Криоконсервирование кордовой крови с использованием ПЭО-1500

The method without washing-out for the whole cord blood cryopreservation with PEO-1500, enabling to preserve up to 99 and 93% erythrocytes after freeze-thawing and by the transfusion test data, correspondingly, has been designed. The integrity of biologically active substances in plasm at the contro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Datum:2007
Hauptverfasser: Ryazantsev, V. V., Babijchuk, L. A., Zubova, O. L., Gurina, T. M.
Format: Artikel
Sprache:English
Veröffentlicht: Publishing House ‘Akademperiodyka’ of the National Academy of Sciences of Ukraine; Institute for Problems of Cryobiology and Cryomedicine 2007
Schlagworte:
Online Zugang:https://cryo.org.ua/journal/index.php/probl-cryobiol-cryomed/article/view/497
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Назва журналу:Problems of Cryobiology and Cryomedicine

Institution

Problems of Cryobiology and Cryomedicine
Beschreibung
Zusammenfassung:The method without washing-out for the whole cord blood cryopreservation with PEO-1500, enabling to preserve up to 99 and 93% erythrocytes after freeze-thawing and by the transfusion test data, correspondingly, has been designed. The integrity of biologically active substances in plasm at the control level has been established. After cryopreservation with the mentioned above method the immunofluorescent test has demonstrated the integrity of up to 70% blood lymphocytes, including cord blood stem cells (CD34+).