-пінча. Комп'ютерна обробка спектрів виявила значні зміни параметрів плазми в процесі стиску: концентрації в п'ять разів ((3...14)×10^19см^-3), електронної температури в три (0.3...1кеВ), іонної температури в п'ять разів (20...100 кеВ) – за 50 нс. Великий розрив між іонною й електронною температурами демонструє неефективність передачі енергії від іонів до електронів. This work was supported by grants of RFBR 08-02-01102 and НШ-6536.2010.2. 2010 Article X-ray line spectrometry in experiments with the aluminium Z-pinch / S.S. Anan’ev, S.A. Dan’ko, Yu.G. Kalinin, Fan Ye, Yi Qin, Shuqing Jiang, Feibiao Xue, Zhenghong Li, Jianlun Yang, Rongkun Xu // Вопросы атомной науки и техники. — 2010. — № 6. — С. 205-207. — Бібліогр.: 11 назв. — англ. 1562-6016 https://nasplib.isofts.kiev.ua/handle/123456789/17505 en application/pdf Національний науковий центр «Харківський фізико-технічний інститут» НАН України
institution Digital Library of Periodicals of National Academy of Sciences of Ukraine
collection DSpace DC
language English
topic Диагностика плазмы
Диагностика плазмы
spellingShingle Диагностика плазмы
Диагностика плазмы
Anan’ev, S.S.
Dan’ko, S.A.
Kalinin, Yu.G.
Ye Fan
Qin Yi
Jiang Shuqing
Xue Feibiao
Li Zhenghong
Yang Jianlun
Xu Rongkun
X-ray line spectrometry in experiments with the aluminium Z-pinch
description X-ray line spectrometry with temporal resolution was developed for registration of [He]- and [H]-like aluminium ions spectrum. It was chosen a scheme with scintillator converting X-ray spectrum into the visible image, which was transferred through the flexible optical fiber to the entrance slit of the streak camera. In Z-pinch experiment on the high current S-300 generator the aluminium line spectrum was registered with nanosecond time resolution. The simultaneous appearance of [He]- and [H]-like aluminium ions radiation was observed, that is the evidence of high electron temperature existence in the plasma for a long time before the main part of the load mass comes to the axis. The noticeably changing of radiating plasma parameters was found after the computer treatment of line spectra: the electron concentration is varied in five times ((3…14)×10^19 cm^-3), electron temperature in three times (0.3…1 keV), ion temperature in five times (20…100 keV), – during 50 ns. The great difference between the electron and ion temperature holds during all radiation time and demonstrates the ineffective energy transfer from the kinetic energy of ions to electron.
format Article
author Anan’ev, S.S.
Dan’ko, S.A.
Kalinin, Yu.G.
Ye Fan
Qin Yi
Jiang Shuqing
Xue Feibiao
Li Zhenghong
Yang Jianlun
Xu Rongkun
author_facet Anan’ev, S.S.
Dan’ko, S.A.
Kalinin, Yu.G.
Ye Fan
Qin Yi
Jiang Shuqing
Xue Feibiao
Li Zhenghong
Yang Jianlun
Xu Rongkun
author_sort Anan’ev, S.S.
title X-ray line spectrometry in experiments with the aluminium Z-pinch
title_short X-ray line spectrometry in experiments with the aluminium Z-pinch
title_full X-ray line spectrometry in experiments with the aluminium Z-pinch
title_fullStr X-ray line spectrometry in experiments with the aluminium Z-pinch
title_full_unstemmed X-ray line spectrometry in experiments with the aluminium Z-pinch
title_sort x-ray line spectrometry in experiments with the aluminium z-pinch
publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України
publishDate 2010
topic_facet Диагностика плазмы
url https://nasplib.isofts.kiev.ua/handle/123456789/17505
citation_txt X-ray line spectrometry in experiments with the aluminium Z-pinch / S.S. Anan’ev, S.A. Dan’ko, Yu.G. Kalinin, Fan Ye, Yi Qin, Shuqing Jiang, Feibiao Xue, Zhenghong Li, Jianlun Yang, Rongkun Xu // Вопросы атомной науки и техники. — 2010. — № 6. — С. 205-207. — Бібліогр.: 11 назв. — англ.
work_keys_str_mv AT ananevss xraylinespectrometryinexperimentswiththealuminiumzpinch
AT dankosa xraylinespectrometryinexperimentswiththealuminiumzpinch
AT kalininyug xraylinespectrometryinexperimentswiththealuminiumzpinch
AT yefan xraylinespectrometryinexperimentswiththealuminiumzpinch
AT qinyi xraylinespectrometryinexperimentswiththealuminiumzpinch
AT jiangshuqing xraylinespectrometryinexperimentswiththealuminiumzpinch
AT xuefeibiao xraylinespectrometryinexperimentswiththealuminiumzpinch
AT lizhenghong xraylinespectrometryinexperimentswiththealuminiumzpinch
AT yangjianlun xraylinespectrometryinexperimentswiththealuminiumzpinch
AT xurongkun xraylinespectrometryinexperimentswiththealuminiumzpinch
AT ananevss spektrometriârentgenovskihlinijvéksperimentahsalûminievymzpinčem
AT dankosa spektrometriârentgenovskihlinijvéksperimentahsalûminievymzpinčem
AT kalininyug spektrometriârentgenovskihlinijvéksperimentahsalûminievymzpinčem
AT yefan spektrometriârentgenovskihlinijvéksperimentahsalûminievymzpinčem
AT qinyi spektrometriârentgenovskihlinijvéksperimentahsalûminievymzpinčem
AT jiangshuqing spektrometriârentgenovskihlinijvéksperimentahsalûminievymzpinčem
AT xuefeibiao spektrometriârentgenovskihlinijvéksperimentahsalûminievymzpinčem
AT lizhenghong spektrometriârentgenovskihlinijvéksperimentahsalûminievymzpinčem
AT yangjianlun spektrometriârentgenovskihlinijvéksperimentahsalûminievymzpinčem
AT xurongkun spektrometriârentgenovskihlinijvéksperimentahsalûminievymzpinčem
AT ananevss spektrometríârentgenívsʹkihlíníjveksperimentahzalûmíníêvimzpínčem
AT dankosa spektrometríârentgenívsʹkihlíníjveksperimentahzalûmíníêvimzpínčem
AT kalininyug spektrometríârentgenívsʹkihlíníjveksperimentahzalûmíníêvimzpínčem
AT yefan spektrometríârentgenívsʹkihlíníjveksperimentahzalûmíníêvimzpínčem
AT qinyi spektrometríârentgenívsʹkihlíníjveksperimentahzalûmíníêvimzpínčem
AT jiangshuqing spektrometríârentgenívsʹkihlíníjveksperimentahzalûmíníêvimzpínčem
AT xuefeibiao spektrometríârentgenívsʹkihlíníjveksperimentahzalûmíníêvimzpínčem
AT lizhenghong spektrometríârentgenívsʹkihlíníjveksperimentahzalûmíníêvimzpínčem
AT yangjianlun spektrometríârentgenívsʹkihlíníjveksperimentahzalûmíníêvimzpínčem
AT xurongkun spektrometríârentgenívsʹkihlíníjveksperimentahzalûmíníêvimzpínčem
first_indexed 2025-11-24T11:46:45Z
last_indexed 2025-11-24T11:46:45Z
_version_ 1849672131803086848