An active charge –exchange q measurements in ITER based upon the diagnostic hydrogen beam
The active charge exchange technique based upon Secondary Charge Exchange effect (SCX) is proposed for
 safety factor measurements in ITER. The performed numerical modeling shows that measurements of the magnetic
 pitch angle are possible up to the plasma center with radial resolutio...